64409eeee7
This will help application developers simulate end of tape conditions. To inject an error in sa0: sysctl kern.cam.sa.0.inject_eom=1 This will return the next read or write request queued with 0 bytes written. Any subsequent writes or reads will go along as usual. This will also cause the early warning position flag to get set for the next position query. So, 'mt status' will show the BPEW (Beyond Programmable Early Warning) flag on the first query after an error injection. After that, the position flags will be as they are in the underlying tape drive. Also, update the sa(4) man page to describe tape parameters, which can be set via 'mt param'. sys/cam/scsi/scsi_sa.c: In saregister(), create the inject_eom sysctl variable. In sastart(), check to see whether inject_eom is set. If so, return the read or write with 0 bytes written to indicate EOM. Set the set_pews_status flag so that we fake PEWS status in the next position call for reads, and the next 3 calls for writes. This allows the user to see the BPEW flag one time via 'mt status'. In sagetpos(), check the set_pews_status flag and fake PEWS status and decrement the counter if it is set. share/man/man4/sa.4: Document the inject_eom sysctl variable. Document all of the parameters currently supported via 'mt param'. usr.bin/mt/mt.1: Point the user to the sa(4) man page for more details on supported parameters. MFC after: 3 days Sponsored by: Spectra Logic |
||
---|---|---|
.. | ||
man1 | ||
man3 | ||
man4 | ||
man5 | ||
man6 | ||
man7 | ||
man8 | ||
man9 | ||
Makefile |