6c89995002
PR: 191174 Submitted by: Franco Fichtner <franco at lastsummer.de>
254 lines
8.1 KiB
Groff
254 lines
8.1 KiB
Groff
.\"
|
|
.\" Copyright (c) 2003 David O'Brien
|
|
.\" Copyright (c) 2000 Jeroen Ruigrok van der Werven
|
|
.\" Copyright (c) 2000 Michael Smith
|
|
.\" All rights reserved.
|
|
.\"
|
|
.\" Redistribution and use in source and binary forms, with or without
|
|
.\" modification, are permitted provided that the following conditions
|
|
.\" are met:
|
|
.\" 1. Redistributions of source code must retain the above copyright
|
|
.\" notice, this list of conditions and the following disclaimer.
|
|
.\" 2. The name of the author may not be used to endorse or promote products
|
|
.\" derived from this software without specific prior written permission
|
|
.\"
|
|
.\" THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
|
|
.\" IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
|
|
.\" OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
|
|
.\" IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
|
|
.\" INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
|
|
.\" NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
|
|
.\" DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
|
|
.\" THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
|
.\" (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
|
|
.\" THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
.\"
|
|
.\" $FreeBSD$
|
|
.\"
|
|
.Dd August 10, 2004
|
|
.Dt MLX 4
|
|
.Os
|
|
.Sh NAME
|
|
.Nm mlx
|
|
.Nd Mylex DAC-family RAID driver
|
|
.Sh SYNOPSIS
|
|
To compile this driver into the kernel,
|
|
place the following lines in your
|
|
kernel configuration file:
|
|
.Bd -ragged -offset indent
|
|
.Cd "device pci"
|
|
.Cd "device mlx"
|
|
.Ed
|
|
.Pp
|
|
Alternatively, to load the driver as a
|
|
module at boot time, place the following line in
|
|
.Xr loader.conf 5 :
|
|
.Bd -literal -offset indent
|
|
mlx_load="YES"
|
|
.Ed
|
|
.Sh DESCRIPTION
|
|
The
|
|
.Nm
|
|
driver provides support for Mylex DAC-family PCI to SCSI RAID controllers,
|
|
including versions relabeled by Digital/Compaq.
|
|
.Sh HARDWARE
|
|
Controllers supported by the
|
|
.Nm
|
|
driver include:
|
|
.Pp
|
|
.Bl -bullet -compact
|
|
.It
|
|
Mylex DAC960P
|
|
.It
|
|
Mylex DAC960PD / DEC KZPSC (Fast Wide)
|
|
.It
|
|
Mylex DAC960PDU
|
|
.It
|
|
Mylex DAC960PL
|
|
.It
|
|
Mylex DAC960PJ
|
|
.It
|
|
Mylex DAC960PG
|
|
.It
|
|
Mylex DAC960PU / DEC PZPAC (Ultra Wide)
|
|
.It
|
|
Mylex AcceleRAID 150 (DAC960PRL)
|
|
.It
|
|
Mylex AcceleRAID 250 (DAC960PTL1)
|
|
.It
|
|
Mylex eXtremeRAID 1100 (DAC1164P)
|
|
.It
|
|
RAIDarray 230 controllers, aka the Ultra-SCSI DEC KZPAC-AA (1-ch, 4MB
|
|
cache), KZPAC-CA (3-ch, 4MB), KZPAC-CB (3-ch, 8MB cache)
|
|
.El
|
|
.Pp
|
|
All major firmware revisions (2.x, 3.x, 4.x and 5.x) are supported, however
|
|
it is always advisable to upgrade to the most recent firmware
|
|
available for the controller.
|
|
.Pp
|
|
Compatible Mylex controllers not listed should work, but have not been
|
|
verified.
|
|
.Sh DIAGNOSTICS
|
|
.Ss Controller initialisation phase
|
|
.Bl -diag
|
|
.It mlx%d: controller initialisation in progress...
|
|
.It mlx%d: initialisation complete
|
|
.Pp
|
|
The controller firmware is performing/has completed initialisation.
|
|
.It mlx%d: physical drive %d:%d not responding
|
|
.Pp
|
|
The drive at channel:target is not responding; it may have failed or
|
|
been removed.
|
|
.It mlx%d: spinning up drives...
|
|
.Pp
|
|
Drive startup is in progress; this may take several minutes.
|
|
.It mlx%d: configuration checksum error
|
|
.Pp
|
|
The array configuration has become corrupted.
|
|
.It mlx%d: mirror race recovery in progress
|
|
.It mlx%d: mirror race on a critical system drive
|
|
.It mlx%d: mirror race recovery failed
|
|
.Pp
|
|
These error codes are undocumented.
|
|
.It mlx%d: physical drive %d:%d COD mismatch
|
|
.Pp
|
|
Configuration data on the drive at channel:target does not match the
|
|
rest of the array.
|
|
.It mlx%d: system drive installation aborted
|
|
.Pp
|
|
Errors occurred preventing one or more system drives from being configured.
|
|
.It mlx%d: new controller configuration found
|
|
.Pp
|
|
The controller has detected a configuration on disk which supersedes the
|
|
configuration in its nonvolatile memory.
|
|
It will reset and come up with the new configuration.
|
|
.It mlx%d: FATAL MEMORY PARITY ERROR
|
|
.Pp
|
|
Firmware detected a fatal memory error; the driver will not attempt to
|
|
attach to this controller.
|
|
.It mlx%d: unknown firmware initialisation error %x:%x:%x
|
|
.Pp
|
|
An unknown error occurred during initialisation; it will be ignored.
|
|
.El
|
|
.Ss Driver initialisation/shutdown phase:
|
|
.Bl -diag
|
|
.It mlx%d: can't allocate scatter/gather DMA tag
|
|
.It mlx%d: can't allocate buffer DMA tag
|
|
.It mlx%d: can't allocate s/g table
|
|
.It mlx%d: can't make initial s/g list mapping
|
|
.It mlx%d: can't make permanent s/g list mapping
|
|
.It mlx%d: can't allocate interrupt
|
|
.It mlx%d: can't set up interrupt
|
|
.Pp
|
|
A resource allocation error occurred while initialising the driver;
|
|
initialisation has failed and the driver will not attach to this
|
|
controller.
|
|
.It mlx%d: error fetching drive status
|
|
.Pp
|
|
The current status of all system drives could not be fetched; attachment
|
|
of system drives will be aborted.
|
|
.It mlx%d: device_add_child failed
|
|
.It mlx%d: bus_generic_attach returned %d
|
|
.Pp
|
|
Creation of the system drive instances failed; attachment of one or more
|
|
system drives may have been aborted.
|
|
.It mlxd%d: detaching...
|
|
.Pp
|
|
The indicated system drive is being detached.
|
|
.It mlxd%d: still open, can't detach
|
|
.Pp
|
|
The indicated system drive is still open or mounted;
|
|
the controller cannot be detached.
|
|
.It mlx%d: flushing cache...
|
|
.Pp
|
|
The controller cache is being flushed prior to detach or shutdown.
|
|
.El
|
|
.Ss Operational diagnostics:
|
|
.Bl -diag
|
|
.It mlx%d: ENQUIRY failed - %s
|
|
.It mlx%d: ENQUIRY2 failed
|
|
.It mlx%d: ENQUIRY_OLD failed
|
|
.It mlx%d: FLUSH failed - %s
|
|
.It mlx%d: CHECK ASYNC failed - %s
|
|
.It mlx%d: REBUILD ASYNC failed - %s
|
|
.It mlx%d: command failed - %s
|
|
.Pp
|
|
The controller rejected a command for the reason given.
|
|
.It mlx%d: I/O beyond end of unit (%u,%d > %u)
|
|
.It mlx%d: I/O error - %s
|
|
.Pp
|
|
An I/O error was reported by the controller.
|
|
.It mlx%d: periodic enquiry failed - %s
|
|
.Pp
|
|
An attempt to poll the controller for status failed for the reason given.
|
|
.It mlx%d: mlx_periodic_enquiry: unknown command %x
|
|
.Pp
|
|
The periodic status poll has issued a command which has become corrupted.
|
|
.It mlxd%d: drive offline
|
|
.It mlxd%d: drive online
|
|
.It mlxd%d: drive critical
|
|
.Pp
|
|
The system disk indicated has changed state.
|
|
.It mlx%d: physical drive %d:%d reset
|
|
.It mlx%d: physical drive %d:%d killed %s
|
|
.It "mlx%d: physical drive %d:%d error log: sense = %d asc = %x asq = %x"
|
|
.It "mlx%d: info %4D csi %4D"
|
|
.Pp
|
|
The drive at channel:target has been reset, killed for the given reason,
|
|
or experienced a SCSI error.
|
|
.It mlx%d: unknown log message type %x
|
|
.It mlx%d: error reading message log - %s
|
|
.Pp
|
|
An error occurred while trying to read the controller's message log.
|
|
.It mlxd%d: consistency check started
|
|
.It mlx%d: consistency check completed
|
|
.Pp
|
|
A user-initiated consistency check has started/completed.
|
|
.It mlx%d: drive rebuild started for %d:%d
|
|
.It mlx%d: drive rebuild completed
|
|
.Pp
|
|
A user-initiated physical drive rebuild has started/completed.
|
|
.It mlx%d: background check/rebuild operation started
|
|
.It mlx%d: background check/rebuild operation completed
|
|
.Pp
|
|
An automatic system drive consistency check
|
|
or physical drive rebuild has started/completed.
|
|
.It mlx%d: channel %d pausing for %d seconds
|
|
.It mlx%d: channel %d resuming
|
|
.It mlx%d: pause command failed - %s
|
|
.It mlx%d: pause failed for channel %d
|
|
.It mlx%d: resume command failed - %s
|
|
.It mlx%d: resume failed for channel %d
|
|
.Pp
|
|
Controller/channel pause operation notification.
|
|
(Channel pause is not currently supported on any controller.)
|
|
.It mlx%d: controller wedged (not taking commands)
|
|
.Pp
|
|
The controller is not responding to attempts to submit new commands.
|
|
.It mlx%d: duplicate done event for slot %d
|
|
.It mlx%d: done event for nonbusy slot %d
|
|
.Pp
|
|
Corruption has occurred in either the controller's onboard list of commands
|
|
or in the driver.
|
|
.El
|
|
.Sh SEE ALSO
|
|
.Xr mlxcontrol 8
|
|
.Sh AUTHORS
|
|
.An -nosplit
|
|
The
|
|
.Nm
|
|
driver was written by
|
|
.An Michael Smith Aq Mt msmith@FreeBSD.org .
|
|
.Pp
|
|
This manual page was written by
|
|
.An Jeroen Ruigrok van der Werven Aq Mt asmodai@FreeBSD.org
|
|
and
|
|
.An Michael Smith Aq Mt msmith@FreeBSD.org .
|
|
.Sh BUGS
|
|
The driver does not yet support EISA adapters.
|
|
The DEC KZPSC has insufficient flash ROM to hold any reasonably recent firmware.
|
|
This has caused problems for this driver.
|
|
.Pp
|
|
The driver does not yet support the version 6.x firmware as found in the
|
|
AcceleRAID 352 and eXtremeRAID 2000 and 3000 products.
|