193a6144b9
o Properly use rman(9) to manage resources. This eliminates the need to puc-specific hacks to rman. It also allows devinfo(8) to be used to find out the specific assignment of resources to serial/parallel ports. o Compress the PCI device "database" by optimizing for the common case and to use a procedural interface to handle the exceptions. The procedural interface also generalizes the need to setup the hardware (program chipsets, program clock frequencies). o Eliminate the need for PUC_FASTINTR. Serdev devices are fast by default and non-serdev devices are handled by the bus. o Use the serdev I/F to collect interrupt status and to handle interrupts across ports in priority order. o Sync the PCI device configuration to include devices found in NetBSD and not yet merged to FreeBSD. o Add support for Quatech 2, 4 and 8 port UARTs. o Add support for a couple dozen Timedia serial cards as found in Linux.
176 lines
4.2 KiB
C
176 lines
4.2 KiB
C
/*-
|
|
* Copyright (c) 2006 Marcel Moolenaar
|
|
* All rights reserved.
|
|
*
|
|
* Redistribution and use in source and binary forms, with or without
|
|
* modification, are permitted provided that the following conditions
|
|
* are met:
|
|
*
|
|
* 1. Redistributions of source code must retain the above copyright
|
|
* notice, this list of conditions and the following disclaimer.
|
|
* 2. Redistributions in binary form must reproduce the above copyright
|
|
* notice, this list of conditions and the following disclaimer in the
|
|
* documentation and/or other materials provided with the distribution.
|
|
*
|
|
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
|
|
* IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
|
|
* OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
|
|
* IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
|
|
* INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
|
|
* NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
|
|
* DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
|
|
* THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
|
* (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
|
|
* THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
*/
|
|
|
|
#include <sys/cdefs.h>
|
|
__FBSDID("$FreeBSD$");
|
|
|
|
#include <sys/param.h>
|
|
#include <sys/systm.h>
|
|
#include <sys/bus.h>
|
|
#include <sys/rman.h>
|
|
|
|
#include <dev/puc/puc_bfe.h>
|
|
#include <dev/puc/puc_bus.h>
|
|
#include <dev/puc/puc_cfg.h>
|
|
|
|
int
|
|
puc_config(struct puc_softc *sc, enum puc_cfg_cmd cmd, int port, intptr_t *r)
|
|
{
|
|
const struct puc_cfg *cfg = sc->sc_cfg;
|
|
int error;
|
|
|
|
if (cfg->config_function != NULL) {
|
|
error = cfg->config_function(sc, cmd, port, r);
|
|
if (!error)
|
|
return (0);
|
|
} else
|
|
error = EDOOFUS;
|
|
|
|
switch (cmd) {
|
|
case PUC_CFG_GET_CLOCK:
|
|
if (cfg->clock < 0)
|
|
return (error);
|
|
*r = cfg->clock;
|
|
return (0);
|
|
case PUC_CFG_GET_DESC:
|
|
if (cfg->desc == NULL)
|
|
return (error);
|
|
*r = (intptr_t)cfg->desc;
|
|
return (0);
|
|
case PUC_CFG_GET_ILR:
|
|
*r = PUC_ILR_NONE;
|
|
return (0);
|
|
case PUC_CFG_GET_LEN:
|
|
/* The length of bus space needed by the port. */
|
|
*r = 8;
|
|
return (0);
|
|
case PUC_CFG_GET_NPORTS:
|
|
/* The number of ports on this card. */
|
|
switch (cfg->ports) {
|
|
case PUC_PORT_NONSTANDARD:
|
|
return (error);
|
|
case PUC_PORT_1P:
|
|
case PUC_PORT_1S:
|
|
*r = 1;
|
|
return (0);
|
|
case PUC_PORT_1S1P:
|
|
case PUC_PORT_2P:
|
|
case PUC_PORT_2S:
|
|
*r = 2;
|
|
return (0);
|
|
case PUC_PORT_1S2P:
|
|
case PUC_PORT_2S1P:
|
|
case PUC_PORT_3S:
|
|
*r = 3;
|
|
return (0);
|
|
case PUC_PORT_4S:
|
|
*r = 4;
|
|
return (0);
|
|
case PUC_PORT_4S1P:
|
|
*r = 5;
|
|
return (0);
|
|
case PUC_PORT_6S:
|
|
*r = 6;
|
|
return (0);
|
|
case PUC_PORT_8S:
|
|
*r = 8;
|
|
return (0);
|
|
case PUC_PORT_12S:
|
|
*r = 12;
|
|
return (0);
|
|
case PUC_PORT_16S:
|
|
*r = 16;
|
|
return (0);
|
|
}
|
|
break;
|
|
case PUC_CFG_GET_OFS:
|
|
/* The offset relative to the RID. */
|
|
if (cfg->d_ofs < 0)
|
|
return (error);
|
|
*r = port * cfg->d_ofs;
|
|
return (0);
|
|
case PUC_CFG_GET_RID:
|
|
/* The RID for this port. */
|
|
if (port == 0) {
|
|
if (cfg->rid < 0)
|
|
return (error);
|
|
*r = cfg->rid;
|
|
return (0);
|
|
}
|
|
if (cfg->d_rid < 0)
|
|
return (error);
|
|
if (cfg->rid < 0) {
|
|
error = puc_config(sc, PUC_CFG_GET_RID, 0, r);
|
|
if (error)
|
|
return (error);
|
|
} else
|
|
*r = cfg->rid;
|
|
*r += port * cfg->d_rid;
|
|
return (0);
|
|
case PUC_CFG_GET_TYPE:
|
|
/* The type of this port. */
|
|
if (cfg->ports == PUC_PORT_NONSTANDARD)
|
|
return (error);
|
|
switch (port) {
|
|
case 0:
|
|
if (cfg->ports == PUC_PORT_1P ||
|
|
cfg->ports == PUC_PORT_2P)
|
|
*r = PUC_TYPE_PARALLEL;
|
|
else
|
|
*r = PUC_TYPE_SERIAL;
|
|
return (0);
|
|
case 1:
|
|
if (cfg->ports == PUC_PORT_1S1P ||
|
|
cfg->ports == PUC_PORT_1S2P ||
|
|
cfg->ports == PUC_PORT_2P)
|
|
*r = PUC_TYPE_PARALLEL;
|
|
else
|
|
*r = PUC_TYPE_SERIAL;
|
|
return (0);
|
|
case 2:
|
|
if (cfg->ports == PUC_PORT_1S2P ||
|
|
cfg->ports == PUC_PORT_2S1P)
|
|
*r = PUC_TYPE_PARALLEL;
|
|
else
|
|
*r = PUC_TYPE_SERIAL;
|
|
return (0);
|
|
case 4:
|
|
if (cfg->ports == PUC_PORT_4S1P)
|
|
*r = PUC_TYPE_PARALLEL;
|
|
else
|
|
*r = PUC_TYPE_SERIAL;
|
|
return (0);
|
|
}
|
|
*r = PUC_TYPE_SERIAL;
|
|
return (0);
|
|
case PUC_CFG_SETUP:
|
|
*r = ENXIO;
|
|
return (0);
|
|
}
|
|
|
|
return (ENXIO);
|
|
}
|