// SPDX-License-Identifier: BSD-3-Clause /* * Copyright 2018 Mellanox Technologies, Ltd */ #include #include #include #include #include #include #include #include "mlx5.h" #include "mlx5_flow.h" /** * Create the meter action. * * @param priv * Pointer to mlx5_priv. * @param[in] fm * Pointer to flow meter to be converted. * * @return * Pointer to the meter action on success, NULL otherwise. */ static void * mlx5_flow_meter_action_create(struct mlx5_priv *priv, struct mlx5_flow_meter_info *fm) { #ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER struct mlx5dv_dr_flow_meter_attr mtr_init; uint32_t fmp[MLX5_ST_SZ_DW(flow_meter_parameters)]; struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm = &fm->profile->srtcm_prm; uint32_t cbs_cir = rte_be_to_cpu_32(srtcm->cbs_cir); uint32_t ebs_eir = rte_be_to_cpu_32(srtcm->ebs_eir); uint32_t val; enum mlx5_meter_domain domain = fm->transfer ? MLX5_MTR_DOMAIN_TRANSFER : fm->egress ? MLX5_MTR_DOMAIN_EGRESS : MLX5_MTR_DOMAIN_INGRESS; struct mlx5_flow_meter_def_policy *def_policy = priv->sh->mtrmng->def_policy[domain]; memset(fmp, 0, MLX5_ST_SZ_BYTES(flow_meter_parameters)); MLX5_SET(flow_meter_parameters, fmp, valid, 1); MLX5_SET(flow_meter_parameters, fmp, bucket_overflow, 1); MLX5_SET(flow_meter_parameters, fmp, start_color, MLX5_FLOW_COLOR_GREEN); MLX5_SET(flow_meter_parameters, fmp, both_buckets_on_green, 0); val = (cbs_cir >> ASO_DSEG_CBS_EXP_OFFSET) & ASO_DSEG_EXP_MASK; MLX5_SET(flow_meter_parameters, fmp, cbs_exponent, val); val = (cbs_cir >> ASO_DSEG_CBS_MAN_OFFSET) & ASO_DSEG_MAN_MASK; MLX5_SET(flow_meter_parameters, fmp, cbs_mantissa, val); val = (cbs_cir >> ASO_DSEG_CIR_EXP_OFFSET) & ASO_DSEG_EXP_MASK; MLX5_SET(flow_meter_parameters, fmp, cir_exponent, val); val = (cbs_cir & ASO_DSEG_MAN_MASK); MLX5_SET(flow_meter_parameters, fmp, cir_mantissa, val); val = (ebs_eir >> ASO_DSEG_EBS_EXP_OFFSET) & ASO_DSEG_EXP_MASK; MLX5_SET(flow_meter_parameters, fmp, ebs_exponent, val); val = (ebs_eir >> ASO_DSEG_EBS_MAN_OFFSET) & ASO_DSEG_MAN_MASK; MLX5_SET(flow_meter_parameters, fmp, ebs_mantissa, val); mtr_init.next_table = def_policy->sub_policy.tbl_rsc->obj; mtr_init.reg_c_index = priv->mtr_color_reg - REG_C_0; mtr_init.flow_meter_parameter = fmp; mtr_init.flow_meter_parameter_sz = MLX5_ST_SZ_BYTES(flow_meter_parameters); mtr_init.active = fm->active_state; return mlx5_glue->dv_create_flow_action_meter(&mtr_init); #else (void)priv; (void)fm; return NULL; #endif } /** * Find meter profile by id. * * @param priv * Pointer to mlx5_priv. * @param meter_profile_id * Meter profile id. * * @return * Pointer to the profile found on success, NULL otherwise. */ static struct mlx5_flow_meter_profile * mlx5_flow_meter_profile_find(struct mlx5_priv *priv, uint32_t meter_profile_id) { struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles; struct mlx5_flow_meter_profile *fmp; TAILQ_FOREACH(fmp, fmps, next) if (meter_profile_id == fmp->id) return fmp; return NULL; } /** * Validate the MTR profile. * * @param[in] dev * Pointer to Ethernet device. * @param[in] meter_profile_id * Meter profile id. * @param[in] profile * Pointer to meter profile detail. * @param[out] error * Pointer to the error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_profile_validate(struct rte_eth_dev *dev, uint32_t meter_profile_id, struct rte_mtr_meter_profile *profile, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_profile *fmp; /* Profile must not be NULL. */ if (profile == NULL) return -rte_mtr_error_set(error, EINVAL, RTE_MTR_ERROR_TYPE_METER_PROFILE, NULL, "Meter profile is null."); /* Meter profile ID must be valid. */ if (meter_profile_id == UINT32_MAX) return -rte_mtr_error_set(error, EINVAL, RTE_MTR_ERROR_TYPE_METER_PROFILE_ID, NULL, "Meter profile id not valid."); /* Meter profile must not exist. */ fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id); if (fmp) return -rte_mtr_error_set(error, EEXIST, RTE_MTR_ERROR_TYPE_METER_PROFILE_ID, NULL, "Meter profile already exists."); if (profile->alg == RTE_MTR_SRTCM_RFC2697) { if (priv->config.hca_attr.qos.flow_meter_old) { /* Verify support for flow meter parameters. */ if (priv->sh->meter_aso_en && profile->packet_mode) { if (profile->srtcm_rfc2697.cir > 0 && (profile->srtcm_rfc2697.cir << MLX5_MTRS_PPS_MAP_BPS_SHIFT) <= MLX5_SRTCM_CIR_MAX && profile->srtcm_rfc2697.cbs > 0 && (profile->srtcm_rfc2697.cbs << MLX5_MTRS_PPS_MAP_BPS_SHIFT) <= MLX5_SRTCM_CBS_MAX && (profile->srtcm_rfc2697.ebs << MLX5_MTRS_PPS_MAP_BPS_SHIFT) <= MLX5_SRTCM_EBS_MAX) return 0; return -rte_mtr_error_set (error, ENOTSUP, RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL, profile->srtcm_rfc2697.ebs ? "Metering value ebs must be 0." : "Invalid metering parameters."); } if (profile->srtcm_rfc2697.cir > 0 && profile->srtcm_rfc2697.cir <= MLX5_SRTCM_CIR_MAX && profile->srtcm_rfc2697.cbs > 0 && profile->srtcm_rfc2697.cbs <= MLX5_SRTCM_CBS_MAX && profile->srtcm_rfc2697.ebs <= MLX5_SRTCM_EBS_MAX) return 0; return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL, profile->srtcm_rfc2697.ebs ? "Metering value ebs must be 0." : "Invalid metering parameters."); } } return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_PROFILE, NULL, "Metering algorithm not supported."); } /** * Calculate mantissa and exponent for cir. * * @param[in] cir * Value to be calculated. * @param[out] man * Pointer to the mantissa. * @param[out] exp * Pointer to the exp. */ static void mlx5_flow_meter_cir_man_exp_calc(int64_t cir, uint8_t *man, uint8_t *exp) { int64_t _cir; int64_t delta = INT64_MAX; uint8_t _man = 0; uint8_t _exp = 0; uint64_t m, e; for (m = 0; m <= 0xFF; m++) { /* man width 8 bit */ for (e = 0; e <= 0x1F; e++) { /* exp width 5bit */ _cir = (1000000000ULL * m) >> e; if (llabs(cir - _cir) <= delta) { delta = llabs(cir - _cir); _man = m; _exp = e; } } } *man = _man; *exp = _exp; } /** * Calculate mantissa and exponent for xbs. * * @param[in] xbs * Value to be calculated. * @param[out] man * Pointer to the mantissa. * @param[out] exp * Pointer to the exp. */ static void mlx5_flow_meter_xbs_man_exp_calc(uint64_t xbs, uint8_t *man, uint8_t *exp) { int _exp; double _man; /* Special case xbs == 0 ? both exp and matissa are 0. */ if (xbs == 0) { *man = 0; *exp = 0; return; } /* xbs = xbs_mantissa * 2^xbs_exponent */ _man = frexp(xbs, &_exp); _man = _man * pow(2, MLX5_MAN_WIDTH); _exp = _exp - MLX5_MAN_WIDTH; *man = (uint8_t)ceil(_man); *exp = _exp; } /** * Fill the prm meter parameter. * * @param[in,out] fmp * Pointer to meter profie to be converted. * @param[out] error * Pointer to the error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_param_fill(struct mlx5_flow_meter_profile *fmp, struct mlx5_priv *priv, struct rte_mtr_error *error) { struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm = &fmp->srtcm_prm; uint8_t man, exp; uint32_t cbs_exp, cbs_man, cir_exp, cir_man; uint32_t ebs_exp, ebs_man; uint64_t cir, cbs, ebs; if (fmp->profile.alg != RTE_MTR_SRTCM_RFC2697) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_PROFILE, NULL, "Metering algorithm not supported."); if (!priv->sh->meter_aso_en && fmp->profile.packet_mode) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_PROFILE, NULL, "Metering algorithm packet mode not supported."); if (priv->sh->meter_aso_en && fmp->profile.packet_mode) { cir = fmp->profile.srtcm_rfc2697.cir << MLX5_MTRS_PPS_MAP_BPS_SHIFT; cbs = fmp->profile.srtcm_rfc2697.cbs << MLX5_MTRS_PPS_MAP_BPS_SHIFT; ebs = fmp->profile.srtcm_rfc2697.ebs << MLX5_MTRS_PPS_MAP_BPS_SHIFT; } else { cir = fmp->profile.srtcm_rfc2697.cir; cbs = fmp->profile.srtcm_rfc2697.cbs; ebs = fmp->profile.srtcm_rfc2697.ebs; } /* cir = 8G * cir_mantissa * 1/(2^cir_exponent)) Bytes/Sec */ mlx5_flow_meter_cir_man_exp_calc(cir, &man, &exp); /* Check if cir mantissa is too large. */ if (exp > ASO_DSEG_CIR_EXP_MASK) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL, "meter profile parameter cir is" " not supported."); cir_man = man; cir_exp = exp; /* cbs = cbs_mantissa * 2^cbs_exponent */ mlx5_flow_meter_xbs_man_exp_calc(cbs, &man, &exp); /* Check if cbs mantissa is too large. */ if (exp > ASO_DSEG_EXP_MASK) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL, "meter profile parameter cbs is" " not supported."); cbs_man = man; cbs_exp = exp; srtcm->cbs_cir = rte_cpu_to_be_32(cbs_exp << ASO_DSEG_CBS_EXP_OFFSET | cbs_man << ASO_DSEG_CBS_MAN_OFFSET | cir_exp << ASO_DSEG_CIR_EXP_OFFSET | cir_man); mlx5_flow_meter_xbs_man_exp_calc(ebs, &man, &exp); /* Check if ebs mantissa is too large. */ if (exp > ASO_DSEG_EXP_MASK) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL, "meter profile parameter ebs is" " not supported."); ebs_man = man; ebs_exp = exp; srtcm->ebs_eir = rte_cpu_to_be_32(ebs_exp << ASO_DSEG_EBS_EXP_OFFSET | ebs_man << ASO_DSEG_EBS_MAN_OFFSET); return 0; } /** * Callback to get MTR capabilities. * * @param[in] dev * Pointer to Ethernet device. * @param[out] cap * Pointer to save MTR capabilities. * @param[out] error * Pointer to the error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_mtr_cap_get(struct rte_eth_dev *dev, struct rte_mtr_capabilities *cap, struct rte_mtr_error *error __rte_unused) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_hca_qos_attr *qattr = &priv->config.hca_attr.qos; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter is not supported"); memset(cap, 0, sizeof(*cap)); if (priv->sh->meter_aso_en) { /* 2 meters per one ASO cache line. */ cap->n_max = 1 << (qattr->log_max_num_meter_aso + 1); cap->srtcm_rfc2697_packet_mode_supported = 1; } else { cap->n_max = 1 << qattr->log_max_flow_meter; cap->srtcm_rfc2697_packet_mode_supported = 0; } cap->srtcm_rfc2697_byte_mode_supported = 1; cap->n_shared_max = cap->n_max; cap->identical = 1; cap->shared_identical = 1; cap->shared_n_flows_per_mtr_max = 4 << 20; /* 2M flows can share the same meter. */ cap->chaining_n_mtrs_per_flow_max = 1; /* Chaining is not supported. */ cap->meter_srtcm_rfc2697_n_max = qattr->flow_meter_old ? cap->n_max : 0; cap->meter_rate_max = 1ULL << 40; /* 1 Tera tokens per sec. */ cap->stats_mask = RTE_MTR_STATS_N_BYTES_DROPPED | RTE_MTR_STATS_N_PKTS_DROPPED; return 0; } /** * Callback to add MTR profile. * * @param[in] dev * Pointer to Ethernet device. * @param[in] meter_profile_id * Meter profile id. * @param[in] profile * Pointer to meter profile detail. * @param[out] error * Pointer to the error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_profile_add(struct rte_eth_dev *dev, uint32_t meter_profile_id, struct rte_mtr_meter_profile *profile, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles; struct mlx5_flow_meter_profile *fmp; int ret; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter is not supported"); /* Check input params. */ ret = mlx5_flow_meter_profile_validate(dev, meter_profile_id, profile, error); if (ret) return ret; /* Meter profile memory allocation. */ fmp = mlx5_malloc(MLX5_MEM_ZERO, sizeof(struct mlx5_flow_meter_profile), RTE_CACHE_LINE_SIZE, SOCKET_ID_ANY); if (fmp == NULL) return -rte_mtr_error_set(error, ENOMEM, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter profile memory " "alloc failed."); /* Fill profile info. */ fmp->id = meter_profile_id; fmp->profile = *profile; /* Fill the flow meter parameters for the PRM. */ ret = mlx5_flow_meter_param_fill(fmp, priv, error); if (ret) goto error; /* Add to list. */ TAILQ_INSERT_TAIL(fmps, fmp, next); return 0; error: mlx5_free(fmp); return ret; } /** * Callback to delete MTR profile. * * @param[in] dev * Pointer to Ethernet device. * @param[in] meter_profile_id * Meter profile id. * @param[out] error * Pointer to the error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_profile_delete(struct rte_eth_dev *dev, uint32_t meter_profile_id, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_profile *fmp; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter is not supported"); /* Meter profile must exist. */ fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id); if (fmp == NULL) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_METER_PROFILE_ID, &meter_profile_id, "Meter profile id is invalid."); /* Check profile is unused. */ if (fmp->ref_cnt) return -rte_mtr_error_set(error, EBUSY, RTE_MTR_ERROR_TYPE_METER_PROFILE_ID, NULL, "Meter profile is in use."); /* Remove from list. */ TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next); mlx5_free(fmp); return 0; } /** * Find policy by id. * * @param[in] dev * Pointer to Ethernet device. * @param policy_id * Policy id. * * @return * Pointer to the policy found on success, NULL otherwise. */ struct mlx5_flow_meter_policy * mlx5_flow_meter_policy_find(struct rte_eth_dev *dev, uint32_t policy_id, uint32_t *policy_idx) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_sub_policy *sub_policy = NULL; union mlx5_l3t_data data; if (policy_id > MLX5_MAX_SUB_POLICY_TBL_NUM || !priv->sh->mtrmng->policy_idx_tbl) return NULL; if (mlx5_l3t_get_entry(priv->sh->mtrmng->policy_idx_tbl, policy_id, &data) || !data.dword) return NULL; if (policy_idx) *policy_idx = data.dword; sub_policy = mlx5_ipool_get(priv->sh->ipool[MLX5_IPOOL_MTR_POLICY], data.dword); /* Remove reference taken by the mlx5_l3t_get_entry. */ mlx5_l3t_clear_entry(priv->sh->mtrmng->policy_idx_tbl, policy_id); if (sub_policy) if (sub_policy->main_policy_id) return sub_policy->main_policy; return NULL; } /** * Callback to check MTR policy action validate * * @param[in] dev * Pointer to Ethernet device. * @param[in] actions * Pointer to meter policy action detail. * @param[out] error * Pointer to the error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_policy_validate(struct rte_eth_dev *dev, struct rte_mtr_meter_policy_params *policy, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct rte_flow_attr attr = { .transfer = priv->config.dv_esw_en ? 1 : 0}; bool is_rss = false; bool is_def_policy = false; uint8_t domain_bitmap; int ret; if (!priv->mtr_en || !priv->sh->meter_aso_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_POLICY, NULL, "meter policy unsupported."); ret = mlx5_flow_validate_mtr_acts(dev, policy->actions, &attr, &is_rss, &domain_bitmap, &is_def_policy, error); if (ret) return ret; return 0; } static int __mlx5_flow_meter_policy_delete(struct rte_eth_dev *dev, uint32_t policy_id, struct mlx5_flow_meter_policy *mtr_policy, struct rte_mtr_error *error, bool clear_l3t) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_sub_policy *sub_policy; uint32_t i, j; uint16_t sub_policy_num; rte_spinlock_lock(&mtr_policy->sl); if (mtr_policy->ref_cnt) { rte_spinlock_unlock(&mtr_policy->sl); return -rte_mtr_error_set(error, EBUSY, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "Meter policy object is being used."); } mlx5_flow_destroy_policy_rules(dev, mtr_policy); mlx5_flow_destroy_mtr_acts(dev, mtr_policy); for (i = 0; i < MLX5_MTR_DOMAIN_MAX; i++) { sub_policy_num = (mtr_policy->sub_policy_num >> (MLX5_MTR_SUB_POLICY_NUM_SHIFT * i)) & MLX5_MTR_SUB_POLICY_NUM_MASK; if (sub_policy_num) { for (j = 0; j < sub_policy_num; j++) { sub_policy = mtr_policy->sub_policys[i][j]; if (sub_policy) mlx5_ipool_free (priv->sh->ipool[MLX5_IPOOL_MTR_POLICY], sub_policy->idx); } } } if (priv->sh->mtrmng->policy_idx_tbl && clear_l3t) { if (mlx5_l3t_clear_entry(priv->sh->mtrmng->policy_idx_tbl, policy_id)) { rte_spinlock_unlock(&mtr_policy->sl); return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "Fail to delete policy in index table."); } } rte_spinlock_unlock(&mtr_policy->sl); return 0; } /** * Callback to add MTR policy. * * @param[in] dev * Pointer to Ethernet device. * @param[out] policy_id * Pointer to policy id * @param[in] actions * Pointer to meter policy action detail. * @param[out] error * Pointer to the error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_policy_add(struct rte_eth_dev *dev, uint32_t policy_id, struct rte_mtr_meter_policy_params *policy, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct rte_flow_attr attr = { .transfer = priv->config.dv_esw_en ? 1 : 0}; uint32_t sub_policy_idx = 0; uint32_t policy_idx = 0; struct mlx5_flow_meter_policy *mtr_policy = NULL; struct mlx5_flow_meter_sub_policy *sub_policy; bool is_rss = false; bool is_def_policy = false; uint32_t i; int ret; uint32_t policy_size = sizeof(struct mlx5_flow_meter_policy); uint16_t sub_policy_num; uint8_t domain_bitmap = 0; union mlx5_l3t_data data; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_POLICY, NULL, "meter policy unsupported."); if (policy_id == MLX5_INVALID_POLICY_ID) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "policy ID is invalid. "); if (policy_id == priv->sh->mtrmng->def_policy_id) return -rte_mtr_error_set(error, EEXIST, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "policy ID exists. "); mtr_policy = mlx5_flow_meter_policy_find(dev, policy_id, &policy_idx); if (mtr_policy) return -rte_mtr_error_set(error, EEXIST, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "policy ID exists. "); ret = mlx5_flow_validate_mtr_acts(dev, policy->actions, &attr, &is_rss, &domain_bitmap, &is_def_policy, error); if (ret) return ret; if (!domain_bitmap) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_POLICY, NULL, "fail to find policy domain."); if (is_def_policy) { if (priv->sh->mtrmng->def_policy_id != MLX5_INVALID_POLICY_ID) return -rte_mtr_error_set(error, EEXIST, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "a policy with similar actions " "is already configured"); if (mlx5_flow_create_def_policy(dev)) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_POLICY, NULL, "fail to create non-terminated policy."); priv->sh->mtrmng->def_policy_id = policy_id; return 0; } if (!priv->sh->meter_aso_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_POLICY, NULL, "no ASO capability to support the policy "); for (i = 0; i < MLX5_MTR_DOMAIN_MAX; i++) { if (!(domain_bitmap & (1 << i))) continue; if (is_rss) { policy_size += sizeof(struct mlx5_flow_meter_sub_policy *) * MLX5_MTR_RSS_MAX_SUB_POLICY; break; } policy_size += sizeof(struct mlx5_flow_meter_sub_policy *); } mtr_policy = mlx5_malloc(MLX5_MEM_ZERO, policy_size, RTE_CACHE_LINE_SIZE, SOCKET_ID_ANY); if (!mtr_policy) return -rte_mtr_error_set(error, ENOMEM, RTE_MTR_ERROR_TYPE_METER_POLICY, NULL, "Memory alloc failed for meter policy."); policy_size = sizeof(struct mlx5_flow_meter_policy); for (i = 0; i < MLX5_MTR_DOMAIN_MAX; i++) { if (!(domain_bitmap & (1 << i))) continue; if (i == MLX5_MTR_DOMAIN_INGRESS) mtr_policy->ingress = 1; if (i == MLX5_MTR_DOMAIN_EGRESS) mtr_policy->egress = 1; if (i == MLX5_MTR_DOMAIN_TRANSFER) mtr_policy->transfer = 1; sub_policy = mlx5_ipool_zmalloc (priv->sh->ipool[MLX5_IPOOL_MTR_POLICY], &sub_policy_idx); if (!sub_policy) goto policy_add_err; if (sub_policy_idx > MLX5_MAX_SUB_POLICY_TBL_NUM) goto policy_add_err; sub_policy->idx = sub_policy_idx; sub_policy->main_policy = mtr_policy; if (!policy_idx) { policy_idx = sub_policy_idx; sub_policy->main_policy_id = 1; } mtr_policy->sub_policys[i] = (struct mlx5_flow_meter_sub_policy **) ((uint8_t *)mtr_policy + policy_size); mtr_policy->sub_policys[i][0] = sub_policy; sub_policy_num = (mtr_policy->sub_policy_num >> (MLX5_MTR_SUB_POLICY_NUM_SHIFT * i)) & MLX5_MTR_SUB_POLICY_NUM_MASK; sub_policy_num++; mtr_policy->sub_policy_num &= ~(MLX5_MTR_SUB_POLICY_NUM_MASK << (MLX5_MTR_SUB_POLICY_NUM_SHIFT * i)); mtr_policy->sub_policy_num |= (sub_policy_num & MLX5_MTR_SUB_POLICY_NUM_MASK) << (MLX5_MTR_SUB_POLICY_NUM_SHIFT * i); if (is_rss) { mtr_policy->is_rss = 1; break; } policy_size += sizeof(struct mlx5_flow_meter_sub_policy *); } rte_spinlock_init(&mtr_policy->sl); ret = mlx5_flow_create_mtr_acts(dev, mtr_policy, policy->actions, error); if (ret) goto policy_add_err; if (!is_rss && !mtr_policy->is_queue) { /* Create policy rules in HW. */ ret = mlx5_flow_create_policy_rules(dev, mtr_policy); if (ret) goto policy_add_err; } data.dword = policy_idx; if (!priv->sh->mtrmng->policy_idx_tbl) { priv->sh->mtrmng->policy_idx_tbl = mlx5_l3t_create(MLX5_L3T_TYPE_DWORD); if (!priv->sh->mtrmng->policy_idx_tbl) goto policy_add_err; } if (mlx5_l3t_set_entry(priv->sh->mtrmng->policy_idx_tbl, policy_id, &data)) goto policy_add_err; return 0; policy_add_err: if (mtr_policy) { ret = __mlx5_flow_meter_policy_delete(dev, policy_id, mtr_policy, error, false); mlx5_free(mtr_policy); if (ret) return ret; } return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Failed to create devx policy."); } /** * Callback to delete MTR policy. * * @param[in] dev * Pointer to Ethernet device. * @param[in] policy_id * Meter policy id. * @param[out] error * Pointer to the error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_policy_delete(struct rte_eth_dev *dev, uint32_t policy_id, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_policy *mtr_policy; uint32_t policy_idx; int ret; if (policy_id == priv->sh->mtrmng->def_policy_id) { if (priv->sh->mtrmng->def_policy_ref_cnt > 0) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "Meter policy object is being used."); priv->sh->mtrmng->def_policy_id = MLX5_INVALID_POLICY_ID; return 0; } mtr_policy = mlx5_flow_meter_policy_find(dev, policy_id, &policy_idx); if (!mtr_policy) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "Meter policy id is invalid. "); ret = __mlx5_flow_meter_policy_delete(dev, policy_id, mtr_policy, error, true); if (ret) return ret; mlx5_free(mtr_policy); return 0; } /** * Check meter validation. * * @param[in] priv * Pointer to mlx5 private data structure. * @param[in] meter_id * Meter id. * @param[in] params * Pointer to rte meter parameters. * @param[out] error * Pointer to rte meter error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_validate(struct mlx5_priv *priv, uint32_t meter_id, struct rte_mtr_params *params, struct rte_mtr_error *error) { /* Meter must use global drop action. */ if (!priv->sh->dr_drop_action) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL, "No drop action ready for meter."); /* Meter params must not be NULL. */ if (params == NULL) return -rte_mtr_error_set(error, EINVAL, RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL, "Meter object params null."); /* Previous meter color is not supported. */ if (params->use_prev_mtr_color) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL, "Previous meter color " "not supported."); if (params->meter_policy_id == MLX5_INVALID_POLICY_ID) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "Meter policy id not valid."); /* Validate meter id. */ if (mlx5_flow_meter_find(priv, meter_id, NULL)) return -rte_mtr_error_set(error, EEXIST, RTE_MTR_ERROR_TYPE_MTR_ID, NULL, "Meter object already exists."); return 0; } /** * Modify the flow meter action. * * @param[in] priv * Pointer to mlx5 private data structure. * @param[in] fm * Pointer to flow meter to be modified. * @param[in] srtcm * Pointer to meter srtcm description parameter. * @param[in] modify_bits * The bit in srtcm to be updated. * @param[in] active_state * The state to be updated. * @return * 0 on success, o negative value otherwise. */ static int mlx5_flow_meter_action_modify(struct mlx5_priv *priv, struct mlx5_flow_meter_info *fm, const struct mlx5_flow_meter_srtcm_rfc2697_prm *srtcm, uint64_t modify_bits, uint32_t active_state, uint32_t is_enable) { #ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER uint32_t in[MLX5_ST_SZ_DW(flow_meter_parameters)] = { 0 }; uint32_t *attr; struct mlx5dv_dr_flow_meter_attr mod_attr = { 0 }; int ret; struct mlx5_aso_mtr *aso_mtr = NULL; uint32_t cbs_cir, ebs_eir, val; if (priv->sh->meter_aso_en) { fm->is_enable = !!is_enable; aso_mtr = container_of(fm, struct mlx5_aso_mtr, fm); ret = mlx5_aso_meter_update_by_wqe(priv->sh, aso_mtr); if (ret) return ret; ret = mlx5_aso_mtr_wait(priv->sh, aso_mtr); if (ret) return ret; } else { /* Fill command parameters. */ mod_attr.reg_c_index = priv->mtr_color_reg - REG_C_0; mod_attr.flow_meter_parameter = in; mod_attr.flow_meter_parameter_sz = MLX5_ST_SZ_BYTES(flow_meter_parameters); if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE) mod_attr.active = !!active_state; else mod_attr.active = 0; attr = in; cbs_cir = rte_be_to_cpu_32(srtcm->cbs_cir); ebs_eir = rte_be_to_cpu_32(srtcm->ebs_eir); if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS) { val = (cbs_cir >> ASO_DSEG_CBS_EXP_OFFSET) & ASO_DSEG_EXP_MASK; MLX5_SET(flow_meter_parameters, attr, cbs_exponent, val); val = (cbs_cir >> ASO_DSEG_CBS_MAN_OFFSET) & ASO_DSEG_MAN_MASK; MLX5_SET(flow_meter_parameters, attr, cbs_mantissa, val); } if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR) { val = (cbs_cir >> ASO_DSEG_CIR_EXP_OFFSET) & ASO_DSEG_EXP_MASK; MLX5_SET(flow_meter_parameters, attr, cir_exponent, val); val = cbs_cir & ASO_DSEG_MAN_MASK; MLX5_SET(flow_meter_parameters, attr, cir_mantissa, val); } if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_EBS) { val = (ebs_eir >> ASO_DSEG_EBS_EXP_OFFSET) & ASO_DSEG_EXP_MASK; MLX5_SET(flow_meter_parameters, attr, ebs_exponent, val); val = (ebs_eir >> ASO_DSEG_EBS_MAN_OFFSET) & ASO_DSEG_MAN_MASK; MLX5_SET(flow_meter_parameters, attr, ebs_mantissa, val); } /* Apply modifications to meter only if it was created. */ if (fm->meter_action) { ret = mlx5_glue->dv_modify_flow_action_meter (fm->meter_action, &mod_attr, rte_cpu_to_be_64(modify_bits)); if (ret) return ret; } /* Update succeedded modify meter parameters. */ if (modify_bits & MLX5_FLOW_METER_OBJ_MODIFY_FIELD_ACTIVE) fm->active_state = !!active_state; } return 0; #else (void)priv; (void)fm; (void)srtcm; (void)modify_bits; (void)active_state; (void)is_enable; return -ENOTSUP; #endif } static int mlx5_flow_meter_stats_enable_update(struct rte_eth_dev *dev, struct mlx5_flow_meter_info *fm, uint64_t stats_mask) { fm->bytes_dropped = (stats_mask & RTE_MTR_STATS_N_BYTES_DROPPED) ? 1 : 0; fm->pkts_dropped = (stats_mask & RTE_MTR_STATS_N_PKTS_DROPPED) ? 1 : 0; if (fm->bytes_dropped || fm->pkts_dropped) { if (!fm->drop_cnt) { /* Alloc policer counters. */ fm->drop_cnt = mlx5_counter_alloc(dev); if (!fm->drop_cnt) return -1; } } else { if (fm->drop_cnt) { mlx5_counter_free(dev, fm->drop_cnt); fm->drop_cnt = 0; } } return 0; } /** * Create meter rules. * * @param[in] dev * Pointer to Ethernet device. * @param[in] meter_id * Meter id. * @param[in] params * Pointer to rte meter parameters. * @param[in] shared * Meter shared with other flow or not. * @param[out] error * Pointer to rte meter error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_create(struct rte_eth_dev *dev, uint32_t meter_id, struct rte_mtr_params *params, int shared, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_legacy_flow_meters *fms = &priv->flow_meters; struct mlx5_flow_meter_profile *fmp; struct mlx5_flow_meter_info *fm; struct mlx5_legacy_flow_meter *legacy_fm; struct mlx5_flow_meter_policy *mtr_policy = NULL; struct mlx5_indexed_pool_config flow_ipool_cfg = { .size = 0, .trunk_size = 64, .need_lock = 1, .type = "mlx5_flow_mtr_flow_id_pool", }; struct mlx5_aso_mtr *aso_mtr; uint32_t mtr_idx, policy_idx; union mlx5_l3t_data data; int ret; uint8_t domain_bitmap; uint8_t mtr_id_bits; uint8_t mtr_reg_bits = priv->mtr_reg_share ? MLX5_MTR_IDLE_BITS_IN_COLOR_REG : MLX5_REG_BITS; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter is not supported"); /* Validate the parameters. */ ret = mlx5_flow_meter_validate(priv, meter_id, params, error); if (ret) return ret; /* Meter profile must exist. */ fmp = mlx5_flow_meter_profile_find(priv, params->meter_profile_id); if (fmp == NULL) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_METER_PROFILE_ID, NULL, "Meter profile id not valid."); /* Meter policy must exist. */ if (params->meter_policy_id == priv->sh->mtrmng->def_policy_id) { __atomic_add_fetch (&priv->sh->mtrmng->def_policy_ref_cnt, 1, __ATOMIC_RELAXED); domain_bitmap = MLX5_MTR_ALL_DOMAIN_BIT; if (!priv->config.dv_esw_en) domain_bitmap &= ~MLX5_MTR_DOMAIN_TRANSFER_BIT; } else { mtr_policy = mlx5_flow_meter_policy_find(dev, params->meter_policy_id, &policy_idx); if (!priv->sh->meter_aso_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Part of the policies cannot be " "supported without ASO "); if (!mtr_policy) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "Meter policy id not valid."); domain_bitmap = (mtr_policy->ingress ? MLX5_MTR_DOMAIN_INGRESS_BIT : 0) | (mtr_policy->egress ? MLX5_MTR_DOMAIN_EGRESS_BIT : 0) | (mtr_policy->transfer ? MLX5_MTR_DOMAIN_TRANSFER_BIT : 0); } /* Allocate the flow meter memory. */ if (priv->sh->meter_aso_en) { mtr_idx = mlx5_flow_mtr_alloc(dev); if (!mtr_idx) return -rte_mtr_error_set(error, ENOMEM, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Memory alloc failed for meter."); aso_mtr = mlx5_aso_meter_by_idx(priv, mtr_idx); fm = &aso_mtr->fm; } else { legacy_fm = mlx5_ipool_zmalloc (priv->sh->ipool[MLX5_IPOOL_MTR], &mtr_idx); if (legacy_fm == NULL) return -rte_mtr_error_set(error, ENOMEM, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Memory alloc failed for meter."); legacy_fm->idx = mtr_idx; fm = &legacy_fm->fm; } mtr_id_bits = MLX5_REG_BITS - __builtin_clz(mtr_idx); if ((mtr_id_bits + priv->sh->mtrmng->max_mtr_flow_bits) > mtr_reg_bits) { DRV_LOG(ERR, "Meter number exceeds max limit."); goto error; } if (mtr_id_bits > priv->sh->mtrmng->max_mtr_bits) priv->sh->mtrmng->max_mtr_bits = mtr_id_bits; /* Fill the flow meter parameters. */ fm->meter_id = meter_id; fm->policy_id = params->meter_policy_id; fm->profile = fmp; if (mlx5_flow_meter_stats_enable_update(dev, fm, params->stats_mask)) goto error; if (mlx5_flow_create_mtr_tbls(dev, fm, mtr_idx, domain_bitmap)) goto error; /* Add to the flow meter list. */ if (!priv->sh->meter_aso_en) TAILQ_INSERT_TAIL(fms, legacy_fm, next); /* Add to the flow meter list. */ fm->active_state = 1; /* Config meter starts as active. */ fm->is_enable = 1; fm->shared = !!shared; __atomic_add_fetch(&fm->profile->ref_cnt, 1, __ATOMIC_RELAXED); if (params->meter_policy_id == priv->sh->mtrmng->def_policy_id) { fm->def_policy = 1; fm->flow_ipool = mlx5_ipool_create(&flow_ipool_cfg); if (!fm->flow_ipool) goto error; } rte_spinlock_init(&fm->sl); /* If ASO meter supported, update ASO flow meter by wqe. */ if (priv->sh->meter_aso_en) { aso_mtr = container_of(fm, struct mlx5_aso_mtr, fm); ret = mlx5_aso_meter_update_by_wqe(priv->sh, aso_mtr); if (ret) goto error; if (!priv->mtr_idx_tbl) { priv->mtr_idx_tbl = mlx5_l3t_create(MLX5_L3T_TYPE_DWORD); if (!priv->mtr_idx_tbl) goto error; } data.dword = mtr_idx; if (mlx5_l3t_set_entry(priv->mtr_idx_tbl, meter_id, &data)) goto error; } if (mtr_policy) __atomic_add_fetch(&mtr_policy->ref_cnt, 1, __ATOMIC_RELAXED); return 0; error: mlx5_flow_destroy_mtr_tbls(dev, fm); /* Free policer counters. */ if (fm->drop_cnt) mlx5_counter_free(dev, fm->drop_cnt); if (priv->sh->meter_aso_en) mlx5_flow_mtr_free(dev, mtr_idx); else mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], mtr_idx); return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Failed to create devx meter."); } static int mlx5_flow_meter_params_flush(struct rte_eth_dev *dev, struct mlx5_flow_meter_info *fm, uint32_t mtr_idx) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_legacy_flow_meters *fms = &priv->flow_meters; struct mlx5_flow_meter_profile *fmp; struct mlx5_legacy_flow_meter *legacy_fm = NULL; struct mlx5_flow_meter_policy *mtr_policy; /* Meter object must not have any owner. */ MLX5_ASSERT(!fm->ref_cnt); /* Get meter profile. */ fmp = fm->profile; if (fmp == NULL) return -1; /* Update dependencies. */ __atomic_sub_fetch(&fmp->ref_cnt, 1, __ATOMIC_RELAXED); fm->profile = NULL; /* Remove from list. */ if (!priv->sh->meter_aso_en) { legacy_fm = container_of(fm, struct mlx5_legacy_flow_meter, fm); TAILQ_REMOVE(fms, legacy_fm, next); } /* Free drop counters. */ if (fm->drop_cnt) mlx5_counter_free(dev, fm->drop_cnt); /* Free meter flow table. */ if (fm->flow_ipool) { mlx5_ipool_destroy(fm->flow_ipool); fm->flow_ipool = 0; } mlx5_flow_destroy_mtr_tbls(dev, fm); if (fm->def_policy) __atomic_sub_fetch(&priv->sh->mtrmng->def_policy_ref_cnt, 1, __ATOMIC_RELAXED); if (priv->sh->meter_aso_en) { if (!fm->def_policy) { mtr_policy = mlx5_flow_meter_policy_find(dev, fm->policy_id, NULL); if (mtr_policy) __atomic_sub_fetch(&mtr_policy->ref_cnt, 1, __ATOMIC_RELAXED); fm->policy_id = 0; } fm->def_policy = 0; if (mlx5_l3t_clear_entry(priv->mtr_idx_tbl, fm->meter_id)) return -1; mlx5_flow_mtr_free(dev, mtr_idx); } else { mlx5_ipool_free(priv->sh->ipool[MLX5_IPOOL_MTR], legacy_fm->idx); } return 0; } /** * Destroy meter rules. * * @param[in] dev * Pointer to Ethernet device. * @param[in] meter_id * Meter id. * @param[out] error * Pointer to rte meter error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_destroy(struct rte_eth_dev *dev, uint32_t meter_id, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_info *fm; uint32_t mtr_idx = 0; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter is not supported"); /* Meter object must exist. */ fm = mlx5_flow_meter_find(priv, meter_id, &mtr_idx); if (fm == NULL) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_MTR_ID, NULL, "Meter object id not valid."); /* Meter object must not have any owner. */ if (fm->ref_cnt > 0) return -rte_mtr_error_set(error, EBUSY, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter object is being used."); /* Destroy the meter profile. */ if (mlx5_flow_meter_params_flush(dev, fm, mtr_idx)) return -rte_mtr_error_set(error, EINVAL, RTE_MTR_ERROR_TYPE_METER_PROFILE_ID, NULL, "MTR object meter profile invalid."); return 0; } /** * Modify meter state. * * @param[in] priv * Pointer to mlx5 private data structure. * @param[in] fm * Pointer to flow meter. * @param[in] new_state * New state to update. * @param[out] error * Pointer to rte meter error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_modify_state(struct mlx5_priv *priv, struct mlx5_flow_meter_info *fm, uint32_t new_state, struct rte_mtr_error *error) { static const struct mlx5_flow_meter_srtcm_rfc2697_prm srtcm = { .cbs_cir = RTE_BE32(MLX5_IFC_FLOW_METER_DISABLE_CBS_CIR_VAL), .ebs_eir = 0, }; uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS | MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR; int ret; if (new_state == MLX5_FLOW_METER_DISABLE) ret = mlx5_flow_meter_action_modify(priv, fm, &srtcm, modify_bits, 0, 0); else ret = mlx5_flow_meter_action_modify(priv, fm, &fm->profile->srtcm_prm, modify_bits, 0, 1); if (ret) return -rte_mtr_error_set(error, -ret, RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL, new_state ? "Failed to enable meter." : "Failed to disable meter."); return 0; } /** * Callback to enable flow meter. * * @param[in] dev * Pointer to Ethernet device. * @param[in] meter_id * Meter id. * @param[out] error * Pointer to rte meter error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_enable(struct rte_eth_dev *dev, uint32_t meter_id, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_info *fm; int ret; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter is not supported"); /* Meter object must exist. */ fm = mlx5_flow_meter_find(priv, meter_id, NULL); if (fm == NULL) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_MTR_ID, NULL, "Meter not found."); if (fm->active_state == MLX5_FLOW_METER_ENABLE) return 0; ret = mlx5_flow_meter_modify_state(priv, fm, MLX5_FLOW_METER_ENABLE, error); if (!ret) fm->active_state = MLX5_FLOW_METER_ENABLE; return ret; } /** * Callback to disable flow meter. * * @param[in] dev * Pointer to Ethernet device. * @param[in] meter_id * Meter id. * @param[out] error * Pointer to rte meter error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_disable(struct rte_eth_dev *dev, uint32_t meter_id, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_info *fm; int ret; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter is not supported"); /* Meter object must exist. */ fm = mlx5_flow_meter_find(priv, meter_id, NULL); if (fm == NULL) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_MTR_ID, NULL, "Meter not found."); if (fm->active_state == MLX5_FLOW_METER_DISABLE) return 0; ret = mlx5_flow_meter_modify_state(priv, fm, MLX5_FLOW_METER_DISABLE, error); if (!ret) fm->active_state = MLX5_FLOW_METER_DISABLE; return ret; } /** * Callback to update meter profile. * * @param[in] dev * Pointer to Ethernet device. * @param[in] meter_id * Meter id. * @param[in] meter_profile_id * To be updated meter profile id. * @param[out] error * Pointer to rte meter error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_profile_update(struct rte_eth_dev *dev, uint32_t meter_id, uint32_t meter_profile_id, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_profile *fmp; struct mlx5_flow_meter_profile *old_fmp; struct mlx5_flow_meter_info *fm; uint64_t modify_bits = MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CBS | MLX5_FLOW_METER_OBJ_MODIFY_FIELD_CIR; int ret; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter is not supported"); /* Meter profile must exist. */ fmp = mlx5_flow_meter_profile_find(priv, meter_profile_id); if (fmp == NULL) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_METER_PROFILE_ID, NULL, "Meter profile not found."); /* Meter object must exist. */ fm = mlx5_flow_meter_find(priv, meter_id, NULL); if (fm == NULL) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_MTR_ID, NULL, "Meter not found."); /* MTR object already set to meter profile id. */ old_fmp = fm->profile; if (fmp == old_fmp) return 0; /* Update the profile. */ fm->profile = fmp; /* Update meter params in HW (if not disabled). */ if (fm->active_state == MLX5_FLOW_METER_DISABLE) return 0; ret = mlx5_flow_meter_action_modify(priv, fm, &fm->profile->srtcm_prm, modify_bits, fm->active_state, 1); if (ret) { fm->profile = old_fmp; return -rte_mtr_error_set(error, -ret, RTE_MTR_ERROR_TYPE_MTR_PARAMS, NULL, "Failed to update meter" " parmeters in hardware."); } old_fmp->ref_cnt--; fmp->ref_cnt++; return 0; } /** * Callback to update meter stats mask. * * @param[in] dev * Pointer to Ethernet device. * @param[in] meter_id * Meter id. * @param[in] stats_mask * To be updated stats_mask. * @param[out] error * Pointer to rte meter error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_stats_update(struct rte_eth_dev *dev, uint32_t meter_id, uint64_t stats_mask, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_info *fm; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter is not supported"); /* Meter object must exist. */ fm = mlx5_flow_meter_find(priv, meter_id, NULL); if (fm == NULL) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_MTR_ID, NULL, "Meter object id not valid."); if (mlx5_flow_meter_stats_enable_update(dev, fm, stats_mask)) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_MTR_ID, NULL, "Fail to allocate " "counter for meter."); return 0; } /** * Callback to read meter statistics. * * @param[in] dev * Pointer to Ethernet device. * @param[in] meter_id * Meter id. * @param[out] stats * Pointer to store the statistics. * @param[out] stats_mask * Pointer to store the stats_mask. * @param[in] clear * Statistic to be cleared after read or not. * @param[out] error * Pointer to rte meter error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ static int mlx5_flow_meter_stats_read(struct rte_eth_dev *dev, uint32_t meter_id, struct rte_mtr_stats *stats, uint64_t *stats_mask, int clear, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_info *fm; uint64_t pkts; uint64_t bytes; int ret = 0; if (!priv->mtr_en) return -rte_mtr_error_set(error, ENOTSUP, RTE_MTR_ERROR_TYPE_UNSPECIFIED, NULL, "Meter is not supported"); /* Meter object must exist. */ fm = mlx5_flow_meter_find(priv, meter_id, NULL); if (fm == NULL) return -rte_mtr_error_set(error, ENOENT, RTE_MTR_ERROR_TYPE_MTR_ID, NULL, "Meter object id not valid."); *stats_mask = 0; if (fm->bytes_dropped) *stats_mask |= RTE_MTR_STATS_N_BYTES_DROPPED; if (fm->pkts_dropped) *stats_mask |= RTE_MTR_STATS_N_PKTS_DROPPED; memset(stats, 0, sizeof(*stats)); if (fm->drop_cnt) { ret = mlx5_counter_query(dev, fm->drop_cnt, clear, &pkts, &bytes); if (ret) goto error; /* If need to read the packets, set it. */ if (fm->pkts_dropped) stats->n_pkts_dropped = pkts; /* If need to read the bytes, set it. */ if (fm->bytes_dropped) stats->n_bytes_dropped = bytes; } return 0; error: return -rte_mtr_error_set(error, ret, RTE_MTR_ERROR_TYPE_STATS, NULL, "Failed to read meter drop counters."); } static const struct rte_mtr_ops mlx5_flow_mtr_ops = { .capabilities_get = mlx5_flow_mtr_cap_get, .meter_profile_add = mlx5_flow_meter_profile_add, .meter_profile_delete = mlx5_flow_meter_profile_delete, .meter_policy_validate = mlx5_flow_meter_policy_validate, .meter_policy_add = mlx5_flow_meter_policy_add, .meter_policy_delete = mlx5_flow_meter_policy_delete, .create = mlx5_flow_meter_create, .destroy = mlx5_flow_meter_destroy, .meter_enable = mlx5_flow_meter_enable, .meter_disable = mlx5_flow_meter_disable, .meter_profile_update = mlx5_flow_meter_profile_update, .meter_dscp_table_update = NULL, .stats_update = mlx5_flow_meter_stats_update, .stats_read = mlx5_flow_meter_stats_read, }; /** * Get meter operations. * * @param dev * Pointer to Ethernet device structure. * @param arg * Pointer to set the mtr operations. * * @return * Always 0. */ int mlx5_flow_meter_ops_get(struct rte_eth_dev *dev __rte_unused, void *arg) { *(const struct rte_mtr_ops **)arg = &mlx5_flow_mtr_ops; return 0; } /** * Find meter by id. * * @param priv * Pointer to mlx5_priv. * @param meter_id * Meter id. * @param mtr_idx * Pointer to Meter index. * * @return * Pointer to the meter info found on success, NULL otherwise. */ struct mlx5_flow_meter_info * mlx5_flow_meter_find(struct mlx5_priv *priv, uint32_t meter_id, uint32_t *mtr_idx) { struct mlx5_legacy_flow_meter *legacy_fm; struct mlx5_legacy_flow_meters *fms = &priv->flow_meters; struct mlx5_aso_mtr *aso_mtr; struct mlx5_aso_mtr_pools_mng *pools_mng = &priv->sh->mtrmng->pools_mng; union mlx5_l3t_data data; if (priv->sh->meter_aso_en) { rte_spinlock_lock(&pools_mng->mtrsl); if (!pools_mng->n_valid || !priv->mtr_idx_tbl) { rte_spinlock_unlock(&pools_mng->mtrsl); return NULL; } if (mlx5_l3t_get_entry(priv->mtr_idx_tbl, meter_id, &data) || !data.dword) { rte_spinlock_unlock(&pools_mng->mtrsl); return NULL; } if (mtr_idx) *mtr_idx = data.dword; aso_mtr = mlx5_aso_meter_by_idx(priv, data.dword); /* Remove reference taken by the mlx5_l3t_get_entry. */ mlx5_l3t_clear_entry(priv->mtr_idx_tbl, meter_id); rte_spinlock_unlock(&pools_mng->mtrsl); if (!aso_mtr || aso_mtr->state == ASO_METER_FREE) return NULL; return &aso_mtr->fm; } TAILQ_FOREACH(legacy_fm, fms, next) if (meter_id == legacy_fm->fm.meter_id) { if (mtr_idx) *mtr_idx = legacy_fm->idx; return &legacy_fm->fm; } return NULL; } /** * Find meter by index. * * @param priv * Pointer to mlx5_priv. * @param idx * Meter index. * * @return * Pointer to the meter info found on success, NULL otherwise. */ struct mlx5_flow_meter_info * flow_dv_meter_find_by_idx(struct mlx5_priv *priv, uint32_t idx) { struct mlx5_aso_mtr *aso_mtr; if (priv->sh->meter_aso_en) { aso_mtr = mlx5_aso_meter_by_idx(priv, idx); if (!aso_mtr) return NULL; return &aso_mtr->fm; } else { return mlx5_ipool_get(priv->sh->ipool[MLX5_IPOOL_MTR], idx); } } /** * Attach meter to flow. * Unidirectional Meter creation can only be done * when flow direction is known, i.e. when calling meter_attach. * * @param [in] priv * Pointer to mlx5 private data. * @param[in] fm * Pointer to flow meter. * @param [in] attr * Pointer to flow attributes. * @param [out] error * Pointer to error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ int mlx5_flow_meter_attach(struct mlx5_priv *priv, struct mlx5_flow_meter_info *fm, const struct rte_flow_attr *attr, struct rte_flow_error *error) { int ret = 0; if (priv->sh->meter_aso_en) { struct mlx5_aso_mtr *aso_mtr; aso_mtr = container_of(fm, struct mlx5_aso_mtr, fm); if (mlx5_aso_mtr_wait(priv->sh, aso_mtr)) { return rte_flow_error_set(error, ENOENT, RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL, "Timeout in meter configuration"); } rte_spinlock_lock(&fm->sl); if (fm->shared || !fm->ref_cnt) { fm->ref_cnt++; } else { rte_flow_error_set(error, EINVAL, RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL, "Meter cannot be shared"); ret = -1; } rte_spinlock_unlock(&fm->sl); } else { rte_spinlock_lock(&fm->sl); if (fm->meter_action) { if (fm->shared && attr->transfer == fm->transfer && attr->ingress == fm->ingress && attr->egress == fm->egress) { fm->ref_cnt++; } else { rte_flow_error_set(error, EINVAL, RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL, fm->shared ? "Meter attr not match." : "Meter cannot be shared."); ret = -1; } } else { fm->ingress = attr->ingress; fm->egress = attr->egress; fm->transfer = attr->transfer; fm->ref_cnt = 1; /* This also creates the meter object. */ fm->meter_action = mlx5_flow_meter_action_create(priv, fm); if (!fm->meter_action) { fm->ref_cnt = 0; fm->ingress = 0; fm->egress = 0; fm->transfer = 0; rte_flow_error_set(error, EINVAL, RTE_FLOW_ERROR_TYPE_UNSPECIFIED, NULL, "Meter action create failed."); ret = -1; } } rte_spinlock_unlock(&fm->sl); } return ret ? -rte_errno : 0; } /** * Detach meter from flow. * * @param [in] priv * Pointer to mlx5 private data. * @param [in] fm * Pointer to flow meter. */ void mlx5_flow_meter_detach(struct mlx5_priv *priv, struct mlx5_flow_meter_info *fm) { #ifdef HAVE_MLX5_DR_CREATE_ACTION_FLOW_METER rte_spinlock_lock(&fm->sl); MLX5_ASSERT(fm->ref_cnt); if (--fm->ref_cnt == 0 && !priv->sh->meter_aso_en) { mlx5_glue->destroy_flow_action(fm->meter_action); fm->meter_action = NULL; fm->ingress = 0; fm->egress = 0; fm->transfer = 0; } rte_spinlock_unlock(&fm->sl); #else (void)priv; (void)fm; #endif } /** * Flush meter with Rx queue configuration. * * @param[in] dev * Pointer to Ethernet device. */ void mlx5_flow_meter_rxq_flush(struct rte_eth_dev *dev) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_flow_meter_sub_policy *sub_policy; struct mlx5_flow_meter_policy *mtr_policy; void *entry; uint32_t i, policy_idx; if (!priv->mtr_en) return; if (priv->sh->mtrmng->policy_idx_tbl && priv->sh->refcnt == 1) { MLX5_L3T_FOREACH(priv->sh->mtrmng->policy_idx_tbl, i, entry) { policy_idx = *(uint32_t *)entry; sub_policy = mlx5_ipool_get (priv->sh->ipool[MLX5_IPOOL_MTR_POLICY], policy_idx); if (!sub_policy || !sub_policy->main_policy) continue; mtr_policy = sub_policy->main_policy; if (mtr_policy->is_queue || mtr_policy->is_rss) mlx5_flow_destroy_sub_policy_with_rxq(dev, mtr_policy); } } } /** * Flush meter configuration. * * @param[in] dev * Pointer to Ethernet device. * @param[out] error * Pointer to rte meter error structure. * * @return * 0 on success, a negative errno value otherwise and rte_errno is set. */ int mlx5_flow_meter_flush(struct rte_eth_dev *dev, struct rte_mtr_error *error) { struct mlx5_priv *priv = dev->data->dev_private; struct mlx5_legacy_flow_meters *fms = &priv->flow_meters; struct mlx5_mtr_profiles *fmps = &priv->flow_meter_profiles; struct mlx5_flow_meter_profile *fmp; struct mlx5_legacy_flow_meter *legacy_fm; struct mlx5_flow_meter_info *fm; struct mlx5_flow_meter_sub_policy *sub_policy; void *tmp; uint32_t i, mtr_idx, policy_idx; void *entry; struct mlx5_aso_mtr *aso_mtr; if (!priv->mtr_en) return 0; if (priv->sh->meter_aso_en) { if (priv->mtr_idx_tbl) { MLX5_L3T_FOREACH(priv->mtr_idx_tbl, i, entry) { mtr_idx = *(uint32_t *)entry; if (mtr_idx) { aso_mtr = mlx5_aso_meter_by_idx(priv, mtr_idx); fm = &aso_mtr->fm; (void)mlx5_flow_meter_params_flush(dev, fm, mtr_idx); } } mlx5_l3t_destroy(priv->mtr_idx_tbl); priv->mtr_idx_tbl = NULL; } } else { TAILQ_FOREACH_SAFE(legacy_fm, fms, next, tmp) { fm = &legacy_fm->fm; if (mlx5_flow_meter_params_flush(dev, fm, 0)) return -rte_mtr_error_set(error, EINVAL, RTE_MTR_ERROR_TYPE_METER_PROFILE_ID, NULL, "MTR object meter profile invalid."); } } if (priv->sh->mtrmng->policy_idx_tbl && priv->sh->refcnt == 1) { MLX5_L3T_FOREACH(priv->sh->mtrmng->policy_idx_tbl, i, entry) { policy_idx = *(uint32_t *)entry; sub_policy = mlx5_ipool_get (priv->sh->ipool[MLX5_IPOOL_MTR_POLICY], policy_idx); if (!sub_policy) return -rte_mtr_error_set(error, EINVAL, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "MTR object " "meter policy invalid."); if (__mlx5_flow_meter_policy_delete(dev, i, sub_policy->main_policy, error, true)) return -rte_mtr_error_set(error, EINVAL, RTE_MTR_ERROR_TYPE_METER_POLICY_ID, NULL, "MTR object " "meter policy invalid."); mlx5_free(sub_policy->main_policy); } mlx5_l3t_destroy(priv->sh->mtrmng->policy_idx_tbl); priv->sh->mtrmng->policy_idx_tbl = NULL; } TAILQ_FOREACH_SAFE(fmp, fmps, next, tmp) { /* Check unused. */ MLX5_ASSERT(!fmp->ref_cnt); /* Remove from list. */ TAILQ_REMOVE(&priv->flow_meter_profiles, fmp, next); mlx5_free(fmp); } /* Delete default policy table. */ mlx5_flow_destroy_def_policy(dev); if (priv->sh->refcnt == 1) mlx5_flow_destroy_mtr_drop_tbls(dev); return 0; }