doc: add i40e guide
A new doc is added to introduce i40e pmd driver. Signed-off-by: Jingjing Wu <jingjing.wu@intel.com> Acked-by: John McNamara <john.mcnamara@intel.com>
This commit is contained in:
parent
173cd7910f
commit
21fefd1c71
368
doc/guides/nics/i40e.rst
Normal file
368
doc/guides/nics/i40e.rst
Normal file
@ -0,0 +1,368 @@
|
||||
.. BSD LICENSE
|
||||
Copyright(c) 2016 Intel Corporation. All rights reserved.
|
||||
All rights reserved.
|
||||
|
||||
Redistribution and use in source and binary forms, with or without
|
||||
modification, are permitted provided that the following conditions
|
||||
are met:
|
||||
|
||||
* Redistributions of source code must retain the above copyright
|
||||
notice, this list of conditions and the following disclaimer.
|
||||
* Redistributions in binary form must reproduce the above copyright
|
||||
notice, this list of conditions and the following disclaimer in
|
||||
the documentation and/or other materials provided with the
|
||||
distribution.
|
||||
* Neither the name of Intel Corporation nor the names of its
|
||||
contributors may be used to endorse or promote products derived
|
||||
from this software without specific prior written permission.
|
||||
|
||||
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
|
||||
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
|
||||
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
|
||||
A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
|
||||
OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
|
||||
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
|
||||
LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
|
||||
DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
|
||||
THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
||||
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
|
||||
OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
||||
|
||||
I40E Poll Mode Driver
|
||||
======================
|
||||
|
||||
The I40E PMD (librte_pmd_i40e) provides poll mode driver support
|
||||
for the Intel X710/XL710/X722 10/40 Gbps family of adapters.
|
||||
|
||||
|
||||
Features
|
||||
--------
|
||||
|
||||
Features of the I40E PMD are:
|
||||
|
||||
- Multiple queues for TX and RX
|
||||
- Receiver Side Scaling (RSS)
|
||||
- MAC/VLAN filtering
|
||||
- Packet type information
|
||||
- Flow director
|
||||
- Cloud filter
|
||||
- Checksum offload
|
||||
- VLAN/QinQ stripping and inserting
|
||||
- TSO offload
|
||||
- Promiscuous mode
|
||||
- Multicast mode
|
||||
- Port hardware statistics
|
||||
- Jumbo frames
|
||||
- Link state information
|
||||
- Link flow control
|
||||
- Mirror on port, VLAN and VSI
|
||||
- Interrupt mode for RX
|
||||
- Scattered and gather for TX and RX
|
||||
- Vector Poll mode driver
|
||||
- DCB
|
||||
- VMDQ
|
||||
- SR-IOV VF
|
||||
- Hot plug
|
||||
- IEEE1588/802.1AS timestamping
|
||||
|
||||
|
||||
Prerequisites
|
||||
-------------
|
||||
|
||||
- Identifying your adapter using `Intel Support
|
||||
<http://www.intel.com/support>`_ and get the latest NVM/FW images.
|
||||
|
||||
- Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
|
||||
|
||||
- To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
|
||||
section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
|
||||
|
||||
|
||||
Pre-Installation Configuration
|
||||
------------------------------
|
||||
|
||||
Config File Options
|
||||
~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The following options can be modified in the ``config`` file.
|
||||
Please note that enabling debugging options may affect system performance.
|
||||
|
||||
- ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
|
||||
|
||||
Toggle compilation of the ``librte_pmd_i40e`` driver.
|
||||
|
||||
- ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
|
||||
|
||||
Toggle display of generic debugging messages.
|
||||
|
||||
- ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
|
||||
|
||||
Toggle bulk allocation for RX.
|
||||
|
||||
- ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
|
||||
|
||||
Toggle the use of Vector PMD instead of normal RX/TX path.
|
||||
To enable vPMD for RX, bulk allocation for Rx must be allowed.
|
||||
|
||||
- ``CONFIG_RTE_LIBRTE_I40E_RX_OLFLAGS_ENABLE`` (default ``y``)
|
||||
|
||||
Toggle to enable RX ``olflags``.
|
||||
This is only meaningful when Vector PMD is used.
|
||||
|
||||
- ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
|
||||
|
||||
Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
|
||||
|
||||
- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
|
||||
|
||||
Number of queues reserved for PF.
|
||||
|
||||
- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VF`` (default ``4``)
|
||||
|
||||
Number of queues reserved for each SR-IOV VF.
|
||||
|
||||
- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
|
||||
|
||||
Number of queues reserved for each VMDQ Pool.
|
||||
|
||||
- ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` (default ``-1``)
|
||||
|
||||
Interrupt Throttling interval.
|
||||
|
||||
|
||||
Driver Compilation
|
||||
~~~~~~~~~~~~~~~~~~
|
||||
|
||||
To compile the I40E PMD see :ref:`Getting Started Guide for Linux <linux_gsg>` or
|
||||
:ref:`Getting Started Guide for FreeBSD <freebsd_gsg>` depending on your platform.
|
||||
|
||||
|
||||
Linux
|
||||
-----
|
||||
|
||||
|
||||
Running testpmd
|
||||
~~~~~~~~~~~~~~~
|
||||
|
||||
This section demonstrates how to launch ``testpmd`` with Intel XL710/X710
|
||||
devices managed by ``librte_pmd_i40e`` in the Linux operating system.
|
||||
|
||||
#. Load ``igb_uio`` or ``vfio-pci`` driver:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
modprobe uio
|
||||
insmod ./x86_64-native-linuxapp-gcc/kmod/igb_uio.ko
|
||||
|
||||
or
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
modprobe vfio-pci
|
||||
|
||||
#. Bind the XL710/X710 adapters to ``igb_uio`` or ``vfio-pci`` loaded in the previous step:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
./tools/dpdk_nic_bind.py --bind igb_uio 0000:83:00.0
|
||||
|
||||
Or setup VFIO permissions for regular users and then bind to ``vfio-pci``:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
./tools/dpdk_nic_bind.py --bind vfio-pci 0000:83:00.0
|
||||
|
||||
#. Start ``testpmd`` with basic parameters:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
./x86_64-native-linuxapp-gcc/app/testpmd -c 0xf -n 4 -w 83:00.0 -- -i
|
||||
|
||||
Example output:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
...
|
||||
EAL: PCI device 0000:83:00.0 on NUMA socket 1
|
||||
EAL: probe driver: 8086:1572 rte_i40e_pmd
|
||||
EAL: PCI memory mapped at 0x7f7f80000000
|
||||
EAL: PCI memory mapped at 0x7f7f80800000
|
||||
PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
|
||||
Interactive-mode selected
|
||||
Configuring Port 0 (socket 0)
|
||||
...
|
||||
|
||||
PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
|
||||
satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
|
||||
|
||||
...
|
||||
Port 0: 68:05:CA:26:85:84
|
||||
Checking link statuses...
|
||||
Port 0 Link Up - speed 10000 Mbps - full-duplex
|
||||
Done
|
||||
|
||||
testpmd>
|
||||
|
||||
|
||||
SR-IOV: Prerequisites and sample Application Notes
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
#. Load the kernel module:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
modprobe i40e
|
||||
|
||||
Check the output in dmesg:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
i40e 0000:83:00.1 ens802f0: renamed from eth0
|
||||
|
||||
#. Bring up the PF ports:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
ifconfig ens802f0 up
|
||||
|
||||
#. Create VF device(s):
|
||||
|
||||
Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
|
||||
of the parent PF.
|
||||
|
||||
Example:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
|
||||
|
||||
|
||||
#. Assign VF MAC address:
|
||||
|
||||
Assign MAC address to the VF using iproute2 utility. The syntax is:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
ip link set <PF netdev id> vf <VF id> mac <macaddr>
|
||||
|
||||
Example:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
|
||||
|
||||
#. Assign VF to VM, and bring up the VM.
|
||||
Please see the documenation for the*I40E/IXGBE/IGB Virtual Function Driver*.
|
||||
|
||||
|
||||
Sample Application Notes
|
||||
------------------------
|
||||
|
||||
Vlan filter
|
||||
~~~~~~~~~~~
|
||||
|
||||
Vlan filter only works when Promiscuous mode is off.
|
||||
|
||||
To start ``testpmd``, and add vlan 10 to port 0:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
./app/testpmd -c ffff -n 4 -- -i --forward-mode=mac
|
||||
...
|
||||
|
||||
testpmd> set promisc 0 off
|
||||
testpmd> rx_vlan add 10 0
|
||||
|
||||
|
||||
Flow Director
|
||||
~~~~~~~~~~~~~
|
||||
|
||||
The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
|
||||
The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
|
||||
|
||||
The default input set of each flow type is::
|
||||
|
||||
ipv4-other : src_ip_address, dst_ip_address
|
||||
ipv4-frag : src_ip_address, dst_ip_address
|
||||
ipv4-tcp : src_ip_address, dst_ip_address, src_port, dst_port
|
||||
ipv4-udp : src_ip_address, dst_ip_address, src_port, dst_port
|
||||
ipv4-sctp : src_ip_address, dst_ip_address, src_port, dst_port,
|
||||
verification_tag
|
||||
ipv6-other : src_ip_address, dst_ip_address
|
||||
ipv6-frag : src_ip_address, dst_ip_address
|
||||
ipv6-tcp : src_ip_address, dst_ip_address, src_port, dst_port
|
||||
ipv6-udp : src_ip_address, dst_ip_address, src_port, dst_port
|
||||
ipv6-sctp : src_ip_address, dst_ip_address, src_port, dst_port,
|
||||
verification_tag
|
||||
l2_payload : ether_type
|
||||
|
||||
The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
|
||||
|
||||
Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
./app/testpmd -c ffff -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
|
||||
--rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
|
||||
|
||||
Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
testpmd> flow_director_filter 0 mode IP add flow ipv4-udp \
|
||||
src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
|
||||
fwd pf queue 1 fd_id 1
|
||||
|
||||
Check the flow director status:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
testpmd> show port fdir 0
|
||||
|
||||
######################## FDIR infos for port 0 ####################
|
||||
MODE: PERFECT
|
||||
SUPPORTED FLOW TYPE: ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
|
||||
ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
|
||||
l2_payload
|
||||
FLEX PAYLOAD INFO:
|
||||
max_len: 16 payload_limit: 480
|
||||
payload_unit: 2 payload_seg: 3
|
||||
bitmask_unit: 2 bitmask_num: 2
|
||||
MASK:
|
||||
vlan_tci: 0x0000,
|
||||
src_ipv4: 0x00000000,
|
||||
dst_ipv4: 0x00000000,
|
||||
src_port: 0x0000,
|
||||
dst_port: 0x0000
|
||||
src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
|
||||
dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
|
||||
FLEX PAYLOAD SRC OFFSET:
|
||||
L2_PAYLOAD: 0 1 2 3 4 5 6 ...
|
||||
L3_PAYLOAD: 0 1 2 3 4 5 6 ...
|
||||
L4_PAYLOAD: 0 1 2 3 4 5 6 ...
|
||||
FLEX MASK CFG:
|
||||
ipv4-udp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
ipv4-tcp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
ipv4-sctp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
ipv4-other: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
ipv4-frag: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
ipv6-udp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
ipv6-tcp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
ipv6-sctp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
ipv6-other: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
ipv6-frag: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
l2_payload: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||
guarant_count: 1 best_count: 0
|
||||
guarant_space: 512 best_space: 7168
|
||||
collision: 0 free: 0
|
||||
maxhash: 0 maxlen: 0
|
||||
add: 0 remove: 0
|
||||
f_add: 0 f_remove: 0
|
||||
|
||||
|
||||
Delete all flow director rules on a port:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
testpmd> flush_flow_director 0
|
||||
|
@ -41,6 +41,7 @@ Network Interface Controller Drivers
|
||||
e1000em
|
||||
enic
|
||||
fm10k
|
||||
i40e
|
||||
ixgbe
|
||||
intel_vf
|
||||
mlx4
|
||||
|
@ -86,61 +86,61 @@ Most of these differences are summarized below.
|
||||
e e e e e e
|
||||
c c c c c c
|
||||
==================== = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
|
||||
link status
|
||||
link status event
|
||||
Rx interrupt
|
||||
queue start/stop
|
||||
link status X X
|
||||
link status event X X
|
||||
Rx interrupt X X X X
|
||||
queue start/stop X X X X
|
||||
MTU update
|
||||
jumbo frame
|
||||
scattered Rx
|
||||
jumbo frame X X X X
|
||||
scattered Rx X X X X
|
||||
LRO
|
||||
TSO
|
||||
promiscuous mode
|
||||
allmulticast mode
|
||||
unicast MAC filter
|
||||
multicast MAC filter
|
||||
RSS hash
|
||||
RSS key update
|
||||
RSS reta update
|
||||
VMDq
|
||||
SR-IOV
|
||||
DCB
|
||||
VLAN filter
|
||||
ethertype filter
|
||||
TSO X X X X
|
||||
promiscuous mode X X X X
|
||||
allmulticast mode X X X X
|
||||
unicast MAC filter X X X X
|
||||
multicast MAC filter X X X X
|
||||
RSS hash X X X X
|
||||
RSS key update X X X X
|
||||
RSS reta update X X X X
|
||||
VMDq X X
|
||||
SR-IOV X X
|
||||
DCB X X
|
||||
VLAN filter X X X X
|
||||
ethertype filter X X
|
||||
n-tuple filter
|
||||
SYN filter
|
||||
tunnel filter
|
||||
tunnel filter X X
|
||||
flexible filter
|
||||
hash filter
|
||||
flow director
|
||||
flow control
|
||||
hash filter X X X X
|
||||
flow director X X
|
||||
flow control X X
|
||||
rate limitation
|
||||
traffic mirroring
|
||||
CRC offload
|
||||
VLAN offload
|
||||
QinQ offload
|
||||
L3 checksum offload
|
||||
L4 checksum offload
|
||||
inner L3 checksum
|
||||
inner L4 checksum
|
||||
packet type parsing
|
||||
timesync
|
||||
basic stats
|
||||
extended stats
|
||||
traffic mirroring X X
|
||||
CRC offload X X
|
||||
VLAN offload X X
|
||||
QinQ offload X X
|
||||
L3 checksum offload X X
|
||||
L4 checksum offload X X
|
||||
inner L3 checksum X X
|
||||
inner L4 checksum X X
|
||||
packet type parsing X X
|
||||
timesync X X
|
||||
basic stats X X X X
|
||||
extended stats X X X X
|
||||
stats per queue
|
||||
EEPROM dump
|
||||
registers dump
|
||||
multiprocess aware
|
||||
BSD nic_uio
|
||||
Linux UIO
|
||||
Linux VFIO
|
||||
multiprocess aware X X X X
|
||||
BSD nic_uio X X X X
|
||||
Linux UIO X X X X
|
||||
Linux VFIO X X X X
|
||||
other kdrv
|
||||
ARMv7
|
||||
ARMv8
|
||||
Power8
|
||||
TILE-Gx
|
||||
x86-32
|
||||
x86-64
|
||||
x86-32 X X X X
|
||||
x86-64 X X X X
|
||||
usage doc
|
||||
design doc
|
||||
perf doc
|
||||
|
Loading…
Reference in New Issue