doc: fix spelling in i40e guide
This patch corrects some spelling issues in i40e.rst and clarifies which controllers and connections are part of the 700 Series. Signed-off-by: Qiming Yang <qiming.yang@intel.com> Acked-by: Marko Kovacevic <marko.kovacevic@intel.com>
This commit is contained in:
parent
515e92ebb6
commit
aa4cef698c
@ -4,14 +4,16 @@
|
||||
I40E Poll Mode Driver
|
||||
======================
|
||||
|
||||
The I40E PMD (librte_pmd_i40e) provides poll mode driver support
|
||||
for the Intel X710/XL710/X722/XXV710 10/25/40 Gbps family of adapters.
|
||||
The i40e PMD (librte_pmd_i40e) provides poll mode driver support for
|
||||
10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
|
||||
the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
|
||||
Connection X722 (only support part of features).
|
||||
|
||||
|
||||
Features
|
||||
--------
|
||||
|
||||
Features of the I40E PMD are:
|
||||
Features of the i40e PMD are:
|
||||
|
||||
- Multiple queues for TX and RX
|
||||
- Receiver Side Scaling (RSS)
|
||||
@ -40,7 +42,7 @@ Features of the I40E PMD are:
|
||||
- VF Daemon (VFD) - EXPERIMENTAL
|
||||
- Dynamic Device Personalization (DDP)
|
||||
- Queue region configuration
|
||||
- Vitrual Function Port Representors
|
||||
- Virtual Function Port Representors
|
||||
|
||||
Prerequisites
|
||||
-------------
|
||||
@ -54,7 +56,7 @@ Prerequisites
|
||||
section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
|
||||
|
||||
- Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
|
||||
<https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ if needed.
|
||||
<https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
|
||||
|
||||
Pre-Installation Configuration
|
||||
------------------------------
|
||||
@ -339,7 +341,7 @@ Delete all flow director rules on a port:
|
||||
Floating VEB
|
||||
~~~~~~~~~~~~~
|
||||
|
||||
The Intel® Ethernet Controller X710 and XL710 Family support a feature called
|
||||
The Intel® Ethernet 700 Series support a feature called
|
||||
"Floating VEB".
|
||||
|
||||
A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
|
||||
@ -385,21 +387,22 @@ or greater.
|
||||
Dynamic Device Personalization (DDP)
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The Intel® Ethernet Controller X*710 support a feature called "Dynamic Device
|
||||
Personalization (DDP)", which is used to configure hardware by downloading
|
||||
a profile to support protocols/filters which are not supported by default.
|
||||
The DDP functionality requires a NIC firmware version of 6.0 or greater.
|
||||
The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
|
||||
X722 support a feature called "Dynamic Device Personalization (DDP)",
|
||||
which is used to configure hardware by downloading a profile to support
|
||||
protocols/filters which are not supported by default. The DDP
|
||||
functionality requires a NIC firmware version of 6.0 or greater.
|
||||
|
||||
Current implementation supports MPLSoUDP/MPLSoGRE/GTP-C/GTP-U/PPPoE/PPPoL2TP,
|
||||
Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP,
|
||||
steering can be used with rte_flow API.
|
||||
|
||||
Load a profile which supports MPLSoUDP/MPLSoGRE and store backup profile:
|
||||
Load a profile which supports GTP and store backup profile:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
testpmd> ddp add 0 ./mpls.pkgo,./backup.pkgo
|
||||
testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
|
||||
|
||||
Delete a MPLS profile and restore backup profile:
|
||||
Delete a GTP profile and restore backup profile:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
@ -411,11 +414,11 @@ Get loaded DDP package info list:
|
||||
|
||||
testpmd> ddp get list 0
|
||||
|
||||
Display information about a MPLS profile:
|
||||
Display information about a GTP profile:
|
||||
|
||||
.. code-block:: console
|
||||
|
||||
testpmd> ddp get info ./mpls.pkgo
|
||||
testpmd> ddp get info ./gtp.pkgo
|
||||
|
||||
Input set configuration
|
||||
~~~~~~~~~~~~~~~~~~~~~~~
|
||||
@ -431,7 +434,7 @@ For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
|
||||
|
||||
Queue region configuration
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
The Ethernet Controller X710/XL710 supports a feature of queue regions
|
||||
The Intel® Ethernet 700 Series supports a feature of queue regions
|
||||
configuration for RSS in the PF, so that different traffic classes or
|
||||
different packet classification types can be separated to different
|
||||
queues in different queue regions. There is an API for configuration
|
||||
@ -455,8 +458,8 @@ details please refer to :doc:`../testpmd_app_ug/index`.
|
||||
Limitations or Known issues
|
||||
---------------------------
|
||||
|
||||
MPLS packet classification on X710/XL710
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
MPLS packet classification
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
|
||||
The L2 Payload flow type in flow director can be used to classify MPLS packet
|
||||
@ -504,14 +507,14 @@ Incorrect Rx statistics when packet is oversize
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
When a packet is over maximum frame size, the packet is dropped.
|
||||
However the Rx statistics, when calling `rte_eth_stats_get` incorrectly
|
||||
However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
|
||||
shows it as received.
|
||||
|
||||
VF & TC max bandwidth setting
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
|
||||
The dehavior is different when handling per VF and per TC max bandwidth setting.
|
||||
The behavior is different when handling per VF and per TC max bandwidth setting.
|
||||
When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
|
||||
enabled. If so, return failure.
|
||||
When enabling per TC max bandwidth, SW will check if per VF max bandwidth
|
||||
@ -532,11 +535,11 @@ VF performance is impacted by PCI extended tag setting
|
||||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||||
|
||||
To reach maximum NIC performance in the VF the PCI extended tag must be
|
||||
enabled. The DPDK I40E PF driver will set this feature during initialization,
|
||||
enabled. The DPDK i40e PF driver will set this feature during initialization,
|
||||
but the kernel PF driver does not. So when running traffic on a VF which is
|
||||
managed by the kernel PF driver, a significant NIC performance downgrade has
|
||||
been observed (for 64 byte packets, there is about 25% linerate downgrade for
|
||||
a 25G device and about 35% for a 40G device).
|
||||
been observed (for 64 byte packets, there is about 25% line-rate downgrade for
|
||||
a 25GbE device and about 35% for a 40GbE device).
|
||||
|
||||
For kernel version >= 4.11, the kernel's PCI driver will enable the extended
|
||||
tag if it detects that the device supports it. So by default, this is not an
|
||||
@ -577,12 +580,12 @@ with DPDK, then the configuration will also impact port B in the NIC with
|
||||
kernel driver, which don't want to use the TPID.
|
||||
So PMD reports warning to clarify what is changed by writing global register.
|
||||
|
||||
High Performance of Small Packets on 40G NIC
|
||||
--------------------------------------------
|
||||
High Performance of Small Packets on 40GbE NIC
|
||||
----------------------------------------------
|
||||
|
||||
As there might be firmware fixes for performance enhancement in latest version
|
||||
of firmware image, the firmware update might be needed for getting high performance.
|
||||
Check with the local Intel's Network Division application engineers for firmware updates.
|
||||
Check the Intel support website for the latest firmware updates.
|
||||
Users should consult the release notes specific to a DPDK release to identify
|
||||
the validated firmware version for a NIC using the i40e driver.
|
||||
|
||||
@ -605,10 +608,10 @@ performance or per packet latency.
|
||||
Example of getting best performance with l3fwd example
|
||||
------------------------------------------------------
|
||||
|
||||
The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with an
|
||||
Intel server platform and Intel XL710 NICs.
|
||||
The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
|
||||
server with Intel Xeon processors and Intel Ethernet CNA XL710.
|
||||
|
||||
The example scenario is to get best performance with two Intel XL710 40GbE ports.
|
||||
The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
|
||||
See :numref:`figure_intel_perf_test_setup` for the performance test setup.
|
||||
|
||||
.. _figure_intel_perf_test_setup:
|
||||
@ -618,9 +621,9 @@ See :numref:`figure_intel_perf_test_setup` for the performance test setup.
|
||||
Performance Test Setup
|
||||
|
||||
|
||||
1. Add two Intel XL710 NICs to the platform, and use one port per card to get best performance.
|
||||
The reason for using two NICs is to overcome a PCIe Gen3's limitation since it cannot provide 80G bandwidth
|
||||
for two 40G ports, but two different PCIe Gen3 x8 slot can.
|
||||
1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
|
||||
The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
|
||||
for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
|
||||
Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
|
||||
|
||||
82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
|
||||
@ -636,7 +639,7 @@ See :numref:`figure_intel_perf_test_setup` for the performance test setup.
|
||||
|
||||
4. Bind these two ports to igb_uio.
|
||||
|
||||
5. As to XL710 40G port, we need at least two queue pairs to achieve best performance, then two queues per port
|
||||
5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
|
||||
will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
|
||||
|
||||
6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
|
||||
|