freebsd-skq/sys/dev/coretemp
Luiz Otavio O Souza 9d6672e13b Fix the deciKelvin to Celsius conversion in kernel.
After r285994, sysctl(8) was fixed to use 273.15 instead of 273.20 as 0C
reference and as result, the temperature read in sysctl(8) now exibits a
+0.1C difference.

This commit fix the kernel references to match the reference value used in
sysctl(8) after r285994.

Sponsored by:	Rubicon Communications (Netgate)
2016-05-22 13:58:32 +00:00
..
coretemp.c Fix the deciKelvin to Celsius conversion in kernel. 2016-05-22 13:58:32 +00:00