net/sfc/base: avoid division by 0 if no event queue timers
If event queue timers are not supported, enc_evq_timer_quantum_ns and enc_evq_timer_max_us should be set to 0. Make sure that division by 0 does not happen in libefx, if public function efx_ev_usecs_to_ticks() is used in this case. Signed-off-by: Andrew Rybchenko <arybchenko@solarflare.com>
This commit is contained in:
parent
5661516f22
commit
40d2864c8a
@ -566,6 +566,12 @@ efx_ev_usecs_to_ticks(
|
||||
{
|
||||
efx_nic_cfg_t *encp = &(enp->en_nic_cfg);
|
||||
unsigned int ticks;
|
||||
efx_rc_t rc;
|
||||
|
||||
if (encp->enc_evq_timer_quantum_ns == 0) {
|
||||
rc = ENOTSUP;
|
||||
goto fail1;
|
||||
}
|
||||
|
||||
/* Convert microseconds to a timer tick count */
|
||||
if (us == 0)
|
||||
@ -577,6 +583,10 @@ efx_ev_usecs_to_ticks(
|
||||
|
||||
*ticksp = ticks;
|
||||
return (0);
|
||||
|
||||
fail1:
|
||||
EFSYS_PROBE1(fail1, efx_rc_t, rc);
|
||||
return (rc);
|
||||
}
|
||||
|
||||
__checkReturn efx_rc_t
|
||||
|