net/bnxt: use vport in PHY port action handler
The phy port action handler should get vport details and not vnic id. The fix is to calculate the vport of the given port. Signed-off-by: Kishore Padmanabha <kishore.padmanabha@broadcom.com> Signed-off-by: Somnath Kotur <somnath.kotur@broadcom.com> Reviewed-by: Mike Baucom <michael.baucom@broadcom.com> Reviewed-by: Ajit Khaparde <ajit.khaparde@broadcom.com>
This commit is contained in:
parent
8608c099d1
commit
ae33d634e6
@ -1284,7 +1284,7 @@ ulp_rte_phy_port_act_handler(const struct rte_flow_action *action_item,
|
||||
struct ulp_rte_parser_params *prm)
|
||||
{
|
||||
const struct rte_flow_action_phy_port *phy_port;
|
||||
uint32_t pid;
|
||||
uint32_t vport;
|
||||
|
||||
phy_port = action_item->conf;
|
||||
if (phy_port) {
|
||||
@ -1293,10 +1293,12 @@ ulp_rte_phy_port_act_handler(const struct rte_flow_action *action_item,
|
||||
"Parse Err:Port Original not supported\n");
|
||||
return BNXT_TF_RC_PARSE_ERR;
|
||||
}
|
||||
pid = bnxt_get_vnic_id(phy_port->index);
|
||||
pid = rte_cpu_to_be_32(pid);
|
||||
/* Get the vport of the physical port */
|
||||
/* TBD: shall be changed later to portdb call */
|
||||
vport = 1 << phy_port->index;
|
||||
vport = rte_cpu_to_be_32(vport);
|
||||
memcpy(&prm->act_prop.act_details[BNXT_ULP_ACT_PROP_IDX_VPORT],
|
||||
&pid, BNXT_ULP_ACT_PROP_SZ_VPORT);
|
||||
&vport, BNXT_ULP_ACT_PROP_SZ_VPORT);
|
||||
}
|
||||
|
||||
/* Update the hdr_bitmap with count */
|
||||
|