numam-dpdk/doc/guides/nics/vmxnet3.rst
John McNamara 4a22e6ee3d doc: refactor figure numbers into references
This change adds automatic figure references to the docs. The
figure numbers in the generated Html and PDF docs are now
automatically numbered based on section.

Requires Sphinx >= 1.3.1.

The patch makes the following changes.

* Changes image:: tag to figure:: and moves image caption
  to the figure.

* Adds captions to figures that didn't previously have any.

* Un-templates the |image-name| substitution definitions
  into explicit figure:: tags. They weren't used more
  than once anyway and Sphinx doesn't support them
  for figure.

* Adds a target to each image that didn't previously
  have one so that they can be cross-referenced.

* Renamed existing image target to match the image
  name for consistency.

* Replaces the Figures lists with automatic :numref:
  :ref: entries to generate automatic numbering
  and captions.

* Replaces "Figure" references with automatic :numref:
  references.

Signed-off-by: John McNamara <john.mcnamara@intel.com>
2015-05-25 15:59:36 +02:00

198 lines
8.5 KiB
ReStructuredText

.. BSD LICENSE
Copyright(c) 2010-2014 Intel Corporation. All rights reserved.
All rights reserved.
Redistribution and use in source and binary forms, with or without
modification, are permitted provided that the following conditions
are met:
* Redistributions of source code must retain the above copyright
notice, this list of conditions and the following disclaimer.
* Redistributions in binary form must reproduce the above copyright
notice, this list of conditions and the following disclaimer in
the documentation and/or other materials provided with the
distribution.
* Neither the name of Intel Corporation nor the names of its
contributors may be used to endorse or promote products derived
from this software without specific prior written permission.
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
Poll Mode Driver for Paravirtual VMXNET3 NIC
============================================
The VMXNET3 adapter is the next generation of a paravirtualized NIC, introduced by VMware* ESXi.
It is designed for performance and is not related to VMXNET or VMXENET2.
It offers all the features available in VMXNET2, and adds several new features such as,
multi-queue support (also known as Receive Side Scaling, RSS),
IPv6 offloads, and MSI/MSI-X interrupt delivery.
Because operating system vendors do not provide built-in drivers for this card,
VMware Tools must be installed to have a driver for the VMXNET3 network adapter available.
One can use the same device in a DPDK application with VMXNET3 PMD introduced in DPDK API.
Currently, the driver provides basic support for using the device in a DPDK application running on a guest OS.
Optimization is needed on the backend, that is, the VMware* ESXi vmkernel switch, to achieve optimal performance end-to-end.
In this chapter, two setups with the use of the VMXNET3 PMD are demonstrated:
#. Vmxnet3 with a native NIC connected to a vSwitch
#. Vmxnet3 chaining VMs connected to a vSwitch
VMXNET3 Implementation in the DPDK
----------------------------------
For details on the VMXNET3 device, refer to the VMXNET3 driver's vmxnet3 directory and support manual from VMware*.
For performance details, refer to the following link from VMware:
`http://www.vmware.com/pdf/vsp_4_vmxnet3_perf.pdf <http://www.vmware.com/pdf/vsp_4_vmxnet3_perf.pdf>`_
As a PMD, the VMXNET3 driver provides the packet reception and transmission callbacks, vmxnet3_recv_pkts and vmxnet3_xmit_pkts.
It does not support scattered packet reception as part of vmxnet3_recv_pkts and vmxnet3_xmit_pkts.
Also, it does not support scattered packet reception as part of the device operations supported.
The VMXNET3 PMD handles all the packet buffer memory allocation and resides in guest address space
and it is solely responsible to free that memory when not needed.
The packet buffers and features to be supported are made available to hypervisor via VMXNET3 PCI configuration space BARs.
During RX/TX, the packet buffers are exchanged by their GPAs,
and the hypervisor loads the buffers with packets in the RX case and sends packets to vSwitch in the TX case.
The VMXNET3 PMD is compiled with vmxnet3 device headers.
The interface is similar to that of the other PMDs available in the DPDK API.
The driver pre-allocates the packet buffers and loads the command ring descriptors in advance.
The hypervisor fills those packet buffers on packet arrival and write completion ring descriptors,
which are eventually pulled by the PMD.
After reception, the DPDK application frees the descriptors and loads new packet buffers for the coming packets.
The interrupts are disabled and there is no notification required.
This keeps performance up on the RX side, even though the device provides a notification feature.
In the transmit routine, the DPDK application fills packet buffer pointers in the descriptors of the command ring
and notifies the hypervisor.
In response the hypervisor takes packets and passes them to the vSwitch. It writes into the completion descriptors ring.
The rings are read by the PMD in the next transmit routine call and the buffers and descriptors are freed from memory.
Features and Limitations of VMXNET3 PMD
---------------------------------------
In release 1.6.0, the VMXNET3 PMD provides the basic functionality of packet reception and transmission.
There are several options available for filtering packets at VMXNET3 device level including:
#. MAC Address based filtering:
* Unicast, Broadcast, All Multicast modes - SUPPORTED BY DEFAULT
* Multicast with Multicast Filter table - NOT SUPPORTED
* Promiscuous mode - SUPPORTED
* RSS based load balancing between queues - SUPPORTED
#. VLAN filtering:
* VLAN tag based filtering without load balancing - SUPPORTED
.. note::
* Release 1.6.0 does not support separate headers and body receive cmd_ring and hence,
multiple segment buffers are not supported.
Only cmd_ring_0 is used for packet buffers, one for each descriptor.
* Receive and transmit of scattered packets is not supported.
* Multicast with Multicast Filter table is not supported.
Prerequisites
-------------
The following prerequisites apply:
* Before starting a VM, a VMXNET3 interface to a VM through VMware vSphere Client must be assigned.
This is shown in the figure below.
.. _figure_vmxnet3_int:
.. figure:: img/vmxnet3_int.*
Assigning a VMXNET3 interface to a VM using VMware vSphere Client
.. note::
Depending on the Virtual Machine type, the VMware vSphere Client shows Ethernet adaptors while adding an Ethernet device.
Ensure that the VM type used offers a VMXNET3 device. Refer to the VMware documentation for a listed of VMs.
.. note::
Follow the *DPDK Getting Started Guide* to setup the basic DPDK environment.
.. note::
Follow the *DPDK Sample Application's User Guide*, L2 Forwarding/L3 Forwarding and
TestPMD for instructions on how to run a DPDK application using an assigned VMXNET3 device.
VMXNET3 with a Native NIC Connected to a vSwitch
------------------------------------------------
This section describes an example setup for Phy-vSwitch-VM-Phy communication.
.. _figure_vswitch_vm:
.. figure:: img/vswitch_vm.*
VMXNET3 with a Native NIC Connected to a vSwitch
.. note::
Other instructions on preparing to use DPDK such as, hugepage enabling, uio port binding are not listed here.
Please refer to *DPDK Getting Started Guide and DPDK Sample Application's User Guide* for detailed instructions.
The packet reception and transmission flow path is::
Packet generator -> 82576
-> VMware ESXi vSwitch
-> VMXNET3 device
-> Guest VM VMXNET3 port 0 rx burst
-> Guest VM 82599 VF port 0 tx burst
-> 82599 VF
-> Packet generator
VMXNET3 Chaining VMs Connected to a vSwitch
-------------------------------------------
The following figure shows an example VM-to-VM communication over a Phy-VM-vSwitch-VM-Phy communication channel.
.. _figure_vm_vm_comms:
.. figure:: img/vm_vm_comms.*
VMXNET3 Chaining VMs Connected to a vSwitch
.. note::
When using the L2 Forwarding or L3 Forwarding applications,
a destination MAC address needs to be written in packets to hit the other VM's VMXNET3 interface.
In this example, the packet flow path is::
Packet generator -> 82599 VF
-> Guest VM 82599 port 0 rx burst
-> Guest VM VMXNET3 port 1 tx burst
-> VMXNET3 device
-> VMware ESXi vSwitch
-> VMXNET3 device
-> Guest VM VMXNET3 port 0 rx burst
-> Guest VM 82599 VF port 1 tx burst
-> 82599 VF
-> Packet generator