doc: improve multiport PF in nfp guide
The Agilio CX family of smartNIC's generally have a 1:many mapping of PF
to physical ports. Elaborate on this mapping in the PF multiport section
of the NFP PMD documentation.
Fixes: d625beafc8
("doc: update NFP with PF support information")
Cc: stable@dpdk.org
Signed-off-by: Heinrich Kuhn <heinrich.kuhn@netronome.com>
Signed-off-by: Simon Horman <simon.horman@netronome.com>
This commit is contained in:
parent
dca62adebf
commit
979f2bae07
@ -102,22 +102,39 @@ directory per firmware application. Options 1 and 2 for firmware filenames allow
|
||||
more than one SmartNIC, same type of SmartNIC or different ones, and to upload a
|
||||
different firmware to each SmartNIC.
|
||||
|
||||
.. Note::
|
||||
Currently the NFP PMD supports using the PF with Agilio Basic Firmware. See
|
||||
https://help.netronome.com/support/solutions for more information on the
|
||||
various firmwares supported by the Netronome Agilio CX smartNIC.
|
||||
|
||||
PF multiport support
|
||||
--------------------
|
||||
|
||||
Some NFP cards support several physical ports with just one single PCI device.
|
||||
The DPDK core is designed with a 1:1 relationship between PCI devices and DPDK
|
||||
ports, so NFP PMD PF support requires handling the multiport case specifically.
|
||||
During NFP PF initialization, the PMD will extract the information about the
|
||||
number of PF ports from the firmware and will create as many DPDK ports as
|
||||
needed.
|
||||
The NFP PMD can work with up to 8 ports on the same PF device. The number of
|
||||
available ports is firmware and hardware dependent, and the driver looks for a
|
||||
firmware symbol during initialization to know how many can be used.
|
||||
|
||||
Because the unusual relationship between a single PCI device and several DPDK
|
||||
ports, there are some limitations when using more than one PF DPDK port: there
|
||||
is no support for RX interrupts and it is not possible either to use those PF
|
||||
ports with the device hotplug functionality.
|
||||
DPDK apps work with ports, and a port is usually a PF or a VF PCI device.
|
||||
However, with the NFP PF multiport there is just one PF PCI device. Supporting
|
||||
this particular configuration requires the PMD to create ports in a special way,
|
||||
although once they are created, DPDK apps should be able to use them as normal
|
||||
PCI ports.
|
||||
|
||||
NFP ports belonging to same PF can be seen inside PMD initialization with a
|
||||
suffix added to the PCI ID: wwww:xx:yy.z_port_n. For example, a PF with PCI ID
|
||||
0000:03:00.0 and four ports is seen by the PMD code as:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
0000:03:00.0_port_0
|
||||
0000:03:00.0_port_1
|
||||
0000:03:00.0_port_2
|
||||
0000:03:00.0_port_3
|
||||
|
||||
.. Note::
|
||||
|
||||
There are some limitations with multiport support: RX interrupts and
|
||||
device hot-plugging are not supported.
|
||||
|
||||
PF multiprocess support
|
||||
-----------------------
|
||||
|
Loading…