Wei Hu (Xavier)
a951c1ed3a net/hns3: support different numbers of Rx and Tx queues
Hardware does not support individually enable/disable/reset the Tx or Rx
queue in hns3 network engine, driver must enable/disable/reset Tx and Rx
queues at the same time.

Currently, hns3 PMD driver does not support the scenarios as below:
1) When calling the following function, the input parameter nb_rx_q and
   nb_tx_q are not equal.
     rte_eth_dev_configure(uint16_t port_id, uint16_t nb_rx_q,
                      uint16_t nb_tx_q,
		      const struct rte_eth_conf *dev_conf);
2) When calling the following functions to setup queues, the
   cumulatively setup Rx queues are not the same as the setup Tx queues.
     rte_eth_rx_queue_setup(uint16_t port_id, uint16_t rx_queue_id,,,);
     rte_eth_tx_queue_setup(uint16_t port_id, uint16_t tx_queue_id,,,);
However, these are common usage scenarios in some applications, such as,
l3fwd, ip_ressmbly and OVS-DPDK, etc.

This patch adds support for this usage of these functions by setup fake
Tx or Rx queues to adjust numbers of Tx/Rx queues. But these fake queues
are imperceptible, and can not be used by upper applications.

Signed-off-by: Huisong Li <lihuisong@huawei.com>
Signed-off-by: Wei Hu (Xavier) <xavier.huwei@huawei.com>
2020-01-17 19:46:26 +01:00
Wei Hu (Xavier)
62e3ccc2b9 net/hns3: support flow control
This patch adds support for MAC PAUSE flow control and priority flow
control(PFC).

MAC PAUSE flow control features:
All user priorities(up) are mapped to tc0. It supports settings of flow
mode and pause time.

DCB features:
Up can be mapped to other tc driver permits according to business
requirement. We can config DCB information and enable PFC by
rte_eth_dev_configure interface. Besides, enabling flow control of a
priority is supported by rte_eth_dev_priority_flow_ctrl_set interface.
we can also set flow mode and pause time by
rte_eth_dev_priority_flow_ctrl_set. we do not support manual setting of
ETS, but driver equally distributes bandwidth for each tc according to
number of used tc.

In addition, flow control function by default is turned off to ensure
that app startup state is the same each time.

Signed-off-by: Huisong Li <lihuisong@huawei.com>
Signed-off-by: Wei Hu (Xavier) <xavier.huwei@huawei.com>
Signed-off-by: Chunsong Feng <fengchunsong@huawei.com>
Signed-off-by: Min Hu (Connor) <humin29@huawei.com>
Signed-off-by: Hao Chen <chenhao164@huawei.com>
Reviewed-by: Ferruh Yigit <ferruh.yigit@intel.com>
2019-10-07 15:00:56 +02:00