net/enic: restore default log level to info
Prior to the fix, RTE_LOGTYPE_INFO messages were displayed by default. After the fix, only NOTICE level and higher were displayed by default and INFO level were not. There are INFO level vNIC config related messages which customers and tech support currently depend on for debugging and so on and to suddenly hide these messages is not a good idea. This patch changes the default log level to RTE_LOG_INFO for enic so messages are printed as before the fix. Fixes: bbd8ecc05434 ("net/enic: remove PMD log type references") Signed-off-by: John Daley <johndale@cisco.com>
This commit is contained in:
parent
e0e5d23b3c
commit
1480787d08
@ -73,7 +73,7 @@ RTE_INIT(enicpmd_init_log)
|
||||
{
|
||||
enic_pmd_logtype = rte_log_register("pmd.net.enic");
|
||||
if (enic_pmd_logtype >= 0)
|
||||
rte_log_set_level(enic_pmd_logtype, RTE_LOG_NOTICE);
|
||||
rte_log_set_level(enic_pmd_logtype, RTE_LOG_INFO);
|
||||
}
|
||||
|
||||
static int
|
||||
|
Loading…
x
Reference in New Issue
Block a user