35b09d76f8
The coremask option in DPDK is difficult to use and we should be promoting the use of the corelist (-l) option. The patch adjusts the docs to use -l EAL option instead of the -c option. The patch only changes the docs and not the code as the -c option will continue to exist unless it is removed in the future. The -c option should be kept to maintain backward compatibility. Signed-off-by: Keith Wiles <keith.wiles@intel.com> Acked-by: John McNamara <john.mcnamara@intel.com>
261 lines
9.2 KiB
ReStructuredText
261 lines
9.2 KiB
ReStructuredText
How to get best performance with NICs on Intel platforms
|
|
========================================================
|
|
|
|
This document is a step-by-step guide for getting high performance from DPDK applications on Intel platforms.
|
|
|
|
|
|
Hardware and Memory Requirements
|
|
--------------------------------
|
|
|
|
For best performance use an Intel Xeon class server system such as Ivy Bridge, Haswell or newer.
|
|
|
|
Ensure that each memory channel has at least one memory DIMM inserted, and that the memory size for each is at least 4GB.
|
|
**Note**: this has one of the most direct effects on performance.
|
|
|
|
You can check the memory configuration using ``dmidecode`` as follows::
|
|
|
|
dmidecode -t memory | grep Locator
|
|
|
|
Locator: DIMM_A1
|
|
Bank Locator: NODE 1
|
|
Locator: DIMM_A2
|
|
Bank Locator: NODE 1
|
|
Locator: DIMM_B1
|
|
Bank Locator: NODE 1
|
|
Locator: DIMM_B2
|
|
Bank Locator: NODE 1
|
|
...
|
|
Locator: DIMM_G1
|
|
Bank Locator: NODE 2
|
|
Locator: DIMM_G2
|
|
Bank Locator: NODE 2
|
|
Locator: DIMM_H1
|
|
Bank Locator: NODE 2
|
|
Locator: DIMM_H2
|
|
Bank Locator: NODE 2
|
|
|
|
The sample output above shows a total of 8 channels, from ``A`` to ``H``, where each channel has 2 DIMMs.
|
|
|
|
You can also use ``dmidecode`` to determine the memory frequency::
|
|
|
|
dmidecode -t memory | grep Speed
|
|
|
|
Speed: 2133 MHz
|
|
Configured Clock Speed: 2134 MHz
|
|
Speed: Unknown
|
|
Configured Clock Speed: Unknown
|
|
Speed: 2133 MHz
|
|
Configured Clock Speed: 2134 MHz
|
|
Speed: Unknown
|
|
...
|
|
Speed: 2133 MHz
|
|
Configured Clock Speed: 2134 MHz
|
|
Speed: Unknown
|
|
Configured Clock Speed: Unknown
|
|
Speed: 2133 MHz
|
|
Configured Clock Speed: 2134 MHz
|
|
Speed: Unknown
|
|
Configured Clock Speed: Unknown
|
|
|
|
The output shows a speed of 2133 MHz (DDR4) and Unknown (not existing).
|
|
This aligns with the previous output which showed that each channel has one memory bar.
|
|
|
|
|
|
Network Interface Card Requirements
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Use a `DPDK supported <http://dpdk.org/doc/nics>`_ high end NIC such as the Intel XL710 40GbE.
|
|
|
|
Make sure each NIC has been flashed the latest version of NVM/firmware.
|
|
|
|
Use PCIe Gen3 slots, such as Gen3 ``x8`` or Gen3 ``x16`` because PCIe Gen2 slots don't provide enough bandwidth
|
|
for 2 x 10GbE and above.
|
|
You can use ``lspci`` to check the speed of a PCI slot using something like the following::
|
|
|
|
lspci -s 03:00.1 -vv | grep LnkSta
|
|
|
|
LnkSta: Speed 8GT/s, Width x8, TrErr- Train- SlotClk+ DLActive- ...
|
|
LnkSta2: Current De-emphasis Level: -6dB, EqualizationComplete+ ...
|
|
|
|
When inserting NICs into PCI slots always check the caption, such as CPU0 or CPU1 to indicate which socket it is connected to.
|
|
|
|
Care should be take with NUMA.
|
|
If you are using 2 or more ports from different NICs, it is best to ensure that these NICs are on the same CPU socket.
|
|
An example of how to determine this is shown further below.
|
|
|
|
|
|
BIOS Settings
|
|
~~~~~~~~~~~~~
|
|
|
|
The following are some recommendations on BIOS settings. Different platforms will have different BIOS naming
|
|
so the following is mainly for reference:
|
|
|
|
#. Before starting consider resetting all BIOS settings to their default.
|
|
|
|
#. Disable all power saving options such as: Power performance tuning, CPU P-State, CPU C3 Report and CPU C6 Report.
|
|
|
|
#. Select **Performance** as the CPU Power and Performance policy.
|
|
|
|
#. Disable Turbo Boost to ensure the performance scaling increases with the number of cores.
|
|
|
|
#. Set memory frequency to the highest available number, NOT auto.
|
|
|
|
#. Disable all virtualization options when you test the physical function of the NIC, and turn on ``VT-d`` if you wants to use VFIO.
|
|
|
|
|
|
Linux boot command line
|
|
~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The following are some recommendations on GRUB boot settings:
|
|
|
|
#. Use the default grub file as a starting point.
|
|
|
|
#. Reserve 1G huge pages via grub configurations. For example to reserve 8 huge pages of 1G size::
|
|
|
|
default_hugepagesz=1G hugepagesz=1G hugepages=8
|
|
|
|
#. Isolate CPU cores which will be used for DPDK. For example::
|
|
|
|
isolcpus=2,3,4,5,6,7,8
|
|
|
|
#. If it wants to use VFIO, use the following additional grub parameters::
|
|
|
|
iommu=pt intel_iommu=on
|
|
|
|
|
|
Configurations before running DPDK
|
|
----------------------------------
|
|
|
|
1. Build the DPDK target and reserve huge pages.
|
|
See the earlier section on :ref:`linux_gsg_hugepages` for more details.
|
|
|
|
The following shell commands may help with building and configuration:
|
|
|
|
.. code-block:: console
|
|
|
|
# Build DPDK target.
|
|
cd dpdk_folder
|
|
make install T=x86_64-native-linuxapp-gcc -j
|
|
|
|
# Get the hugepage size.
|
|
awk '/Hugepagesize/ {print $2}' /proc/meminfo
|
|
|
|
# Get the total huge page numbers.
|
|
awk '/HugePages_Total/ {print $2} ' /proc/meminfo
|
|
|
|
# Unmount the hugepages.
|
|
umount `awk '/hugetlbfs/ {print $2}' /proc/mounts`
|
|
|
|
# Create the hugepage mount folder.
|
|
mkdir -p /mnt/huge
|
|
|
|
# Mount to the specific folder.
|
|
mount -t hugetlbfs nodev /mnt/huge
|
|
|
|
2. Check the CPU layout using using the DPDK ``cpu_layout`` utility:
|
|
|
|
.. code-block:: console
|
|
|
|
cd dpdk_folder
|
|
|
|
usertools/cpu_layout.py
|
|
|
|
Or run ``lscpu`` to check the the cores on each socket.
|
|
|
|
3. Check your NIC id and related socket id:
|
|
|
|
.. code-block:: console
|
|
|
|
# List all the NICs with PCI address and device IDs.
|
|
lspci -nn | grep Eth
|
|
|
|
For example suppose your output was as follows::
|
|
|
|
82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
|
|
82:00.1 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
|
|
85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
|
|
85:00.1 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
|
|
|
|
Check the PCI device related numa node id:
|
|
|
|
.. code-block:: console
|
|
|
|
cat /sys/bus/pci/devices/0000\:xx\:00.x/numa_node
|
|
|
|
Usually ``0x:00.x`` is on socket 0 and ``8x:00.x`` is on socket 1.
|
|
**Note**: To get the best performance, ensure that the core and NICs are in the same socket.
|
|
In the example above ``85:00.0`` is on socket 1 and should be used by cores on socket 1 for the best performance.
|
|
|
|
4. Bind the test ports to DPDK compatible drivers, such as igb_uio. For example bind two ports to a DPDK compatible driver and check the status:
|
|
|
|
.. code-block:: console
|
|
|
|
|
|
# Bind ports 82:00.0 and 85:00.0 to dpdk driver
|
|
./dpdk_folder/usertools/dpdk-devbind.py -b igb_uio 82:00.0 85:00.0
|
|
|
|
# Check the port driver status
|
|
./dpdk_folder/usertools/dpdk-devbind.py --status
|
|
|
|
See ``dpdk-devbind.py --help`` for more details.
|
|
|
|
|
|
More details about DPDK setup and Linux kernel requirements see :ref:`linux_gsg_compiling_dpdk`.
|
|
|
|
|
|
Example of getting best performance for an Intel NIC
|
|
----------------------------------------------------
|
|
|
|
The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with an
|
|
Intel server platform and Intel XL710 NICs.
|
|
For specific 40G NIC configuration please refer to the i40e NIC guide.
|
|
|
|
The example scenario is to get best performance with two Intel XL710 40GbE ports.
|
|
See :numref:`figure_intel_perf_test_setup` for the performance test setup.
|
|
|
|
.. _figure_intel_perf_test_setup:
|
|
|
|
.. figure:: img/intel_perf_test_setup.*
|
|
|
|
Performance Test Setup
|
|
|
|
|
|
1. Add two Intel XL710 NICs to the platform, and use one port per card to get best performance.
|
|
The reason for using two NICs is to overcome a PCIe Gen3's limitation since it cannot provide 80G bandwidth
|
|
for two 40G ports, but two different PCIe Gen3 x8 slot can.
|
|
Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
|
|
|
|
82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
|
|
85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
|
|
|
|
2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
|
|
|
|
3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
|
|
In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
|
|
are 18-35 and 54-71.
|
|
Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
|
|
cores from different cores (e.g core18 and core19).
|
|
|
|
4. Bind these two ports to igb_uio.
|
|
|
|
5. As to XL710 40G port, we need at least two queue pairs to achieve best performance, then two queues per port
|
|
will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
|
|
|
|
6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
|
|
Compile the ``l3fwd sample`` with the default lpm mode.
|
|
|
|
7. The command line of running l3fwd would be something like the followings::
|
|
|
|
./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
|
|
-- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
|
|
|
|
This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
|
|
core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
|
|
|
|
|
|
8. Configure the traffic at a traffic generator.
|
|
|
|
* Start creating a stream on packet generator.
|
|
|
|
* Set the Ethernet II type to 0x0800.
|