ed445694ae
8 RJ11, 8 Octacable, and 8 (used with RocketPort I/F box). Note: untested due to lack of hardware
902 lines
26 KiB
C
902 lines
26 KiB
C
/* $NetBSD: pucdata.c,v 1.25 2001/12/16 22:23:01 thorpej Exp $ */
|
|
|
|
/*
|
|
* Copyright (c) 1998, 1999 Christopher G. Demetriou. All rights reserved.
|
|
*
|
|
* Redistribution and use in source and binary forms, with or without
|
|
* modification, are permitted provided that the following conditions
|
|
* are met:
|
|
* 1. Redistributions of source code must retain the above copyright
|
|
* notice, this list of conditions and the following disclaimer.
|
|
* 2. Redistributions in binary form must reproduce the above copyright
|
|
* notice, this list of conditions and the following disclaimer in the
|
|
* documentation and/or other materials provided with the distribution.
|
|
* 3. All advertising materials mentioning features or use of this software
|
|
* must display the following acknowledgement:
|
|
* This product includes software developed by Christopher G. Demetriou
|
|
* for the NetBSD Project.
|
|
* 4. The name of the author may not be used to endorse or promote products
|
|
* derived from this software without specific prior written permission
|
|
*
|
|
* THIS SOFTWARE IS PROVIDED BY THE AUTHOR ``AS IS'' AND ANY EXPRESS OR
|
|
* IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
|
|
* OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED.
|
|
* IN NO EVENT SHALL THE AUTHOR BE LIABLE FOR ANY DIRECT, INDIRECT,
|
|
* INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT
|
|
* NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
|
|
* DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
|
|
* THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
|
* (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF
|
|
* THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
*/
|
|
|
|
#include <sys/cdefs.h>
|
|
__FBSDID("$FreeBSD$");
|
|
|
|
/*
|
|
* PCI "universal" communications card driver configuration data (used to
|
|
* match/attach the cards).
|
|
*/
|
|
|
|
#include <sys/param.h>
|
|
|
|
#include <dev/pci/pcireg.h>
|
|
#include <dev/pci/pcivar.h>
|
|
#include <dev/sio/sioreg.h>
|
|
#include <dev/puc/pucvar.h>
|
|
|
|
#define COM_FREQ DEFAULT_RCLK
|
|
|
|
const struct puc_device_description puc_devices[] = {
|
|
|
|
{ "Comtrol RocketPort 550/4 RJ45",
|
|
{ 0x11fe, 0x8014, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 4 },
|
|
},
|
|
},
|
|
|
|
{ "Comtrol RocketPort 550/Quad",
|
|
{ 0x11fe, 0x8015, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 4 },
|
|
},
|
|
},
|
|
|
|
{ "Comtrol RocketPort 550/8 RJ11 part A",
|
|
{ 0x11fe, 0x8010, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 4 },
|
|
},
|
|
},
|
|
{ "Comtrol RocketPort 550/8 RJ11 part B",
|
|
{ 0x11fe, 0x8011, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 4 },
|
|
},
|
|
},
|
|
|
|
{ "Comtrol RocketPort 550/8 Octa part A",
|
|
{ 0x11fe, 0x8012, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 4 },
|
|
},
|
|
},
|
|
{ "Comtrol RocketPort 550/8 Octa part B",
|
|
{ 0x11fe, 0x8013, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 4 },
|
|
},
|
|
},
|
|
|
|
{ "Comtrol RocketPort 550/8 part A",
|
|
{ 0x11fe, 0x8018, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 4 },
|
|
},
|
|
},
|
|
{ "Comtrol RocketPort 550/8 part B",
|
|
{ 0x11fe, 0x8019, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 4 },
|
|
},
|
|
},
|
|
|
|
{ "Comtrol RocketPort 550/16 part A",
|
|
{ 0x11fe, 0x8016, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 4 },
|
|
},
|
|
},
|
|
{ "Comtrol RocketPort 550/16 part B",
|
|
{ 0x11fe, 0x8017, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x20, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x28, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x30, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x38, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x40, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x48, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x50, COM_FREQ * 4 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x58, COM_FREQ * 4 },
|
|
},
|
|
},
|
|
|
|
/*
|
|
* XXX no entry because I have no data:
|
|
* XXX Dolphin Peripherals 4006 (single parallel)
|
|
*/
|
|
|
|
/*
|
|
* Dolphin Peripherals 4014 (dual parallel port) card. PLX 9050, with
|
|
* a seemingly-lame EEPROM setup that puts the Dolphin IDs
|
|
* into the subsystem fields, and claims that it's a
|
|
* network/misc (0x02/0x80) device.
|
|
*/
|
|
{ "Dolphin Peripherals 4014",
|
|
{ 0x10b5, 0x9050, 0xd84d, 0x6810 },
|
|
{ 0xffff, 0xffff, 0xffff, 0xffff },
|
|
{
|
|
{ PUC_PORT_TYPE_LPT, 0x20, 0x00, 0x00 },
|
|
{ PUC_PORT_TYPE_LPT, 0x24, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/*
|
|
* XXX Dolphin Peripherals 4025 (single serial)
|
|
* (clashes with Dolphin Peripherals 4036 (2s variant)
|
|
*/
|
|
|
|
/*
|
|
* Dolphin Peripherals 4035 (dual serial port) card. PLX 9050, with
|
|
* a seemingly-lame EEPROM setup that puts the Dolphin IDs
|
|
* into the subsystem fields, and claims that it's a
|
|
* network/misc (0x02/0x80) device.
|
|
*/
|
|
{ "Dolphin Peripherals 4035",
|
|
{ 0x10b5, 0x9050, 0xd84d, 0x6808 },
|
|
{ 0xffff, 0xffff, 0xffff, 0xffff },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/*
|
|
* Dolphin Peripherals 4036 (dual serial port) card.
|
|
* (Dolpin 4025 has the same ID but only one port)
|
|
*/
|
|
{ "Dolphin Peripherals 4036",
|
|
{ 0x1409, 0x7168, 0x0, 0x0 },
|
|
{ 0xffff, 0xffff, 0x0, 0x0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 8},
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 8},
|
|
},
|
|
},
|
|
|
|
/*
|
|
* XXX no entry because I have no data:
|
|
* XXX Dolphin Peripherals 4078 (dual serial and single parallel)
|
|
*/
|
|
|
|
|
|
/*
|
|
* SIIG Boards.
|
|
*
|
|
* SIIG provides documentation for their boards at:
|
|
* <URL:http://www.siig.com/driver.htm>
|
|
*
|
|
* Please excuse the weird ordering, it's the order they
|
|
* use in their documentation.
|
|
*/
|
|
|
|
/*
|
|
* SIIG "10x" family boards.
|
|
*/
|
|
|
|
/* SIIG Cyber Serial PCI 16C550 (10x family): 1S */
|
|
{ "SIIG Cyber Serial PCI 16C550 (10x family)",
|
|
{ 0x131f, 0x1000, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial PCI 16C650 (10x family): 1S */
|
|
{ "SIIG Cyber Serial PCI 16C650 (10x family)",
|
|
{ 0x131f, 0x1001, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial PCI 16C850 (10x family): 1S */
|
|
{ "SIIG Cyber Serial PCI 16C850 (10x family)",
|
|
{ 0x131f, 0x1002, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber I/O PCI 16C550 (10x family): 1S, 1P */
|
|
{ "SIIG Cyber I/O PCI 16C550 (10x family)",
|
|
{ 0x131f, 0x1010, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x1c, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber I/O PCI 16C650 (10x family): 1S, 1P */
|
|
{ "SIIG Cyber I/O PCI 16C650 (10x family)",
|
|
{ 0x131f, 0x1011, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x1c, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber I/O PCI 16C850 (10x family): 1S, 1P */
|
|
{ "SIIG Cyber I/O PCI 16C850 (10x family)",
|
|
{ 0x131f, 0x1012, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x1c, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Parallel PCI (10x family): 1P */
|
|
{ "SIIG Cyber Parallel PCI (10x family)",
|
|
{ 0x131f, 0x1020, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_LPT, 0x18, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Parallel Dual PCI (10x family): 2P */
|
|
{ "SIIG Cyber Parallel Dual PCI (10x family)",
|
|
{ 0x131f, 0x1021, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_LPT, 0x18, 0x00, 0x00 },
|
|
{ PUC_PORT_TYPE_LPT, 0x20, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial Dual PCI 16C550 (10x family): 2S */
|
|
{ "SIIG Cyber Serial Dual PCI 16C550 (10x family)",
|
|
{ 0x131f, 0x1030, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial Dual PCI 16C650 (10x family): 2S */
|
|
{ "SIIG Cyber Serial Dual PCI 16C650 (10x family)",
|
|
{ 0x131f, 0x1031, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial Dual PCI 16C850 (10x family): 2S */
|
|
{ "SIIG Cyber Serial Dual PCI 16C850 (10x family)",
|
|
{ 0x131f, 0x1032, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 2S1P PCI 16C550 (10x family): 2S, 1P */
|
|
{ "SIIG Cyber 2S1P PCI 16C550 (10x family)",
|
|
{ 0x131f, 0x1034, 0, 0 }, /* XXX really? */
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x20, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 2S1P PCI 16C650 (10x family): 2S, 1P */
|
|
{ "SIIG Cyber 2S1P PCI 16C650 (10x family)",
|
|
{ 0x131f, 0x1035, 0, 0 }, /* XXX really? */
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x20, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 2S1P PCI 16C850 (10x family): 2S, 1P */
|
|
{ "SIIG Cyber 2S1P PCI 16C850 (10x family)",
|
|
{ 0x131f, 0x1036, 0, 0 }, /* XXX really? */
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x20, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 4S PCI 16C550 (10x family): 4S */
|
|
{ "SIIG Cyber 4S PCI 16C550 (10x family)",
|
|
{ 0x131f, 0x1050, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x20, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x24, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 4S PCI 16C650 (10x family): 4S */
|
|
{ "SIIG Cyber 4S PCI 16C650 (10x family)",
|
|
{ 0x131f, 0x1051, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x20, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x24, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 4S PCI 16C850 (10x family): 4S */
|
|
{ "SIIG Cyber 4S PCI 16C850 (10x family)",
|
|
{ 0x131f, 0x1052, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x20, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x24, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/*
|
|
* SIIG "20x" family boards.
|
|
*/
|
|
|
|
/* SIIG Cyber Parallel PCI (20x family): 1P */
|
|
{ "SIIG Cyber Parallel PCI (20x family)",
|
|
{ 0x131f, 0x2020, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_LPT, 0x10, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Parallel Dual PCI (20x family): 2P */
|
|
{ "SIIG Cyber Parallel Dual PCI (20x family)",
|
|
{ 0x131f, 0x2021, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_LPT, 0x10, 0x00, 0x00 },
|
|
{ PUC_PORT_TYPE_LPT, 0x18, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 2P1S PCI 16C550 (20x family): 1S, 2P */
|
|
{ "SIIG Cyber 2P1S PCI 16C550 (20x family)",
|
|
{ 0x131f, 0x2040, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x14, 0x00, 0x00 },
|
|
{ PUC_PORT_TYPE_LPT, 0x1c, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 2P1S PCI 16C650 (20x family): 1S, 2P */
|
|
{ "SIIG Cyber 2P1S PCI 16C650 (20x family)",
|
|
{ 0x131f, 0x2041, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x14, 0x00, 0x00 },
|
|
{ PUC_PORT_TYPE_LPT, 0x1c, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 2P1S PCI 16C850 (20x family): 1S, 2P */
|
|
{ "SIIG Cyber 2P1S PCI 16C850 (20x family)",
|
|
{ 0x131f, 0x2042, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x14, 0x00, 0x00 },
|
|
{ PUC_PORT_TYPE_LPT, 0x1c, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial PCI 16C550 (20x family): 1S */
|
|
{ "SIIG Cyber Serial PCI 16C550 (20x family)",
|
|
{ 0x131f, 0x2000, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial PCI 16C650 (20x family): 1S */
|
|
{ "SIIG Cyber Serial PCI 16C650 (20x family)",
|
|
{ 0x131f, 0x2001, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial PCI 16C850 (20x family): 1S */
|
|
{ "SIIG Cyber Serial PCI 16C850 (20x family)",
|
|
{ 0x131f, 0x2002, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber I/O PCI 16C550 (20x family): 1S, 1P */
|
|
{ "SIIG Cyber I/O PCI 16C550 (20x family)",
|
|
{ 0x131f, 0x2010, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x14, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber I/O PCI 16C650 (20x family): 1S, 1P */
|
|
{ "SIIG Cyber I/O PCI 16C650 (20x family)",
|
|
{ 0x131f, 0x2011, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x14, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber I/O PCI 16C850 (20x family): 1S, 1P */
|
|
{ "SIIG Cyber I/O PCI 16C850 (20x family)",
|
|
{ 0x131f, 0x2012, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x14, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial Dual PCI 16C550 (20x family): 2S */
|
|
{ "SIIG Cyber Serial Dual PCI 16C550 (20x family)",
|
|
{ 0x131f, 0x2030, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial Dual PCI 16C650 (20x family): 2S */
|
|
{ "SIIG Cyber Serial Dual PCI 16C650 (20x family)",
|
|
{ 0x131f, 0x2031, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber Serial Dual PCI 16C850 (20x family): 2S */
|
|
{ "SIIG Cyber Serial Dual PCI 16C850 (20x family)",
|
|
{ 0x131f, 0x2032, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 2S1P PCI 16C550 (20x family): 2S, 1P */
|
|
{ "SIIG Cyber 2S1P PCI 16C550 (20x family)",
|
|
{ 0x131f, 0x2060, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x18, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 2S1P PCI 16C650 (20x family): 2S, 1P */
|
|
{ "SIIG Cyber 2S1P PCI 16C650 (20x family)",
|
|
{ 0x131f, 0x2061, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x18, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 2S1P PCI 16C850 (20x family): 2S, 1P */
|
|
{ "SIIG Cyber 2S1P PCI 16C850 (20x family)",
|
|
{ 0x131f, 0x2062, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x18, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 4S PCI 16C550 (20x family): 4S */
|
|
{ "SIIG Cyber 4S PCI 16C550 (20x family)",
|
|
{ 0x131f, 0x2050, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 4S PCI 16C650 (20x family): 4S */
|
|
{ "SIIG Cyber 4S PCI 16C650 (20x family)",
|
|
{ 0x131f, 0x2051, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SIIG Cyber 4S PCI 16C850 (20x family): 4S */
|
|
{ "SIIG Cyber 4S PCI 16C850 (20x family)",
|
|
{ 0x131f, 0x2052, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* VScom PCI-400: 4S */
|
|
{ "VScom PCI-400",
|
|
{ 0x10b5, 0x1077, 0x10b5, 0x1077 },
|
|
{ 0xffff, 0xffff, 0xffff, 0xffff },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x08, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x10, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x18, COM_FREQ * 8 },
|
|
},
|
|
},
|
|
|
|
/* VScom PCI-800: 8S */
|
|
{ "VScom PCI-800",
|
|
{ 0x10b5, 0x1076, 0x10b5, 0x1076 },
|
|
{ 0xffff, 0xffff, 0xffff, 0xffff },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x08, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x10, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x18, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x20, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x28, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x30, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x38, COM_FREQ * 8 },
|
|
},
|
|
},
|
|
/*
|
|
* VScom PCI-800H. Uses 8 16950 UART, behind a PCI chips that offers
|
|
* 4 com port on PCI device 0 and 4 on PCI device 1. PCI device 0 has
|
|
* device ID 3 and PCI device 1 device ID 4.
|
|
*/
|
|
{ "Titan PCI-800H",
|
|
{ 0x14d2, 0xa003, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 8 },
|
|
},
|
|
},
|
|
{ "Titan PCI-800H",
|
|
{ 0x14d2, 0xa004, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ * 8 },
|
|
},
|
|
},
|
|
{ "Titan PCI-200H",
|
|
{ 0x14d2, 0xa005, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ * 8 },
|
|
},
|
|
},
|
|
|
|
/* NEC PK-UG-X001 K56flex PCI Modem card.
|
|
NEC MARTH bridge chip and Rockwell RCVDL56ACF/SP using. */
|
|
{ "NEC PK-UG-X001 K56flex PCI Modem",
|
|
{ 0x1033, 0x0074, 0x1033, 0x8014 },
|
|
{ 0xffff, 0xffff, 0xffff, 0xffff },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* NEC PK-UG-X008 */
|
|
{ "NEC PK-UG-X008",
|
|
{ 0x1033, 0x007d, 0x1033, 0x8012 },
|
|
{ 0xffff, 0xffff, 0xffff, 0xffff },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ},
|
|
},
|
|
},
|
|
|
|
/* Lava Computers 2SP-PCI */
|
|
{ "Lava Computers 2SP-PCI parallel port",
|
|
{ 0x1407, 0x8000, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_LPT, 0x10, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* Lava Computers 2SP-PCI and Quattro-PCI serial ports */
|
|
{ "Lava Computers dual serial port",
|
|
{ 0x1407, 0x0100, 0, 0 },
|
|
{ 0xffff, 0xfffc, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* Lava Computers newer Quattro-PCI serial ports */
|
|
{ "Lava Computers Quattro-PCI serial port",
|
|
{ 0x1407, 0x0120, 0, 0 },
|
|
{ 0xffff, 0xfffc, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* Lava Computers DSerial PCI serial ports */
|
|
{ "Lava Computers serial port",
|
|
{ 0x1407, 0x0110, 0, 0 },
|
|
{ 0xffff, 0xfffc, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* Lava Computers Octopus-550 serial ports */
|
|
{ "Lava Computers Octopus-550 8-port serial",
|
|
{ 0x1407, 0x0180, 0, 0 },
|
|
{ 0xffff, 0xfffc, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* US Robotics (3Com) PCI Modems */
|
|
{ "US Robotics (3Com) 3CP5609 PCI 16550 Modem",
|
|
{ 0x12b9, 0x1008, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* Actiontec 56K PCI Master */
|
|
{ "Actiontec 56K PCI Master",
|
|
{ 0x11c1, 0x0480, 0x0, 0x0 },
|
|
{ 0xffff, 0xffff, 0x0, 0x0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/*
|
|
* Boards with an Oxford Semiconductor chip.
|
|
*
|
|
* Oxford Semiconductor provides documentation for their chip at:
|
|
* <URL:http://www.oxsemi.com/products/uarts/index.html>
|
|
*
|
|
* As sold by Kouwell <URL:http://www.kouwell.com/>.
|
|
* I/O Flex PCI I/O Card Model-223 with 4 serial and 1 parallel ports.
|
|
*/
|
|
|
|
/* Oxford Semiconductor OX16PCI954 PCI UARTs */
|
|
{ "Qxford Semiconductor OX16PCI954 UARTs",
|
|
{ 0x1415, 0x9501, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x08, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x10, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x18, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* Oxford Semiconductor OX16PCI954 PCI Parallel port */
|
|
{ "Qxford Semiconductor OX16PCI954 Parallel port",
|
|
{ 0x1415, 0x9513, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_LPT, 0x10, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* NetMos 2S1P PCI 16C650 : 2S, 1P */
|
|
{ "NetMos NM9835 Dual UART and 1284 Printer port",
|
|
{ 0x9710, 0x9835, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x18, 0x00, 0x00 },
|
|
},
|
|
},
|
|
|
|
/*
|
|
* This is the Middle Digital, Inc. PCI-Weasel, which
|
|
* uses a PCI interface implemented in FPGA.
|
|
*/
|
|
{ "Middle Digital, Inc. Weasel serial port",
|
|
{ 0xdeaf, 0x9051, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* SD-LAB PCI I/O Card 4S2P */
|
|
{ "Syba Tech Ltd. PCI-4S2P-550-ECP",
|
|
{ 0x1592, 0x0781, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x2e8, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x2f8, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x10, 0x000, 0x00 },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x3e8, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x3f8, COM_FREQ },
|
|
{ PUC_PORT_TYPE_LPT, 0x10, 0x000, 0x00 },
|
|
},
|
|
},
|
|
|
|
/* Moxa Technologies Co., Ltd. PCI I/O Card 4S RS232/422/485 */
|
|
{ "Moxa Technologies, Industio CP-114",
|
|
{ 0x1393, 0x1141, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0, },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x08, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x10, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x18, COM_FREQ * 8 },
|
|
},
|
|
},
|
|
|
|
/* Moxa Technologies Co., Ltd. PCI I/O Card 8S RS232 */
|
|
{ "Moxa Technologies, C168H/PCI",
|
|
{ 0x1393, 0x1680, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0, },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x00, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x08, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x10, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x18, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x20, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x28, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x30, COM_FREQ * 8 },
|
|
{ PUC_PORT_TYPE_COM, 0x18, 0x38, COM_FREQ * 8 },
|
|
},
|
|
},
|
|
|
|
{ "Avlab Technology, PCI IO 2S",
|
|
{ 0x14db, 0x2130, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x10, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x14, 0x00, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
/* Decision Computer Inc, serial ports */
|
|
{ "Decision Computer Inc, PCCOM 4-port serial",
|
|
{ 0x6666, 0x0001, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x08, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x10, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x18, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
{ "PCCOM dual port RS232/422/485",
|
|
{ 0x6666, 0x0004, 0, 0 },
|
|
{ 0xffff, 0xffff, 0, 0 },
|
|
{
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x00, COM_FREQ },
|
|
{ PUC_PORT_TYPE_COM, 0x1c, 0x08, COM_FREQ },
|
|
},
|
|
},
|
|
|
|
{ 0 }
|
|
};
|