Shahed Shaikh 0833120f20 net/qede: fix slow path completion timeout
In 100G mode, we poll firmware slow path completion for every 1 second,
which is not enough and may result in completion timeout if
driver misses that window.

Patch "eal: set affinity for control threads" exposed this issue since
alarm callback runs in control thread context.

Fix this issue by update polling period to 100ms.

Fixes: d651ee4919cd ("eal: set affinity for control threads")
Fixes: 2af14ca79c0a ("net/qede: support 100G")
Cc: stable@dpdk.org

Signed-off-by: Shahed Shaikh <shahed.shaikh@cavium.com>
2018-05-25 17:07:40 +02:00
..