a82e3a8b24
Mainly focus on files that use BSD 2-Clause license, however the tool I was using misidentified many licenses so this was mostly a manual - error prone - task. The Software Package Data Exchange (SPDX) group provides a specification to make it easier for automated tools to detect and summarize well known opensource licenses. We are gradually adopting the specification, noting that the tags are considered only advisory and do not, in any way, superceed or replace the license texts.
191 lines
5.5 KiB
C
191 lines
5.5 KiB
C
/*-
|
|
* SPDX-License-Identifier: BSD-2-Clause-FreeBSD
|
|
*
|
|
* Copyright (c) 2005 Chris Jones
|
|
* All rights reserved.
|
|
*
|
|
* This software was developed for the FreeBSD Project by Chris Jones
|
|
* thanks to the support of Google's Summer of Code program and
|
|
* mentoring by Lukas Ertl.
|
|
*
|
|
* Redistribution and use in source and binary forms, with or without
|
|
* modification, are permitted provided that the following conditions
|
|
* are met:
|
|
* 1. Redistributions of source code must retain the above copyright
|
|
* notice, this list of conditions and the following disclaimer.
|
|
* 2. Redistributions in binary form must reproduce the above copyright
|
|
* notice, this list of conditions and the following disclaimer in the
|
|
* documentation and/or other materials provided with the distribution.
|
|
*
|
|
* THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
|
|
* ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
|
* IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
|
* ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
|
|
* FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
|
* DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
|
* OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
|
* HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
|
* LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
|
* OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
* SUCH DAMAGE.
|
|
*
|
|
*/
|
|
|
|
#include <sys/cdefs.h>
|
|
__FBSDID("$FreeBSD$");
|
|
|
|
#include <sys/libkern.h>
|
|
#include <sys/malloc.h>
|
|
|
|
#include <geom/geom.h>
|
|
#include <geom/vinum/geom_vinum_var.h>
|
|
#include <geom/vinum/geom_vinum.h>
|
|
|
|
void
|
|
gv_move(struct g_geom *gp, struct gctl_req *req)
|
|
{
|
|
struct gv_softc *sc;
|
|
struct gv_sd *s;
|
|
struct gv_drive *d;
|
|
char buf[20], *destination, *object;
|
|
int *argc, *flags, i, type;
|
|
|
|
sc = gp->softc;
|
|
|
|
argc = gctl_get_paraml(req, "argc", sizeof(*argc));
|
|
if (argc == NULL) {
|
|
gctl_error(req, "no arguments given");
|
|
return;
|
|
}
|
|
flags = gctl_get_paraml(req, "flags", sizeof(*flags));
|
|
if (flags == NULL) {
|
|
gctl_error(req, "no flags given");
|
|
return;
|
|
}
|
|
destination = gctl_get_param(req, "destination", NULL);
|
|
if (destination == NULL) {
|
|
gctl_error(req, "no destination given");
|
|
return;
|
|
}
|
|
if (gv_object_type(sc, destination) != GV_TYPE_DRIVE) {
|
|
gctl_error(req, "destination '%s' is not a drive", destination);
|
|
return;
|
|
}
|
|
d = gv_find_drive(sc, destination);
|
|
|
|
/*
|
|
* We start with 1 here, because argv[0] on the command line is the
|
|
* destination drive.
|
|
*/
|
|
for (i = 1; i < *argc; i++) {
|
|
snprintf(buf, sizeof(buf), "argv%d", i);
|
|
object = gctl_get_param(req, buf, NULL);
|
|
if (object == NULL)
|
|
continue;
|
|
|
|
type = gv_object_type(sc, object);
|
|
if (type != GV_TYPE_SD) {
|
|
gctl_error(req, "you can only move subdisks; "
|
|
"'%s' is not a subdisk", object);
|
|
return;
|
|
}
|
|
|
|
s = gv_find_sd(sc, object);
|
|
if (s == NULL) {
|
|
gctl_error(req, "unknown subdisk '%s'", object);
|
|
return;
|
|
}
|
|
gv_post_event(sc, GV_EVENT_MOVE_SD, s, d, *flags, 0);
|
|
}
|
|
}
|
|
|
|
/* Move a subdisk. */
|
|
int
|
|
gv_move_sd(struct gv_softc *sc, struct gv_sd *cursd,
|
|
struct gv_drive *destination, int flags)
|
|
{
|
|
struct gv_drive *d;
|
|
struct gv_sd *newsd, *s, *s2;
|
|
struct gv_plex *p;
|
|
int err;
|
|
|
|
g_topology_assert();
|
|
KASSERT(cursd != NULL, ("gv_move_sd: NULL cursd"));
|
|
KASSERT(destination != NULL, ("gv_move_sd: NULL destination"));
|
|
|
|
d = cursd->drive_sc;
|
|
|
|
if ((gv_consumer_is_open(d->consumer) ||
|
|
gv_consumer_is_open(destination->consumer)) &&
|
|
!(flags & GV_FLAG_F)) {
|
|
G_VINUM_DEBUG(0, "consumers on current and destination drive "
|
|
" still open");
|
|
return (GV_ERR_ISBUSY);
|
|
}
|
|
|
|
if (!(flags & GV_FLAG_F)) {
|
|
G_VINUM_DEBUG(1, "-f flag not passed; move would be "
|
|
"destructive");
|
|
return (GV_ERR_INVFLAG);
|
|
}
|
|
|
|
if (destination == cursd->drive_sc) {
|
|
G_VINUM_DEBUG(1, "subdisk '%s' already on drive '%s'",
|
|
cursd->name, destination->name);
|
|
return (GV_ERR_ISATTACHED);
|
|
}
|
|
|
|
/* XXX: Does it have to be part of a plex? */
|
|
p = gv_find_plex(sc, cursd->plex);
|
|
if (p == NULL) {
|
|
G_VINUM_DEBUG(0, "subdisk '%s' is not part of a plex",
|
|
cursd->name);
|
|
return (GV_ERR_NOTFOUND);
|
|
}
|
|
|
|
/* Stale the old subdisk. */
|
|
err = gv_set_sd_state(cursd, GV_SD_STALE,
|
|
GV_SETSTATE_FORCE | GV_SETSTATE_CONFIG);
|
|
if (err) {
|
|
G_VINUM_DEBUG(0, "unable to set the subdisk '%s' to state "
|
|
"'stale'", cursd->name);
|
|
return (err);
|
|
}
|
|
|
|
/*
|
|
* Create new subdisk. Ideally, we'd use gv_new_sd, but that requires
|
|
* us to create a string for it to parse, which is silly.
|
|
* TODO: maybe refactor gv_new_sd such that this is no longer the case.
|
|
*/
|
|
newsd = g_malloc(sizeof(struct gv_sd), M_WAITOK | M_ZERO);
|
|
newsd->plex_offset = cursd->plex_offset;
|
|
newsd->size = cursd->size;
|
|
newsd->drive_offset = -1;
|
|
strlcpy(newsd->name, cursd->name, sizeof(newsd->name));
|
|
strlcpy(newsd->drive, destination->name, sizeof(newsd->drive));
|
|
strlcpy(newsd->plex, cursd->plex, sizeof(newsd->plex));
|
|
newsd->state = GV_SD_STALE;
|
|
newsd->vinumconf = cursd->vinumconf;
|
|
|
|
err = gv_sd_to_drive(newsd, destination);
|
|
if (err) {
|
|
/* XXX not enough free space? */
|
|
g_free(newsd);
|
|
return (err);
|
|
}
|
|
|
|
/* Replace the old sd by the new one. */
|
|
LIST_FOREACH_SAFE(s, &p->subdisks, in_plex, s2) {
|
|
if (s == cursd) {
|
|
gv_rm_sd(sc, s);
|
|
}
|
|
}
|
|
gv_sd_to_plex(newsd, p);
|
|
LIST_INSERT_HEAD(&sc->subdisks, newsd, sd);
|
|
/* Update volume size of plex. */
|
|
if (p->vol_sc != NULL)
|
|
gv_update_vol_size(p->vol_sc, gv_vol_size(p->vol_sc));
|
|
gv_save_config(p->vinumconf);
|
|
return (0);
|
|
}
|