.\" Copyright (c) 2003 Robert N. M. Watson
|
|
.\" All rights reserved.
|
|
.\"
|
|
.\" Redistribution and use in source and binary forms, with or without
|
|
.\" modification, are permitted provided that the following conditions
|
|
.\" are met:
|
|
.\" 1. Redistributions of source code must retain the above copyright
|
|
.\" notice(s), this list of conditions and the following disclaimer as
|
|
.\" the first lines of this file unmodified other than the possible
|
|
.\" addition of one or more copyright notices.
|
|
.\" 2. Redistributions in binary form must reproduce the above copyright
|
|
.\" notice(s), this list of conditions and the following disclaimer in the
|
|
.\" documentation and/or other materials provided with the distribution.
|
|
.\"
|
|
.\" THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDER(S) ``AS IS'' AND ANY
|
|
.\" EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
|
|
.\" WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
|
|
.\" DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER(S) BE LIABLE FOR ANY
|
|
.\" DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES
|
|
.\" (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
|
|
.\" SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
|
|
.\" CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH
|
|
.\" DAMAGE.
|
|
.\"
|
|
.\" $FreeBSD$
|
|
.\"
|
|
.Dd October 30, 2012
|
|
.Dt DISK 9
|
|
.Os
|
|
.Sh NAME
|
|
.Nm disk
|
|
.Nd kernel disk storage API
|
|
.Sh SYNOPSIS
|
|
.In geom/geom_disk.h
|
|
.Ft struct disk *
|
|
.Fn disk_alloc void
|
|
.Ft void
|
|
.Fn disk_create "struct disk *disk" "int version"
|
|
.Ft void
|
|
.Fn disk_gone "struct disk *disk"
|
|
.Ft void
|
|
.Fn disk_destroy "struct disk *disk"
|
|
.Ft int
|
|
.Fn disk_resize "struct disk *disk" "int flags"
|
|
.Sh DESCRIPTION
|
|
The disk storage API permits kernel device drivers providing access to
|
|
disk-like storage devices to advertise the device to other kernel
|
|
components, including
|
|
.Xr GEOM 4
|
|
and
|
|
.Xr devfs 5 .
|
|
.Pp
|
|
Each disk device is described by a
|
|
.Vt "struct disk"
|
|
structure, which contains a variety of parameters for the disk device,
|
|
function pointers for various methods that may be performed on the device,
|
|
as well as private data storage for the device driver.
|
|
In addition, some fields are reserved for use by GEOM in managing access
|
|
to the device and its statistics.
|
|
.Pp
|
|
GEOM has the ownership of
|
|
.Vt "struct disk" ,
|
|
and drivers must allocate storage for it with the
|
|
.Fn disk_alloc
|
|
function,
|
|
fill in the fields and call
|
|
.Fn disk_create
|
|
when the device is ready to service requests.
|
|
.Fn disk_resize
|
|
can be called by the driver after modifying
|
|
.Va d_mediasize
|
|
to notify GEOM about the disk capacity change.
|
|
The
|
|
.Fa flags
|
|
field should be set to either M_WAITOK, or M_NOWAIT.
|
|
.Fn disk_gone
|
|
orphans all of the providers associated with the drive, setting an error
|
|
condition of ENXIO in each one.
|
|
In addition, it prevents a re-taste on last close for writing if an error
|
|
condition has been set in the provider.
|
|
After calling
|
|
.Fn disk_destroy ,
|
|
the device driver is not allowed to access the contents of
|
|
.Vt "struct disk"
|
|
anymore.
|
|
.Pp
|
|
The
|
|
.Fn disk_create
|
|
function
|
|
takes a second parameter,
|
|
.Fa version ,
|
|
which must always be passed
|
|
.Dv DISK_VERSION .
|
|
If GEOM detects that the driver is compiled against an unsupported version,
|
|
it will ignore the device and print a warning on the console.
|
|
.Ss Descriptive Fields
|
|
The following fields identify the disk device described by the structure
|
|
instance, and must be filled in prior to submitting the structure to
|
|
.Fn disk_create
|
|
and may not be subsequently changed:
|
|
.Bl -tag -width indent
|
|
.It Vt u_int Va d_flags
|
|
Optional flags indicating to the storage framework what optional features
|
|
or descriptions the storage device driver supports.
|
|
Currently supported flags are
|
|
.Dv DISKFLAG_OPEN
|
|
(maintained by storage framework),
|
|
.Dv DISKFLAG_CANDELETE
|
|
(maintained by device driver),
|
|
and
|
|
.Dv DISKFLAG_CANFLUSHCACHE
|
|
(maintained by device driver).
|
|
.It Vt "const char *" Va d_name
|
|
Holds the name of the storage device class, e.g.,
|
|
.Dq Li ahd .
|
|
This value typically uniquely identifies a particular driver device,
|
|
and must not conflict with devices serviced by other device drivers.
|
|
.It Vt u_int Va d_unit
|
|
Holds the instance of the storage device class, e.g.,
|
|
.Dq Li 4 .
|
|
This namespace is managed by the device driver, and assignment of unit
|
|
numbers might be a property of probe order, or in some cases topology.
|
|
Together, the
|
|
.Va d_name
|
|
and
|
|
.Va d_unit
|
|
values will uniquely identify a disk storage device.
|
|
.El
|
|
.Ss Disk Device Methods
|
|
The following fields identify various disk device methods, if implemented:
|
|
.Bl -tag -width indent
|
|
.It Vt "disk_open_t *" Va d_open
|
|
Optional: invoked when the disk device is opened.
|
|
If no method is provided, open will always succeed.
|
|
.It Vt "disk_close_t *" Va d_close
|
|
Optional: invoked when the disk device is closed.
|
|
Although an error code may be returned, the call should always terminate
|
|
any state setup by the corresponding open method call.
|
|
.It Vt "disk_strategy_t *" Va d_strategy
|
|
Mandatory: invoked when a new
|
|
.Vt "struct bio"
|
|
is to be initiated on the disk device.
|
|
.It Vt "disk_ioctl_t *" Va d_ioctl
|
|
Optional: invoked when an I/O control operation is initiated on the disk device.
|
|
Please note that for security reasons these operations should not
|
|
be able to affect other devices than the one on which they are performed.
|
|
.It Vt "dumper_t *" Va d_dump
|
|
Optional: if configured with
|
|
.Xr dumpon 8 ,
|
|
this function is invoked from a very restricted system state after a
|
|
kernel panic to record a copy of the system RAM to the disk.
|
|
.It Vt "disk_getattr_t *" Va d_getattr
|
|
Optional: if this method is provided, it gives the disk driver the
|
|
opportunity to override the default GEOM response to BIO_GETATTR requests.
|
|
This function should return -1 if the attribute is not handled, 0 if the
|
|
attribute is handled, or an errno to be passed to g_io_deliver().
|
|
.It Vt "disk_gone_t *" Va d_gone
|
|
Optional: if this method is provided, it will be called after disk_gone()
|
|
is called, once GEOM has finished its cleanup process.
|
|
Once this callback is called, it is safe for the disk driver to free all of
|
|
its resources, as it will not be receiving further calls from GEOM.
|
|
.El
|
|
.Ss Mandatory Media Properties
|
|
The following fields identify the size and granularity of the disk device.
|
|
These fields must stay stable from return of the drivers open method until
|
|
the close method is called, but it is perfectly legal to modify them in
|
|
the open method before returning.
|
|
.Bl -tag -width indent
|
|
.It Vt u_int Va d_sectorsize
|
|
The sector size of the disk device in bytes.
|
|
.It Vt off_t Va d_mediasize
|
|
The size of the disk device in bytes.
|
|
.It Vt u_int Va d_maxsize
|
|
The maximum supported size in bytes of an I/O request.
|
|
Requests larger than this size will be chopped up by GEOM.
|
|
.El
|
|
.Ss Optional Media Properties
|
|
These optional fields can provide extra information about the disk
|
|
device.
|
|
Do not initialize these fields if the field/concept does not apply.
|
|
These fields must stay stable from return of the drivers open method until
|
|
the close method is called, but it is perfectly legal to modify them in
|
|
the open method before returning.
|
|
.Bl -tag -width indent
|
|
.It Vt u_int Va d_fwsectors , Vt u_int Va d_fwheads
|
|
The number of sectors and heads advertised on the disk device by the
|
|
firmware or BIOS.
|
|
These values are almost universally bogus, but on some architectures
|
|
necessary for the correct calculation of disk partitioning.
|
|
.It Vt u_int Va d_stripeoffset , Vt u_int Va d_stripesize
|
|
These two fields can be used to describe the width and location of
|
|
natural performance boundaries for most disk technologies.
|
|
Please see
|
|
.Pa src/sys/geom/notes
|
|
for details.
|
|
.It Vt char Va d_ident[DISK_IDENT_SIZE]
|
|
This field can and should be used to store disk's serial number if the
|
|
d_getattr method described above isn't implemented, or if it does not
|
|
support the GEOM::ident attribute.
|
|
.It Vt char Va d_descr[DISK_IDENT_SIZE]
|
|
This field can be used to store the disk vendor and product description.
|
|
.It Vt uint16_t Va d_hba_vendor
|
|
This field can be used to store the PCI vendor ID for the HBA connected to
|
|
the disk.
|
|
.It Vt uint16_t Va d_hba_device
|
|
This field can be used to store the PCI device ID for the HBA connected to
|
|
the disk.
|
|
.It Vt uint16_t Va d_hba_subvendor
|
|
This field can be used to store the PCI subvendor ID for the HBA connected to
|
|
the disk.
|
|
.It Vt uint16_t Va d_hba_subdevice
|
|
This field can be used to store the PCI subdevice ID for the HBA connected to
|
|
the disk.
|
|
.El
|
|
.Ss Driver Private Data
|
|
This field may be used by the device driver to store a pointer to
|
|
private data to implement the disk service.
|
|
.Bl -tag -width indent
|
|
.It Vt "void *" Va d_drv1
|
|
Private data pointer.
|
|
Typically used to store a pointer to the drivers
|
|
.Vt softc
|
|
structure for this disk device.
|
|
.El
|
|
.Sh SEE ALSO
|
|
.Xr GEOM 4 ,
|
|
.Xr devfs 5
|
|
.Sh AUTHORS
|
|
This manual page was written by
|
|
.An Robert Watson .
|