net/e1000/base: modify flow control setup

Customers had a problem with large pings after connected standby.
This is due to the requirement of maintaining link after CS - the driver
blocks resets during "AdapterStart" and skips flow control setup.
Added condition in e1000_setup_link_ich8lan.c function that always setup
flow control, and setup physical interface only when no need to block
resets.

Signed-off-by: Nir Efrati <nir.efrati@intel.com>
Signed-off-by: Guinan Sun <guinanx.sun@intel.com>
Reviewed-by: Wei Zhao <wei.zhao1@intel.com>
This commit is contained in:
Guinan Sun 2020-07-06 08:12:14 +00:00 committed by Ferruh Yigit
parent fc9933953c
commit c3c9fe3699

View File

@ -5200,9 +5200,6 @@ STATIC s32 e1000_setup_link_ich8lan(struct e1000_hw *hw)
DEBUGFUNC("e1000_setup_link_ich8lan");
if (hw->phy.ops.check_reset_block(hw))
return E1000_SUCCESS;
/* ICH parts do not have a word in the NVM to determine
* the default flow control setting, so we explicitly
* set it to full.
@ -5218,10 +5215,12 @@ STATIC s32 e1000_setup_link_ich8lan(struct e1000_hw *hw)
DEBUGOUT1("After fix-ups FlowControl is now = %x\n",
hw->fc.current_mode);
if (!hw->phy.ops.check_reset_block(hw)) {
/* Continue to configure the copper link. */
ret_val = hw->mac.ops.setup_physical_interface(hw);
if (ret_val)
return ret_val;
}
E1000_WRITE_REG(hw, E1000_FCTTV, hw->fc.pause_time);
if ((hw->phy.type == e1000_phy_82578) ||