6d341cc8f0
Previously we would check for blessings before marking a given lock pair as reversed, so each "reversed" lock acquisition would require a linear scan of the table. Instead, check the table after marking the pair as reversed but before generating a report. Reviewed by: jhb MFC after: 1 week Sponsored by: The FreeBSD Foundation Differential Revision: https://reviews.freebsd.org/D21135