2c8f1396f7
Refer the section which explains driver compilation and running of testpmd in Linux, instead of describing it in driver documentation. Signed-off-by: Shijith Thotton <shijith.thotton@caviumnetworks.com> Signed-off-by: Jerin Jacob <jerin.jacob@caviumnetworks.com>
378 lines
14 KiB
ReStructuredText
378 lines
14 KiB
ReStructuredText
.. BSD LICENSE
|
|
Copyright (C) Cavium networks Ltd. 2016.
|
|
All rights reserved.
|
|
|
|
Redistribution and use in source and binary forms, with or without
|
|
modification, are permitted provided that the following conditions
|
|
are met:
|
|
|
|
* Redistributions of source code must retain the above copyright
|
|
notice, this list of conditions and the following disclaimer.
|
|
* Redistributions in binary form must reproduce the above copyright
|
|
notice, this list of conditions and the following disclaimer in
|
|
the documentation and/or other materials provided with the
|
|
distribution.
|
|
* Neither the name of Cavium networks nor the names of its
|
|
contributors may be used to endorse or promote products derived
|
|
from this software without specific prior written permission.
|
|
|
|
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
|
|
"AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
|
|
LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
|
|
A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
|
|
OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
|
|
SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
|
|
LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
|
|
DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
|
|
THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
|
|
(INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
|
|
OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
|
|
ThunderX NICVF Poll Mode Driver
|
|
===============================
|
|
|
|
The ThunderX NICVF PMD (**librte_pmd_thunderx_nicvf**) provides poll mode driver
|
|
support for the inbuilt NIC found in the **Cavium ThunderX** SoC family
|
|
as well as their virtual functions (VF) in SR-IOV context.
|
|
|
|
More information can be found at `Cavium Networks Official Website
|
|
<http://www.cavium.com/ThunderX_ARM_Processors.html>`_.
|
|
|
|
Features
|
|
--------
|
|
|
|
Features of the ThunderX PMD are:
|
|
|
|
- Multiple queues for TX and RX
|
|
- Receive Side Scaling (RSS)
|
|
- Packet type information
|
|
- Checksum offload
|
|
- Promiscuous mode
|
|
- Multicast mode
|
|
- Port hardware statistics
|
|
- Jumbo frames
|
|
- Link state information
|
|
- Scattered and gather for TX and RX
|
|
- VLAN stripping
|
|
- SR-IOV VF
|
|
- NUMA support
|
|
- Multi queue set support (up to 96 queues (12 queue sets)) per port
|
|
|
|
Supported ThunderX SoCs
|
|
-----------------------
|
|
- CN88xx
|
|
- CN81xx
|
|
- CN83xx
|
|
|
|
Prerequisites
|
|
-------------
|
|
- Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
|
|
|
|
Pre-Installation Configuration
|
|
------------------------------
|
|
|
|
Config File Options
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
The following options can be modified in the ``config`` file.
|
|
Please note that enabling debugging options may affect system performance.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_THUNDERX_NICVF_PMD`` (default ``y``)
|
|
|
|
Toggle compilation of the ``librte_pmd_thunderx_nicvf`` driver.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_THUNDERX_NICVF_DEBUG_INIT`` (default ``n``)
|
|
|
|
Toggle display of initialization related messages.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_THUNDERX_NICVF_DEBUG_RX`` (default ``n``)
|
|
|
|
Toggle display of receive fast path run-time message
|
|
|
|
- ``CONFIG_RTE_LIBRTE_THUNDERX_NICVF_DEBUG_TX`` (default ``n``)
|
|
|
|
Toggle display of transmit fast path run-time message
|
|
|
|
- ``CONFIG_RTE_LIBRTE_THUNDERX_NICVF_DEBUG_DRIVER`` (default ``n``)
|
|
|
|
Toggle display of generic debugging messages
|
|
|
|
- ``CONFIG_RTE_LIBRTE_THUNDERX_NICVF_DEBUG_MBOX`` (default ``n``)
|
|
|
|
Toggle display of PF mailbox related run-time check messages
|
|
|
|
Driver compilation and testing
|
|
------------------------------
|
|
|
|
Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
|
|
for details.
|
|
|
|
To compile the ThunderX NICVF PMD for Linux arm64 gcc,
|
|
use arm64-thunderx-linuxapp-gcc as target.
|
|
|
|
Linux
|
|
-----
|
|
|
|
SR-IOV: Prerequisites and sample Application Notes
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Current ThunderX NIC PF/VF kernel modules maps each physical Ethernet port
|
|
automatically to virtual function (VF) and presented them as PCIe-like SR-IOV device.
|
|
This section provides instructions to configure SR-IOV with Linux OS.
|
|
|
|
#. Verify PF devices capabilities using ``lspci``:
|
|
|
|
.. code-block:: console
|
|
|
|
lspci -vvv
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
0002:01:00.0 Ethernet controller: Cavium Networks Device a01e (rev 01)
|
|
...
|
|
Capabilities: [100 v1] Alternative Routing-ID Interpretation (ARI)
|
|
...
|
|
Capabilities: [180 v1] Single Root I/O Virtualization (SR-IOV)
|
|
...
|
|
Kernel driver in use: thunder-nic
|
|
...
|
|
|
|
.. note::
|
|
|
|
Unless ``thunder-nic`` driver is in use make sure your kernel config includes ``CONFIG_THUNDER_NIC_PF`` setting.
|
|
|
|
#. Verify VF devices capabilities and drivers using ``lspci``:
|
|
|
|
.. code-block:: console
|
|
|
|
lspci -vvv
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
0002:01:00.1 Ethernet controller: Cavium Networks Device 0011 (rev 01)
|
|
...
|
|
Capabilities: [100 v1] Alternative Routing-ID Interpretation (ARI)
|
|
...
|
|
Kernel driver in use: thunder-nicvf
|
|
...
|
|
|
|
0002:01:00.2 Ethernet controller: Cavium Networks Device 0011 (rev 01)
|
|
...
|
|
Capabilities: [100 v1] Alternative Routing-ID Interpretation (ARI)
|
|
...
|
|
Kernel driver in use: thunder-nicvf
|
|
...
|
|
|
|
.. note::
|
|
|
|
Unless ``thunder-nicvf`` driver is in use make sure your kernel config includes ``CONFIG_THUNDER_NIC_VF`` setting.
|
|
|
|
#. Pass VF device to VM context (PCIe Passthrough):
|
|
|
|
The VF devices may be passed through to the guest VM using qemu or
|
|
virt-manager or virsh etc.
|
|
|
|
Example qemu guest launch command:
|
|
|
|
.. code-block:: console
|
|
|
|
sudo qemu-system-aarch64 -name vm1 \
|
|
-machine virt,gic_version=3,accel=kvm,usb=off \
|
|
-cpu host -m 4096 \
|
|
-smp 4,sockets=1,cores=8,threads=1 \
|
|
-nographic -nodefaults \
|
|
-kernel <kernel image> \
|
|
-append "root=/dev/vda console=ttyAMA0 rw hugepagesz=512M hugepages=3" \
|
|
-device vfio-pci,host=0002:01:00.1 \
|
|
-drive file=<rootfs.ext3>,if=none,id=disk1,format=raw \
|
|
-device virtio-blk-device,scsi=off,drive=disk1,id=virtio-disk1,bootindex=1 \
|
|
-netdev tap,id=net0,ifname=tap0,script=/etc/qemu-ifup_thunder \
|
|
-device virtio-net-device,netdev=net0 \
|
|
-serial stdio \
|
|
-mem-path /dev/huge
|
|
|
|
#. Enable **VFIO-NOIOMMU** mode (optional):
|
|
|
|
.. code-block:: console
|
|
|
|
echo 1 > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode
|
|
|
|
.. note::
|
|
|
|
**VFIO-NOIOMMU** is required only when running in VM context and should not be enabled otherwise.
|
|
|
|
#. Running testpmd:
|
|
|
|
Follow instructions available in the document
|
|
:ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
|
|
to run testpmd.
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
./arm64-thunderx-linuxapp-gcc/app/testpmd -l 0-3 -n 4 -w 0002:01:00.2 \
|
|
-- -i --disable-hw-vlan-filter --disable-crc-strip --no-flush-rx \
|
|
--port-topology=loop
|
|
|
|
...
|
|
|
|
PMD: rte_nicvf_pmd_init(): librte_pmd_thunderx nicvf version 1.0
|
|
|
|
...
|
|
EAL: probe driver: 177d:11 rte_nicvf_pmd
|
|
EAL: using IOMMU type 1 (Type 1)
|
|
EAL: PCI memory mapped at 0x3ffade50000
|
|
EAL: Trying to map BAR 4 that contains the MSI-X table.
|
|
Trying offsets: 0x40000000000:0x0000, 0x10000:0x1f0000
|
|
EAL: PCI memory mapped at 0x3ffadc60000
|
|
PMD: nicvf_eth_dev_init(): nicvf: device (177d:11) 2:1:0:2
|
|
PMD: nicvf_eth_dev_init(): node=0 vf=1 mode=tns-bypass sqs=false
|
|
loopback_supported=true
|
|
PMD: nicvf_eth_dev_init(): Port 0 (177d:11) mac=a6:c6:d9:17:78:01
|
|
Interactive-mode selected
|
|
Configuring Port 0 (socket 0)
|
|
...
|
|
|
|
PMD: nicvf_dev_configure(): Configured ethdev port0 hwcap=0x0
|
|
Port 0: A6:C6:D9:17:78:01
|
|
Checking link statuses...
|
|
Port 0 Link Up - speed 10000 Mbps - full-duplex
|
|
Done
|
|
testpmd>
|
|
|
|
Multiple Queue Set per DPDK port configuration
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
There are two types of VFs:
|
|
|
|
- Primary VF
|
|
- Secondary VF
|
|
|
|
Each port consists of a primary VF and n secondary VF(s). Each VF provides 8 Tx/Rx queues to a port.
|
|
When a given port is configured to use more than 8 queues, it requires one (or more) secondary VF.
|
|
Each secondary VF adds 8 additional queues to the queue set.
|
|
|
|
During PMD driver initialization, the primary VF's are enumerated by checking the
|
|
specific flag (see sqs message in DPDK boot log - sqs indicates secondary queue set).
|
|
They are at the beginning of VF list (the remain ones are secondary VF's).
|
|
|
|
The primary VFs are used as master queue sets. Secondary VFs provide
|
|
additional queue sets for primary ones. If a port is configured for more then
|
|
8 queues than it will request for additional queues from secondary VFs.
|
|
|
|
Secondary VFs cannot be shared between primary VFs.
|
|
|
|
Primary VFs are present on the beginning of the 'Network devices using kernel
|
|
driver' list, secondary VFs are on the remaining on the remaining part of the list.
|
|
|
|
.. note::
|
|
|
|
The VNIC driver in the multiqueue setup works differently than other drivers like `ixgbe`.
|
|
We need to bind separately each specific queue set device with the ``usertools/dpdk-devbind.py`` utility.
|
|
|
|
.. note::
|
|
|
|
Depending on the hardware used, the kernel driver sets a threshold ``vf_id``. VFs that try to attached with an id below or equal to
|
|
this boundary are considered primary VFs. VFs that try to attach with an id above this boundary are considered secondary VFs.
|
|
|
|
|
|
Example device binding
|
|
~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
If a system has three interfaces, a total of 18 VF devices will be created
|
|
on a non-NUMA machine.
|
|
|
|
.. note::
|
|
|
|
NUMA systems have 12 VFs per port and non-NUMA 6 VFs per port.
|
|
|
|
.. code-block:: console
|
|
|
|
# usertools/dpdk-devbind.py --status
|
|
|
|
Network devices using DPDK-compatible driver
|
|
============================================
|
|
<none>
|
|
|
|
Network devices using kernel driver
|
|
===================================
|
|
0000:01:10.0 'Device a026' if= drv=thunder-BGX unused=vfio-pci,uio_pci_generic
|
|
0000:01:10.1 'Device a026' if= drv=thunder-BGX unused=vfio-pci,uio_pci_generic
|
|
0002:01:00.0 'Device a01e' if= drv=thunder-nic unused=vfio-pci,uio_pci_generic
|
|
0002:01:00.1 'Device 0011' if=eth0 drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:00.2 'Device 0011' if=eth1 drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:00.3 'Device 0011' if=eth2 drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:00.4 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:00.5 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:00.6 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:00.7 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:01.0 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:01.1 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:01.2 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:01.3 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:01.4 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:01.5 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:01.6 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:01.7 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:02.0 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:02.1 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
0002:01:02.2 'Device 0011' if= drv=thunder-nicvf unused=vfio-pci,uio_pci_generic
|
|
|
|
Other network devices
|
|
=====================
|
|
0002:00:03.0 'Device a01f' unused=vfio-pci,uio_pci_generic
|
|
|
|
|
|
We want to bind two physical interfaces with 24 queues each device, we attach two primary VFs
|
|
and four secondary queues. In our example we choose two 10G interfaces eth1 (0002:01:00.2) and eth2 (0002:01:00.3).
|
|
We will choose four secondary queue sets from the ending of the list (0002:01:01.7-0002:01:02.2).
|
|
|
|
|
|
#. Bind two primary VFs to the ``vfio-pci`` driver:
|
|
|
|
.. code-block:: console
|
|
|
|
usertools/dpdk-devbind.py -b vfio-pci 0002:01:00.2
|
|
usertools/dpdk-devbind.py -b vfio-pci 0002:01:00.3
|
|
|
|
#. Bind four primary VFs to the ``vfio-pci`` driver:
|
|
|
|
.. code-block:: console
|
|
|
|
usertools/dpdk-devbind.py -b vfio-pci 0002:01:01.7
|
|
usertools/dpdk-devbind.py -b vfio-pci 0002:01:02.0
|
|
usertools/dpdk-devbind.py -b vfio-pci 0002:01:02.1
|
|
usertools/dpdk-devbind.py -b vfio-pci 0002:01:02.2
|
|
|
|
The nicvf thunderx driver will make use of attached secondary VFs automatically during the interface configuration stage.
|
|
|
|
Limitations
|
|
-----------
|
|
|
|
CRC striping
|
|
~~~~~~~~~~~~
|
|
|
|
The ThunderX SoC family NICs strip the CRC for every packets coming into the
|
|
host interface. So, CRC will be stripped even when the
|
|
``rxmode.hw_strip_crc`` member is set to 0 in ``struct rte_eth_conf``.
|
|
|
|
Maximum packet length
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The ThunderX SoC family NICs support a maximum of a 9K jumbo frame. The value
|
|
is fixed and cannot be changed. So, even when the ``rxmode.max_rx_pkt_len``
|
|
member of ``struct rte_eth_conf`` is set to a value lower than 9200, frames
|
|
up to 9200 bytes can still reach the host interface.
|
|
|
|
Maximum packet segments
|
|
~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The ThunderX SoC family NICs support up to 12 segments per packet when working
|
|
in scatter/gather mode. So, setting MTU will result with ``EINVAL`` when the
|
|
frame size does not fit in the maximum number of segments.
|