doc: add i40e guide
A new doc is added to introduce i40e pmd driver. Signed-off-by: Jingjing Wu <jingjing.wu@intel.com> Acked-by: John McNamara <john.mcnamara@intel.com>
This commit is contained in:
parent
173cd7910f
commit
21fefd1c71
368
doc/guides/nics/i40e.rst
Normal file
368
doc/guides/nics/i40e.rst
Normal file
@ -0,0 +1,368 @@
|
|||||||
|
.. BSD LICENSE
|
||||||
|
Copyright(c) 2016 Intel Corporation. All rights reserved.
|
||||||
|
All rights reserved.
|
||||||
|
|
||||||
|
Redistribution and use in source and binary forms, with or without
|
||||||
|
modification, are permitted provided that the following conditions
|
||||||
|
are met:
|
||||||
|
|
||||||
|
* Redistributions of source code must retain the above copyright
|
||||||
|
notice, this list of conditions and the following disclaimer.
|
||||||
|
* Redistributions in binary form must reproduce the above copyright
|
||||||
|
notice, this list of conditions and the following disclaimer in
|
||||||
|
the documentation and/or other materials provided with the
|
||||||
|
distribution.
|
||||||
|
* Neither the name of Intel Corporation nor the names of its
|
||||||
|
contributors may be used to endorse or promote products derived
|
||||||
|
from this software without specific prior written permission.
|
||||||
|
|
||||||
|
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
|
||||||
|
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
|
||||||
|
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
|
||||||
|
A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
|
||||||
|
OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
|
||||||
|
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
|
||||||
|
LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
|
||||||
|
DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
|
||||||
|
THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
||||||
|
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
|
||||||
|
OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
||||||
|
|
||||||
|
I40E Poll Mode Driver
|
||||||
|
======================
|
||||||
|
|
||||||
|
The I40E PMD (librte_pmd_i40e) provides poll mode driver support
|
||||||
|
for the Intel X710/XL710/X722 10/40 Gbps family of adapters.
|
||||||
|
|
||||||
|
|
||||||
|
Features
|
||||||
|
--------
|
||||||
|
|
||||||
|
Features of the I40E PMD are:
|
||||||
|
|
||||||
|
- Multiple queues for TX and RX
|
||||||
|
- Receiver Side Scaling (RSS)
|
||||||
|
- MAC/VLAN filtering
|
||||||
|
- Packet type information
|
||||||
|
- Flow director
|
||||||
|
- Cloud filter
|
||||||
|
- Checksum offload
|
||||||
|
- VLAN/QinQ stripping and inserting
|
||||||
|
- TSO offload
|
||||||
|
- Promiscuous mode
|
||||||
|
- Multicast mode
|
||||||
|
- Port hardware statistics
|
||||||
|
- Jumbo frames
|
||||||
|
- Link state information
|
||||||
|
- Link flow control
|
||||||
|
- Mirror on port, VLAN and VSI
|
||||||
|
- Interrupt mode for RX
|
||||||
|
- Scattered and gather for TX and RX
|
||||||
|
- Vector Poll mode driver
|
||||||
|
- DCB
|
||||||
|
- VMDQ
|
||||||
|
- SR-IOV VF
|
||||||
|
- Hot plug
|
||||||
|
- IEEE1588/802.1AS timestamping
|
||||||
|
|
||||||
|
|
||||||
|
Prerequisites
|
||||||
|
-------------
|
||||||
|
|
||||||
|
- Identifying your adapter using `Intel Support
|
||||||
|
<http://www.intel.com/support>`_ and get the latest NVM/FW images.
|
||||||
|
|
||||||
|
- Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
|
||||||
|
|
||||||
|
- To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
|
||||||
|
section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
|
||||||
|
|
||||||
|
|
||||||
|
Pre-Installation Configuration
|
||||||
|
------------------------------
|
||||||
|
|
||||||
|
Config File Options
|
||||||
|
~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
The following options can be modified in the ``config`` file.
|
||||||
|
Please note that enabling debugging options may affect system performance.
|
||||||
|
|
||||||
|
- ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
|
||||||
|
|
||||||
|
Toggle compilation of the ``librte_pmd_i40e`` driver.
|
||||||
|
|
||||||
|
- ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
|
||||||
|
|
||||||
|
Toggle display of generic debugging messages.
|
||||||
|
|
||||||
|
- ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
|
||||||
|
|
||||||
|
Toggle bulk allocation for RX.
|
||||||
|
|
||||||
|
- ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
|
||||||
|
|
||||||
|
Toggle the use of Vector PMD instead of normal RX/TX path.
|
||||||
|
To enable vPMD for RX, bulk allocation for Rx must be allowed.
|
||||||
|
|
||||||
|
- ``CONFIG_RTE_LIBRTE_I40E_RX_OLFLAGS_ENABLE`` (default ``y``)
|
||||||
|
|
||||||
|
Toggle to enable RX ``olflags``.
|
||||||
|
This is only meaningful when Vector PMD is used.
|
||||||
|
|
||||||
|
- ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
|
||||||
|
|
||||||
|
Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
|
||||||
|
|
||||||
|
- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
|
||||||
|
|
||||||
|
Number of queues reserved for PF.
|
||||||
|
|
||||||
|
- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VF`` (default ``4``)
|
||||||
|
|
||||||
|
Number of queues reserved for each SR-IOV VF.
|
||||||
|
|
||||||
|
- ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
|
||||||
|
|
||||||
|
Number of queues reserved for each VMDQ Pool.
|
||||||
|
|
||||||
|
- ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` (default ``-1``)
|
||||||
|
|
||||||
|
Interrupt Throttling interval.
|
||||||
|
|
||||||
|
|
||||||
|
Driver Compilation
|
||||||
|
~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
To compile the I40E PMD see :ref:`Getting Started Guide for Linux <linux_gsg>` or
|
||||||
|
:ref:`Getting Started Guide for FreeBSD <freebsd_gsg>` depending on your platform.
|
||||||
|
|
||||||
|
|
||||||
|
Linux
|
||||||
|
-----
|
||||||
|
|
||||||
|
|
||||||
|
Running testpmd
|
||||||
|
~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
This section demonstrates how to launch ``testpmd`` with Intel XL710/X710
|
||||||
|
devices managed by ``librte_pmd_i40e`` in the Linux operating system.
|
||||||
|
|
||||||
|
#. Load ``igb_uio`` or ``vfio-pci`` driver:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
modprobe uio
|
||||||
|
insmod ./x86_64-native-linuxapp-gcc/kmod/igb_uio.ko
|
||||||
|
|
||||||
|
or
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
modprobe vfio-pci
|
||||||
|
|
||||||
|
#. Bind the XL710/X710 adapters to ``igb_uio`` or ``vfio-pci`` loaded in the previous step:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
./tools/dpdk_nic_bind.py --bind igb_uio 0000:83:00.0
|
||||||
|
|
||||||
|
Or setup VFIO permissions for regular users and then bind to ``vfio-pci``:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
./tools/dpdk_nic_bind.py --bind vfio-pci 0000:83:00.0
|
||||||
|
|
||||||
|
#. Start ``testpmd`` with basic parameters:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
./x86_64-native-linuxapp-gcc/app/testpmd -c 0xf -n 4 -w 83:00.0 -- -i
|
||||||
|
|
||||||
|
Example output:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
...
|
||||||
|
EAL: PCI device 0000:83:00.0 on NUMA socket 1
|
||||||
|
EAL: probe driver: 8086:1572 rte_i40e_pmd
|
||||||
|
EAL: PCI memory mapped at 0x7f7f80000000
|
||||||
|
EAL: PCI memory mapped at 0x7f7f80800000
|
||||||
|
PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
|
||||||
|
Interactive-mode selected
|
||||||
|
Configuring Port 0 (socket 0)
|
||||||
|
...
|
||||||
|
|
||||||
|
PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
|
||||||
|
satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
|
||||||
|
|
||||||
|
...
|
||||||
|
Port 0: 68:05:CA:26:85:84
|
||||||
|
Checking link statuses...
|
||||||
|
Port 0 Link Up - speed 10000 Mbps - full-duplex
|
||||||
|
Done
|
||||||
|
|
||||||
|
testpmd>
|
||||||
|
|
||||||
|
|
||||||
|
SR-IOV: Prerequisites and sample Application Notes
|
||||||
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
#. Load the kernel module:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
modprobe i40e
|
||||||
|
|
||||||
|
Check the output in dmesg:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
i40e 0000:83:00.1 ens802f0: renamed from eth0
|
||||||
|
|
||||||
|
#. Bring up the PF ports:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
ifconfig ens802f0 up
|
||||||
|
|
||||||
|
#. Create VF device(s):
|
||||||
|
|
||||||
|
Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
|
||||||
|
of the parent PF.
|
||||||
|
|
||||||
|
Example:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
|
||||||
|
|
||||||
|
|
||||||
|
#. Assign VF MAC address:
|
||||||
|
|
||||||
|
Assign MAC address to the VF using iproute2 utility. The syntax is:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
ip link set <PF netdev id> vf <VF id> mac <macaddr>
|
||||||
|
|
||||||
|
Example:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
|
||||||
|
|
||||||
|
#. Assign VF to VM, and bring up the VM.
|
||||||
|
Please see the documenation for the*I40E/IXGBE/IGB Virtual Function Driver*.
|
||||||
|
|
||||||
|
|
||||||
|
Sample Application Notes
|
||||||
|
------------------------
|
||||||
|
|
||||||
|
Vlan filter
|
||||||
|
~~~~~~~~~~~
|
||||||
|
|
||||||
|
Vlan filter only works when Promiscuous mode is off.
|
||||||
|
|
||||||
|
To start ``testpmd``, and add vlan 10 to port 0:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
./app/testpmd -c ffff -n 4 -- -i --forward-mode=mac
|
||||||
|
...
|
||||||
|
|
||||||
|
testpmd> set promisc 0 off
|
||||||
|
testpmd> rx_vlan add 10 0
|
||||||
|
|
||||||
|
|
||||||
|
Flow Director
|
||||||
|
~~~~~~~~~~~~~
|
||||||
|
|
||||||
|
The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
|
||||||
|
The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
|
||||||
|
|
||||||
|
The default input set of each flow type is::
|
||||||
|
|
||||||
|
ipv4-other : src_ip_address, dst_ip_address
|
||||||
|
ipv4-frag : src_ip_address, dst_ip_address
|
||||||
|
ipv4-tcp : src_ip_address, dst_ip_address, src_port, dst_port
|
||||||
|
ipv4-udp : src_ip_address, dst_ip_address, src_port, dst_port
|
||||||
|
ipv4-sctp : src_ip_address, dst_ip_address, src_port, dst_port,
|
||||||
|
verification_tag
|
||||||
|
ipv6-other : src_ip_address, dst_ip_address
|
||||||
|
ipv6-frag : src_ip_address, dst_ip_address
|
||||||
|
ipv6-tcp : src_ip_address, dst_ip_address, src_port, dst_port
|
||||||
|
ipv6-udp : src_ip_address, dst_ip_address, src_port, dst_port
|
||||||
|
ipv6-sctp : src_ip_address, dst_ip_address, src_port, dst_port,
|
||||||
|
verification_tag
|
||||||
|
l2_payload : ether_type
|
||||||
|
|
||||||
|
The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
|
||||||
|
|
||||||
|
Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
./app/testpmd -c ffff -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
|
||||||
|
--rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
|
||||||
|
|
||||||
|
Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
testpmd> flow_director_filter 0 mode IP add flow ipv4-udp \
|
||||||
|
src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
|
||||||
|
fwd pf queue 1 fd_id 1
|
||||||
|
|
||||||
|
Check the flow director status:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
testpmd> show port fdir 0
|
||||||
|
|
||||||
|
######################## FDIR infos for port 0 ####################
|
||||||
|
MODE: PERFECT
|
||||||
|
SUPPORTED FLOW TYPE: ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
|
||||||
|
ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
|
||||||
|
l2_payload
|
||||||
|
FLEX PAYLOAD INFO:
|
||||||
|
max_len: 16 payload_limit: 480
|
||||||
|
payload_unit: 2 payload_seg: 3
|
||||||
|
bitmask_unit: 2 bitmask_num: 2
|
||||||
|
MASK:
|
||||||
|
vlan_tci: 0x0000,
|
||||||
|
src_ipv4: 0x00000000,
|
||||||
|
dst_ipv4: 0x00000000,
|
||||||
|
src_port: 0x0000,
|
||||||
|
dst_port: 0x0000
|
||||||
|
src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
|
||||||
|
dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
|
||||||
|
FLEX PAYLOAD SRC OFFSET:
|
||||||
|
L2_PAYLOAD: 0 1 2 3 4 5 6 ...
|
||||||
|
L3_PAYLOAD: 0 1 2 3 4 5 6 ...
|
||||||
|
L4_PAYLOAD: 0 1 2 3 4 5 6 ...
|
||||||
|
FLEX MASK CFG:
|
||||||
|
ipv4-udp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
ipv4-tcp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
ipv4-sctp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
ipv4-other: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
ipv4-frag: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
ipv6-udp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
ipv6-tcp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
ipv6-sctp: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
ipv6-other: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
ipv6-frag: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
l2_payload: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
|
||||||
|
guarant_count: 1 best_count: 0
|
||||||
|
guarant_space: 512 best_space: 7168
|
||||||
|
collision: 0 free: 0
|
||||||
|
maxhash: 0 maxlen: 0
|
||||||
|
add: 0 remove: 0
|
||||||
|
f_add: 0 f_remove: 0
|
||||||
|
|
||||||
|
|
||||||
|
Delete all flow director rules on a port:
|
||||||
|
|
||||||
|
.. code-block:: console
|
||||||
|
|
||||||
|
testpmd> flush_flow_director 0
|
||||||
|
|
@ -41,6 +41,7 @@ Network Interface Controller Drivers
|
|||||||
e1000em
|
e1000em
|
||||||
enic
|
enic
|
||||||
fm10k
|
fm10k
|
||||||
|
i40e
|
||||||
ixgbe
|
ixgbe
|
||||||
intel_vf
|
intel_vf
|
||||||
mlx4
|
mlx4
|
||||||
|
@ -86,61 +86,61 @@ Most of these differences are summarized below.
|
|||||||
e e e e e e
|
e e e e e e
|
||||||
c c c c c c
|
c c c c c c
|
||||||
==================== = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
|
==================== = = = = = = = = = = = = = = = = = = = = = = = = = = = = = = =
|
||||||
link status
|
link status X X
|
||||||
link status event
|
link status event X X
|
||||||
Rx interrupt
|
Rx interrupt X X X X
|
||||||
queue start/stop
|
queue start/stop X X X X
|
||||||
MTU update
|
MTU update
|
||||||
jumbo frame
|
jumbo frame X X X X
|
||||||
scattered Rx
|
scattered Rx X X X X
|
||||||
LRO
|
LRO
|
||||||
TSO
|
TSO X X X X
|
||||||
promiscuous mode
|
promiscuous mode X X X X
|
||||||
allmulticast mode
|
allmulticast mode X X X X
|
||||||
unicast MAC filter
|
unicast MAC filter X X X X
|
||||||
multicast MAC filter
|
multicast MAC filter X X X X
|
||||||
RSS hash
|
RSS hash X X X X
|
||||||
RSS key update
|
RSS key update X X X X
|
||||||
RSS reta update
|
RSS reta update X X X X
|
||||||
VMDq
|
VMDq X X
|
||||||
SR-IOV
|
SR-IOV X X
|
||||||
DCB
|
DCB X X
|
||||||
VLAN filter
|
VLAN filter X X X X
|
||||||
ethertype filter
|
ethertype filter X X
|
||||||
n-tuple filter
|
n-tuple filter
|
||||||
SYN filter
|
SYN filter
|
||||||
tunnel filter
|
tunnel filter X X
|
||||||
flexible filter
|
flexible filter
|
||||||
hash filter
|
hash filter X X X X
|
||||||
flow director
|
flow director X X
|
||||||
flow control
|
flow control X X
|
||||||
rate limitation
|
rate limitation
|
||||||
traffic mirroring
|
traffic mirroring X X
|
||||||
CRC offload
|
CRC offload X X
|
||||||
VLAN offload
|
VLAN offload X X
|
||||||
QinQ offload
|
QinQ offload X X
|
||||||
L3 checksum offload
|
L3 checksum offload X X
|
||||||
L4 checksum offload
|
L4 checksum offload X X
|
||||||
inner L3 checksum
|
inner L3 checksum X X
|
||||||
inner L4 checksum
|
inner L4 checksum X X
|
||||||
packet type parsing
|
packet type parsing X X
|
||||||
timesync
|
timesync X X
|
||||||
basic stats
|
basic stats X X X X
|
||||||
extended stats
|
extended stats X X X X
|
||||||
stats per queue
|
stats per queue
|
||||||
EEPROM dump
|
EEPROM dump
|
||||||
registers dump
|
registers dump
|
||||||
multiprocess aware
|
multiprocess aware X X X X
|
||||||
BSD nic_uio
|
BSD nic_uio X X X X
|
||||||
Linux UIO
|
Linux UIO X X X X
|
||||||
Linux VFIO
|
Linux VFIO X X X X
|
||||||
other kdrv
|
other kdrv
|
||||||
ARMv7
|
ARMv7
|
||||||
ARMv8
|
ARMv8
|
||||||
Power8
|
Power8
|
||||||
TILE-Gx
|
TILE-Gx
|
||||||
x86-32
|
x86-32 X X X X
|
||||||
x86-64
|
x86-64 X X X X
|
||||||
usage doc
|
usage doc
|
||||||
design doc
|
design doc
|
||||||
perf doc
|
perf doc
|
||||||
|
Loading…
x
Reference in New Issue
Block a user