app/testpmd: add missing autoneg field to set flow control

Following commit 2d95b84aaacb3d2d0bd70367c0530d15e0cbb14e, rte_eth_fc_conf
struct contains a autoneg field that must be set by callers.
Add this parameter to testpmd.

Signed-off-by: David Marchand <david.marchand@6wind.com>
Acked-by: Thomas Monjalon <thomas.monjalon@6wind.com>
This commit is contained in:
David Marchand 2014-06-24 15:06:50 +02:00 committed by Thomas Monjalon
parent b024956a23
commit 3ebb09d02f

View File

@ -326,7 +326,7 @@ static void cmd_help_long_parsed(void *parsed_result,
"set flow_ctrl rx (on|off) tx (on|off) (high_water)"
" (low_water) (pause_time) (send_xon) mac_ctrl_frame_fwd"
" (on|off) (port_id)\n"
" (on|off) autoneg (on|off) (port_id)\n"
" Set the link flow control parameter on a port.\n\n"
"set pfc_ctrl rx (on|off) tx (on|off) (high_water)"
@ -3814,6 +3814,8 @@ struct cmd_link_flow_ctrl_set_result {
cmdline_fixed_string_t tx_lfc_mode;
cmdline_fixed_string_t mac_ctrl_frame_fwd;
cmdline_fixed_string_t mac_ctrl_frame_fwd_mode;
cmdline_fixed_string_t autoneg_str;
cmdline_fixed_string_t autoneg;
uint32_t high_water;
uint32_t low_water;
uint16_t pause_time;
@ -3851,6 +3853,7 @@ cmd_link_flow_ctrl_set_parsed(void *parsed_result,
fc_conf.pause_time = res->pause_time;
fc_conf.send_xon = res->send_xon;
fc_conf.mac_ctrl_frame_fwd = (uint8_t)mac_ctrl_frame_fwd;
fc_conf.autoneg = (!strcmp(res->autoneg, "on")) ? 1 : 0;
ret = rte_eth_dev_flow_ctrl_set(res->port_id, &fc_conf);
if (ret != 0)
@ -3893,6 +3896,12 @@ cmdline_parse_token_string_t cmd_lfc_set_mac_ctrl_frame_fwd_mode =
cmdline_parse_token_string_t cmd_lfc_set_mac_ctrl_frame_fwd =
TOKEN_STRING_INITIALIZER(struct cmd_link_flow_ctrl_set_result,
mac_ctrl_frame_fwd_mode, "on#off");
cmdline_parse_token_string_t cmd_lfc_set_autoneg_str =
TOKEN_STRING_INITIALIZER(struct cmd_link_flow_ctrl_set_result,
autoneg_str, "autoneg");
cmdline_parse_token_string_t cmd_lfc_set_autoneg =
TOKEN_STRING_INITIALIZER(struct cmd_link_flow_ctrl_set_result,
autoneg, "on#off");
cmdline_parse_token_num_t cmd_lfc_set_portid =
TOKEN_NUM_INITIALIZER(struct cmd_link_flow_ctrl_set_result,
port_id, UINT8);
@ -3902,7 +3911,7 @@ cmdline_parse_inst_t cmd_link_flow_control_set = {
.data = NULL,
.help_str = "Configure the Ethernet flow control: set flow_ctrl rx on|off \
tx on|off high_water low_water pause_time send_xon mac_ctrl_frame_fwd on|off \
port_id",
autoneg on|off port_id",
.tokens = {
(void *)&cmd_lfc_set_set,
(void *)&cmd_lfc_set_flow_ctrl,
@ -3916,6 +3925,8 @@ port_id",
(void *)&cmd_lfc_set_send_xon,
(void *)&cmd_lfc_set_mac_ctrl_frame_fwd_mode,
(void *)&cmd_lfc_set_mac_ctrl_frame_fwd,
(void *)&cmd_lfc_set_autoneg_str,
(void *)&cmd_lfc_set_autoneg,
(void *)&cmd_lfc_set_portid,
NULL,
},