77185f473b
members, thus making a signed extension of 32 bit register context. If the register is not touched in usermode between return from signal and next syscall entry, the sign-extension part of 64bit register is not cleared, causing linux32_fetch_syscall_args() to read wrong values. Use unsigned type for the registers in the linux sigcontext. Reported by: Jacob Frelinger <jacob.frelinger duke edu>, arundel In collaboration with: dchagin MFC after: 1 week