.. SPDX-License-Identifier: BSD-3-Clause
|
|
Copyright(c) 2019-2021 Xilinx, Inc.
|
|
Copyright(c) 2016-2019 Solarflare Communications Inc.
|
|
|
|
This software was jointly developed between OKTET Labs (under contract
|
|
for Solarflare) and Solarflare Communications, Inc.
|
|
|
|
Solarflare libefx-based Poll Mode Driver
|
|
========================================
|
|
|
|
The SFC EFX PMD (**librte_net_sfc_efx**) provides poll mode driver support
|
|
for **Solarflare SFN7xxx and SFN8xxx** family of 10/40 Gbps adapters,
|
|
**Solarflare XtremeScale X2xxx** family of 10/25/40/50/100 Gbps adapters and
|
|
**Alveo SN1000 SmartNICs** family of 10/25/40/50/100 Gbps adapters.
|
|
SFC EFX PMD has support for the latest Linux and FreeBSD operating systems.
|
|
|
|
More information can be found at `Solarflare Communications website
|
|
<http://solarflare.com>`_.
|
|
|
|
|
|
Features
|
|
--------
|
|
|
|
SFC EFX PMD has support for:
|
|
|
|
- Multiple transmit and receive queues
|
|
|
|
- Link state information including link status change interrupt
|
|
|
|
- IPv4/IPv6 TCP/UDP transmit checksum offload
|
|
|
|
- Inner IPv4/IPv6 TCP/UDP transmit checksum offload
|
|
|
|
- Port hardware statistics
|
|
|
|
- Extended statistics (see Solarflare Server Adapter User's Guide for
|
|
the statistics description)
|
|
|
|
- Basic flow control
|
|
|
|
- MTU update
|
|
|
|
- Jumbo frames up to 9K
|
|
|
|
- Promiscuous mode
|
|
|
|
- Allmulticast mode
|
|
|
|
- TCP segmentation offload (TSO) including VXLAN and GENEVE encapsulated
|
|
|
|
- Multicast MAC filter
|
|
|
|
- IPv4/IPv6 TCP/UDP receive checksum offload
|
|
|
|
- Inner IPv4/IPv6 TCP/UDP receive checksum offload
|
|
|
|
- Received packet type information
|
|
|
|
- Receive side scaling (RSS)
|
|
|
|
- RSS hash
|
|
|
|
- Scattered Rx DMA for packet that are larger that a single Rx descriptor
|
|
|
|
- Receive queue interrupts
|
|
|
|
- Deferred receive and transmit queue start
|
|
|
|
- Transmit VLAN insertion (if running firmware variant supports it)
|
|
|
|
- Flow API
|
|
|
|
- Loopback
|
|
|
|
- SR-IOV PF
|
|
|
|
- Port representors (see :ref: switch_representation)
|
|
|
|
|
|
Non-supported Features
|
|
----------------------
|
|
|
|
The features not yet supported include:
|
|
|
|
- Priority-based flow control
|
|
|
|
- Configurable RX CRC stripping (always stripped)
|
|
|
|
- Header split on receive
|
|
|
|
- VLAN filtering
|
|
|
|
- VLAN stripping
|
|
|
|
- LRO
|
|
|
|
|
|
Limitations
|
|
-----------
|
|
|
|
Due to requirements on receive buffer alignment and usage of the receive
|
|
buffer for the auxiliary packet information provided by the NIC up to
|
|
extra 269 (14 bytes prefix plus up to 255 bytes for end padding) bytes may be
|
|
required in the receive buffer.
|
|
It should be taken into account when mbuf pool for receive is created.
|
|
|
|
|
|
Equal stride super-buffer mode
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
When the receive queue uses equal stride super-buffer DMA mode, one HW Rx
|
|
descriptor carries many Rx buffers which contiguously follow each other
|
|
with some stride (equal to total size of rte_mbuf as mempool object).
|
|
Each Rx buffer is an independent rte_mbuf.
|
|
However dedicated mempool manager must be used when mempool for the Rx
|
|
queue is created. The manager must support dequeue of the contiguous
|
|
block of objects and provide mempool info API to get the block size.
|
|
|
|
Another limitation of a equal stride super-buffer mode, imposed by the
|
|
firmware, is that it allows for a single RSS context.
|
|
|
|
|
|
Tunnels support
|
|
---------------
|
|
|
|
NVGRE, VXLAN and GENEVE tunnels are supported on SFN8xxx and X2xxx family
|
|
adapters with full-feature firmware variant running.
|
|
**sfboot** should be used to configure NIC to run full-feature firmware variant.
|
|
See Solarflare Server Adapter User's Guide for details.
|
|
|
|
SFN8xxx and X2xxx family adapters provide either inner or outer packet classes.
|
|
If adapter firmware advertises support for tunnels then the PMD
|
|
configures the hardware to report inner classes, and outer classes are
|
|
not reported in received packets.
|
|
However, for VXLAN and GENEVE tunnels the PMD does report UDP as the
|
|
outer layer 4 packet type.
|
|
|
|
SFN8xxx and X2xxx family adapters report GENEVE packets as VXLAN.
|
|
If UDP ports are configured for only one tunnel type then it is safe to
|
|
treat VXLAN packet type indication as the corresponding UDP tunnel type.
|
|
|
|
|
|
Flow API support
|
|
----------------
|
|
|
|
Supported attributes:
|
|
|
|
- Ingress
|
|
- Transfer
|
|
|
|
Supported pattern items (***non-transfer*** rules):
|
|
|
|
- VOID
|
|
|
|
- ETH (exact match of source/destination addresses, individual/group match
|
|
of destination address, EtherType in the outer frame and exact match of
|
|
destination addresses, individual/group match of destination address in
|
|
the inner frame)
|
|
|
|
- VLAN (exact match of VID, double-tagging is supported)
|
|
|
|
- IPV4 (exact match of source/destination addresses,
|
|
IP transport protocol)
|
|
|
|
- IPV6 (exact match of source/destination addresses,
|
|
IP transport protocol)
|
|
|
|
- TCP (exact match of source/destination ports)
|
|
|
|
- UDP (exact match of source/destination ports)
|
|
|
|
- VXLAN (exact match of VXLAN network identifier)
|
|
|
|
- GENEVE (exact match of virtual network identifier, only Ethernet (0x6558)
|
|
protocol type is supported)
|
|
|
|
- NVGRE (exact match of virtual subnet ID)
|
|
|
|
Supported actions (***non-transfer*** rules):
|
|
|
|
- VOID
|
|
|
|
- QUEUE
|
|
|
|
- RSS
|
|
|
|
- DROP
|
|
|
|
- FLAG (supported only with ef10_essb Rx datapath)
|
|
|
|
- MARK (supported only with ef10_essb Rx datapath)
|
|
|
|
Supported pattern items (***transfer*** rules):
|
|
|
|
- PORT_REPRESENTOR (cannot repeat; conflicts with other traffic source items)
|
|
|
|
- REPRESENTED_PORT (cannot repeat; conflicts with other traffic source items)
|
|
|
|
- PORT_ID (cannot repeat; conflicts with other traffic source items)
|
|
|
|
- ETH
|
|
|
|
- VLAN (double-tagging is supported)
|
|
|
|
- IPV4 (source/destination addresses, IP transport protocol,
|
|
type of service, time to live)
|
|
|
|
- IPV6 (source/destination addresses, IP transport protocol,
|
|
traffic class, hop limit)
|
|
|
|
- TCP (source/destination ports, TCP header length + TCP flags)
|
|
|
|
- UDP (source/destination ports)
|
|
|
|
- VXLAN (exact match of VXLAN network identifier)
|
|
|
|
- GENEVE (exact match of virtual network identifier)
|
|
|
|
- NVGRE (exact match of virtual subnet ID)
|
|
|
|
Supported actions (***transfer*** rules):
|
|
|
|
- OF_POP_VLAN
|
|
|
|
- OF_PUSH_VLAN
|
|
|
|
- OF_VLAN_SET_VID
|
|
|
|
- OF_VLAN_SET_PCP
|
|
|
|
- SET_MAC_DST
|
|
|
|
- SET_MAC_SRC
|
|
|
|
- OF_DEC_NW_TTL
|
|
|
|
- DEC_TTL
|
|
|
|
- VXLAN_DECAP
|
|
|
|
- VXLAN_ENCAP
|
|
|
|
- FLAG
|
|
|
|
- MARK
|
|
|
|
- PF
|
|
|
|
- VF
|
|
|
|
- PORT_REPRESENTOR
|
|
|
|
- REPRESENTED_PORT
|
|
|
|
- PORT_ID
|
|
|
|
- COUNT
|
|
|
|
- DROP
|
|
|
|
Validating flow rules depends on the firmware variant.
|
|
|
|
The :ref:`flow_isolated_mode` is supported.
|
|
|
|
The implementation is natively thread-safe.
|
|
|
|
Ethernet destination individual/group match
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Ethernet item supports I/G matching, if only the corresponding bit is set
|
|
in the mask of destination address. If destination address in the spec is
|
|
multicast, it matches all multicast (and broadcast) packets, otherwise it
|
|
matches unicast packets that are not filtered by other flow rules.
|
|
|
|
Exceptions to flow rules
|
|
~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
There is a list of exceptional flow rule patterns which will not be
|
|
accepted by the PMD. A pattern will be rejected if at least one of the
|
|
conditions is met:
|
|
|
|
- Filtering by IPv4 or IPv6 EtherType without pattern items of internet
|
|
layer and above.
|
|
|
|
- The last item is IPV4 or IPV6, and it's empty.
|
|
|
|
- Filtering by TCP or UDP IP transport protocol without pattern items of
|
|
transport layer and above.
|
|
|
|
- The last item is TCP or UDP, and it's empty.
|
|
|
|
|
|
Supported NICs
|
|
--------------
|
|
|
|
- Xilinx Adapters:
|
|
|
|
- Alveo SN1022 SmartNIC
|
|
|
|
- Solarflare XtremeScale Adapters:
|
|
|
|
- Solarflare X2522 Dual Port SFP28 10/25GbE Adapter
|
|
|
|
- Solarflare X2541 Single Port QSFP28 10/25G/100G Adapter
|
|
|
|
- Solarflare X2542 Dual Port QSFP28 10/25G/100G Adapter
|
|
|
|
- Solarflare Flareon [Ultra] Server Adapters:
|
|
|
|
- Solarflare SFN8522 Dual Port SFP+ Server Adapter
|
|
|
|
- Solarflare SFN8522M Dual Port SFP+ Server Adapter
|
|
|
|
- Solarflare SFN8042 Dual Port QSFP+ Server Adapter
|
|
|
|
- Solarflare SFN8542 Dual Port QSFP+ Server Adapter
|
|
|
|
- Solarflare SFN8722 Dual Port SFP+ OCP Server Adapter
|
|
|
|
- Solarflare SFN7002F Dual Port SFP+ Server Adapter
|
|
|
|
- Solarflare SFN7004F Quad Port SFP+ Server Adapter
|
|
|
|
- Solarflare SFN7042Q Dual Port QSFP+ Server Adapter
|
|
|
|
- Solarflare SFN7122F Dual Port SFP+ Server Adapter
|
|
|
|
- Solarflare SFN7124F Quad Port SFP+ Server Adapter
|
|
|
|
- Solarflare SFN7142Q Dual Port QSFP+ Server Adapter
|
|
|
|
- Solarflare SFN7322F Precision Time Synchronization Server Adapter
|
|
|
|
|
|
Prerequisites
|
|
-------------
|
|
|
|
- Requires firmware version:
|
|
|
|
- SFN7xxx: **4.7.1.1001** or higher
|
|
|
|
- SFN8xxx: **6.0.2.1004** or higher
|
|
|
|
Visit `Solarflare Support Downloads <https://support.solarflare.com>`_ to get
|
|
Solarflare Utilities (either Linux or FreeBSD) with the latest firmware.
|
|
Follow instructions from Solarflare Server Adapter User's Guide to
|
|
update firmware and configure the adapter.
|
|
|
|
|
|
Pre-Installation Configuration
|
|
------------------------------
|
|
|
|
|
|
Build Options
|
|
~~~~~~~~~~~~~
|
|
|
|
The following build-time options may be enabled on build time using
|
|
``-Dc_args=`` meson argument (e.g. ``-Dc_args=-DRTE_LIBRTE_SFC_EFX_DEBUG``).
|
|
|
|
Please note that enabling debugging options may affect system performance.
|
|
|
|
- ``RTE_LIBRTE_SFC_EFX_DEBUG`` (undefined by default)
|
|
|
|
Enable compilation of the extra run-time consistency checks.
|
|
|
|
|
|
Per-Device Parameters
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The following per-device parameters can be passed via EAL PCI device
|
|
allow option like "-a 02:00.0,arg1=value1,...".
|
|
|
|
Case-insensitive 1/y/yes/on or 0/n/no/off may be used to specify
|
|
boolean parameters value.
|
|
|
|
- ``class`` [net|vdpa] (default **net**)
|
|
|
|
Choose the mode of operation of ef100 device.
|
|
**net** device will work as network device and will be probed by net/sfc driver.
|
|
**vdpa** device will work as vdpa device and will be probed by vdpa/sfc driver.
|
|
If this parameter is not specified then ef100 device will operate as
|
|
network device.
|
|
|
|
- ``switch_mode`` [legacy|switchdev] (see below for default)
|
|
|
|
In legacy mode, NIC firmware provides Ethernet virtual bridging (EVB) API
|
|
to configure switching inside NIC to deliver traffic to physical (PF) and
|
|
virtual (VF) PCI functions. PF driver is responsible to build the
|
|
infrastructure for VFs, and traffic goes to/from VF by default in accordance
|
|
with MAC address assigned, permissions and filters installed by VF drivers.
|
|
In switchdev mode VF traffic goes via port representor (if any) on PF, and
|
|
software virtual switch (for example, Open vSwitch) makes the decision.
|
|
Software virtual switch may install MAE rules to pass established traffic
|
|
flows via hardware and offload software datapath as the result.
|
|
Default is legacy, unless representors are specified, in which case switchdev
|
|
is chosen.
|
|
|
|
- ``representor`` parameter [list]
|
|
|
|
Instantiate port representor Ethernet devices for specified Virtual
|
|
Functions list.
|
|
|
|
It is a standard parameter whose format is described in
|
|
:ref:`ethernet_device_standard_device_arguments`.
|
|
|
|
- ``rx_datapath`` [auto|efx|ef10|ef10_essb] (default **auto**)
|
|
|
|
Choose receive datapath implementation.
|
|
**auto** allows the driver itself to make a choice based on firmware
|
|
features available and required by the datapath implementation.
|
|
**efx** chooses libefx-based datapath which supports Rx scatter.
|
|
Supported for SFN7xxx, SFN8xxx and X2xxx family adapters only.
|
|
**ef10** chooses EF10 (SFN7xxx, SFN8xxx, X2xxx) native datapath which is
|
|
more efficient than libefx-based and provides richer packet type
|
|
classification.
|
|
**ef10_essb** chooses SFNX2xxx equal stride super-buffer datapath
|
|
which may be used on DPDK firmware variant only
|
|
(see notes about its limitations above).
|
|
**ef100** chooses EF100 native datapath which is the only supported
|
|
Rx datapath for EF100 architecture based NICs.
|
|
|
|
- ``tx_datapath`` [auto|efx|ef10|ef10_simple|ef100] (default **auto**)
|
|
|
|
Choose transmit datapath implementation.
|
|
**auto** allows the driver itself to make a choice based on firmware
|
|
features available and required by the datapath implementation.
|
|
**efx** chooses libefx-based datapath which supports VLAN insertion
|
|
(full-feature firmware variant only), TSO and multi-segment mbufs.
|
|
Mbuf segments may come from different mempools, and mbuf reference
|
|
counters are treated responsibly.
|
|
Supported for SFN7xxx, SFN8xxx and X2xxx family adapters only.
|
|
**ef10** chooses EF10 (SFN7xxx, SFN8xxx, X2xxx) native datapath which is
|
|
more efficient than libefx-based but has no VLAN insertion support yet.
|
|
Mbuf segments may come from different mempools, and mbuf reference
|
|
counters are treated responsibly.
|
|
**ef10_simple** chooses EF10 (SFN7xxx, SFN8xxx, X2xxx) native datapath which
|
|
is even more faster then **ef10** but does not support multi-segment
|
|
mbufs, disallows multiple mempools and neglects mbuf reference counters.
|
|
**ef100** chooses EF100 native datapath which supports multi-segment
|
|
mbufs, VLAN insertion, inner/outer IPv4 and TCP/UDP checksum and TCP
|
|
segmentation offloads including VXLAN and GENEVE IPv4/IPv6 tunnels.
|
|
|
|
- ``perf_profile`` [auto|throughput|low-latency] (default **throughput**)
|
|
|
|
Choose hardware tuning to be optimized for either throughput or
|
|
low-latency.
|
|
**auto** allows NIC firmware to make a choice based on
|
|
installed licenses and firmware variant configured using **sfboot**.
|
|
|
|
- ``stats_update_period_ms`` [long] (default **1000**)
|
|
|
|
Adjust period in milliseconds to update port hardware statistics.
|
|
The accepted range is 0 to 65535. The value of **0** may be used
|
|
to disable periodic statistics update. One should note that it's
|
|
only possible to set an arbitrary value on SFN8xxx and X2xxx provided that
|
|
firmware version is 6.2.1.1033 or higher, otherwise any positive
|
|
value will select a fixed update period of **1000** milliseconds
|
|
|
|
- ``fw_variant`` [dont-care|full-feature|ultra-low-latency|
|
|
capture-packed-stream|dpdk] (default **dont-care**)
|
|
|
|
Choose the preferred firmware variant to use.
|
|
The parameter is supported for SFN7xxX, SFN8xxx and X2xxx families only.
|
|
In order for the selected option to have an effect, the **sfboot** utility
|
|
must be configured with the **auto** firmware-variant option.
|
|
The preferred firmware variant applies to all ports on the NIC.
|
|
**dont-care** ensures that the driver can attach to an unprivileged function.
|
|
The datapath firmware type to use is controlled by the **sfboot**
|
|
utility.
|
|
**full-feature** chooses full featured firmware.
|
|
**ultra-low-latency** chooses firmware with fewer features but lower latency.
|
|
**capture-packed-stream** chooses firmware for SolarCapture packed stream
|
|
mode.
|
|
**dpdk** chooses DPDK firmware with equal stride super-buffer Rx mode
|
|
for higher Rx packet rate and packet marks support and firmware subvariant
|
|
without checksumming on transmit for higher Tx packet rate if
|
|
checksumming is not required.
|
|
|
|
- ``rxd_wait_timeout_ns`` [long] (default **200 us**)
|
|
|
|
Adjust timeout in nanoseconds to head-of-line block to wait for
|
|
Rx descriptors.
|
|
The accepted range is 0 to 400 ms.
|
|
Flow control should be enabled to make it work.
|
|
The value of **0** disables it and packets are dropped immediately.
|
|
When a packet is dropped because of no Rx descriptors,
|
|
``rx_nodesc_drop_cnt`` counter grows.
|
|
The feature is supported only by the DPDK firmware variant when equal
|
|
stride super-buffer Rx mode is used.
|
|
|
|
|
|
Dynamic Logging Parameters
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
One may leverage EAL option "--log-level" to change default levels
|
|
for the log types supported by the driver. The option is used with
|
|
an argument typically consisting of two parts separated by a colon.
|
|
|
|
Level value is the last part which takes a symbolic name (or integer).
|
|
Log type is the former part which may shell match syntax.
|
|
Depending on the choice of the expression, the given log level may
|
|
be used either for some specific log type or for a subset of types.
|
|
|
|
SFC EFX PMD provides the following log types available for control:
|
|
|
|
- ``pmd.net.sfc.driver`` (default level is **notice**)
|
|
|
|
Affects driver-wide messages unrelated to any particular devices.
|
|
|
|
- ``pmd.net.sfc.main`` (default level is **notice**)
|
|
|
|
Matches a subset of per-port log types registered during runtime.
|
|
A full name for a particular type may be obtained by appending a
|
|
dot and a PCI device identifier (``XXXX:XX:XX.X``) to the prefix.
|
|
|
|
- ``pmd.net.sfc.mcdi`` (default level is **notice**)
|
|
|
|
Extra logging of the communication with the NIC's management CPU.
|
|
The format of the log is consumed by the Solarflare netlogdecode
|
|
cross-platform tool. May be managed per-port, as explained above.
|