CXGBE Poll Mode Driver
|
|
======================
|
|
|
|
The CXGBE PMD (**librte_pmd_cxgbe**) provides poll mode driver support
|
|
for **Chelsio Terminator** 10/25/40/100 Gbps family of adapters. CXGBE PMD
|
|
has support for the latest Linux and FreeBSD operating systems.
|
|
|
|
CXGBEVF PMD provides poll mode driver support for SR-IOV Virtual functions
|
|
and has support for the latest Linux operating systems.
|
|
|
|
More information can be found at `Chelsio Communications Official Website
|
|
<http://www.chelsio.com>`_.
|
|
|
|
Features
|
|
--------
|
|
|
|
CXGBE and CXGBEVF PMD has support for:
|
|
|
|
- Multiple queues for TX and RX
|
|
- Receiver Side Steering (RSS)
|
|
Receiver Side Steering (RSS) on IPv4, IPv6, IPv4-TCP/UDP, IPv6-TCP/UDP.
|
|
For 4-tuple, enabling 'RSS on TCP' and 'RSS on TCP + UDP' is supported.
|
|
- VLAN filtering
|
|
- Checksum offload
|
|
- Promiscuous mode
|
|
- All multicast mode
|
|
- Port hardware statistics
|
|
- Jumbo frames
|
|
|
|
Limitations
|
|
-----------
|
|
|
|
The Chelsio Terminator series of devices provide two/four ports but
|
|
expose a single PCI bus address, thus, librte_pmd_cxgbe registers
|
|
itself as a PCI driver that allocates one Ethernet device per detected
|
|
port.
|
|
|
|
For this reason, one cannot whitelist/blacklist a single port without
|
|
whitelisting/blacklisting the other ports on the same device.
|
|
|
|
.. _t5-nics:
|
|
|
|
Supported Chelsio T5 NICs
|
|
-------------------------
|
|
|
|
- 1G NICs: T502-BT
|
|
- 10G NICs: T520-BT, T520-CR, T520-LL-CR, T520-SO-CR, T540-CR
|
|
- 40G NICs: T580-CR, T580-LP-CR, T580-SO-CR
|
|
- Other T5 NICs: T522-CR
|
|
|
|
.. _t6-nics:
|
|
|
|
Supported Chelsio T6 NICs
|
|
-------------------------
|
|
|
|
- 25G NICs: T6425-CR, T6225-CR, T6225-LL-CR, T6225-SO-CR
|
|
- 100G NICs: T62100-CR, T62100-LP-CR, T62100-SO-CR
|
|
|
|
Supported SR-IOV Chelsio NICs
|
|
-----------------------------
|
|
|
|
SR-IOV virtual functions are supported on all the Chelsio NICs listed
|
|
in :ref:`t5-nics` and :ref:`t6-nics`.
|
|
|
|
Prerequisites
|
|
-------------
|
|
|
|
- Requires firmware version **1.17.14.0** and higher. Visit
|
|
`Chelsio Download Center <http://service.chelsio.com>`_ to get latest firmware
|
|
bundled with the latest Chelsio Unified Wire package.
|
|
|
|
For Linux, installing and loading the latest cxgb4 kernel driver from the
|
|
Chelsio Unified Wire package should get you the latest firmware. More
|
|
information can be obtained from the User Guide that is bundled with the
|
|
Chelsio Unified Wire package.
|
|
|
|
For FreeBSD, the latest firmware obtained from the Chelsio Unified Wire
|
|
package must be manually flashed via cxgbetool available in FreeBSD source
|
|
repository.
|
|
|
|
Instructions on how to manually flash the firmware are given in section
|
|
:ref:`linux-installation` for Linux and section :ref:`freebsd-installation`
|
|
for FreeBSD.
|
|
|
|
Pre-Installation Configuration
|
|
------------------------------
|
|
|
|
Config File Options
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
The following options can be modified in the ``.config`` file. Please note that
|
|
enabling debugging options may affect system performance.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_CXGBE_PMD`` (default **y**)
|
|
|
|
Toggle compilation of librte_pmd_cxgbe driver.
|
|
|
|
.. note::
|
|
|
|
This controls compilation of both CXGBE and CXGBEVF PMD.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_CXGBE_DEBUG`` (default **n**)
|
|
|
|
Toggle display of generic debugging messages.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_CXGBE_DEBUG_REG`` (default **n**)
|
|
|
|
Toggle display of registers related run-time check messages.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_CXGBE_DEBUG_MBOX`` (default **n**)
|
|
|
|
Toggle display of firmware mailbox related run-time check messages.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_CXGBE_DEBUG_TX`` (default **n**)
|
|
|
|
Toggle display of transmission data path run-time check messages.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_CXGBE_DEBUG_RX`` (default **n**)
|
|
|
|
Toggle display of receiving data path run-time check messages.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_CXGBE_TPUT`` (default **y**)
|
|
|
|
Toggle behaviour to prefer Throughput or Latency.
|
|
|
|
Runtime Options
|
|
~~~~~~~~~~~~~~~
|
|
|
|
The following ``devargs`` options can be enabled at runtime. They must
|
|
be passed as part of EAL arguments. For example,
|
|
|
|
.. code-block:: console
|
|
|
|
testpmd -w 02:00.4,keep_ovlan=1 -- -i
|
|
|
|
- ``keep_ovlan`` (default **0**)
|
|
|
|
Toggle behaviour to keep/strip outer VLAN in Q-in-Q packets. If
|
|
enabled, the outer VLAN tag is preserved in Q-in-Q packets. Otherwise,
|
|
the outer VLAN tag is stripped in Q-in-Q packets.
|
|
|
|
.. _driver-compilation:
|
|
|
|
Driver compilation and testing
|
|
------------------------------
|
|
|
|
Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
|
|
for details.
|
|
|
|
Linux
|
|
-----
|
|
|
|
.. _linux-installation:
|
|
|
|
Linux Installation
|
|
~~~~~~~~~~~~~~~~~~
|
|
|
|
Steps to manually install the latest firmware from the downloaded Chelsio
|
|
Unified Wire package for Linux operating system are as follows:
|
|
|
|
#. Load the kernel module:
|
|
|
|
.. code-block:: console
|
|
|
|
modprobe cxgb4
|
|
|
|
#. Use ifconfig to get the interface name assigned to Chelsio card:
|
|
|
|
.. code-block:: console
|
|
|
|
ifconfig -a | grep "00:07:43"
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
p1p1 Link encap:Ethernet HWaddr 00:07:43:2D:EA:C0
|
|
p1p2 Link encap:Ethernet HWaddr 00:07:43:2D:EA:C8
|
|
|
|
#. Install cxgbtool:
|
|
|
|
.. code-block:: console
|
|
|
|
cd <path_to_uwire>/tools/cxgbtool
|
|
make install
|
|
|
|
#. Use cxgbtool to load the firmware config file onto the card:
|
|
|
|
.. code-block:: console
|
|
|
|
cxgbtool p1p1 loadcfg <path_to_uwire>/src/network/firmware/t5-config.txt
|
|
|
|
#. Use cxgbtool to load the firmware image onto the card:
|
|
|
|
.. code-block:: console
|
|
|
|
cxgbtool p1p1 loadfw <path_to_uwire>/src/network/firmware/t5fw-*.bin
|
|
|
|
#. Unload and reload the kernel module:
|
|
|
|
.. code-block:: console
|
|
|
|
modprobe -r cxgb4
|
|
modprobe cxgb4
|
|
|
|
#. Verify with ethtool:
|
|
|
|
.. code-block:: console
|
|
|
|
ethtool -i p1p1 | grep "firmware"
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
firmware-version: 1.17.14.0, TP 0.1.4.9
|
|
|
|
Running testpmd
|
|
~~~~~~~~~~~~~~~
|
|
|
|
This section demonstrates how to launch **testpmd** with Chelsio
|
|
devices managed by librte_pmd_cxgbe in Linux operating system.
|
|
|
|
#. Load the kernel module:
|
|
|
|
.. code-block:: console
|
|
|
|
modprobe cxgb4
|
|
|
|
#. Get the PCI bus addresses of the interfaces bound to cxgb4 driver:
|
|
|
|
.. code-block:: console
|
|
|
|
dmesg | tail -2
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
cxgb4 0000:02:00.4 p1p1: renamed from eth0
|
|
cxgb4 0000:02:00.4 p1p2: renamed from eth1
|
|
|
|
.. note::
|
|
|
|
Both the interfaces of a Chelsio 2-port adapter are bound to the
|
|
same PCI bus address.
|
|
|
|
#. Unload the kernel module:
|
|
|
|
.. code-block:: console
|
|
|
|
modprobe -ar cxgb4 csiostor
|
|
|
|
#. Running testpmd
|
|
|
|
Follow instructions available in the document
|
|
:ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
|
|
to run testpmd.
|
|
|
|
.. note::
|
|
|
|
Currently, CXGBE PMD only supports the binding of PF4 for Chelsio NICs.
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
[...]
|
|
EAL: PCI device 0000:02:00.4 on NUMA socket -1
|
|
EAL: probe driver: 1425:5401 rte_cxgbe_pmd
|
|
EAL: PCI memory mapped at 0x7fd7c0200000
|
|
EAL: PCI memory mapped at 0x7fd77cdfd000
|
|
EAL: PCI memory mapped at 0x7fd7c10b7000
|
|
PMD: rte_cxgbe_pmd: fw: 1.17.14.0, TP: 0.1.4.9
|
|
PMD: rte_cxgbe_pmd: Coming up as MASTER: Initializing adapter
|
|
Interactive-mode selected
|
|
Configuring Port 0 (socket 0)
|
|
Port 0: 00:07:43:2D:EA:C0
|
|
Configuring Port 1 (socket 0)
|
|
Port 1: 00:07:43:2D:EA:C8
|
|
Checking link statuses...
|
|
PMD: rte_cxgbe_pmd: Port0: passive DA port module inserted
|
|
PMD: rte_cxgbe_pmd: Port1: passive DA port module inserted
|
|
Port 0 Link Up - speed 10000 Mbps - full-duplex
|
|
Port 1 Link Up - speed 10000 Mbps - full-duplex
|
|
Done
|
|
testpmd>
|
|
|
|
.. note::
|
|
|
|
Flow control pause TX/RX is disabled by default and can be enabled via
|
|
testpmd. Refer section :ref:`flow-control` for more details.
|
|
|
|
Configuring SR-IOV Virtual Functions
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
This section demonstrates how to enable SR-IOV virtual functions
|
|
on Chelsio NICs and demonstrates how to run testpmd with SR-IOV
|
|
virtual functions.
|
|
|
|
#. Load the kernel module:
|
|
|
|
.. code-block:: console
|
|
|
|
modprobe cxgb4
|
|
|
|
#. Get the PCI bus addresses of the interfaces bound to cxgb4 driver:
|
|
|
|
.. code-block:: console
|
|
|
|
dmesg | tail -2
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
cxgb4 0000:02:00.4 p1p1: renamed from eth0
|
|
cxgb4 0000:02:00.4 p1p2: renamed from eth1
|
|
|
|
.. note::
|
|
|
|
Both the interfaces of a Chelsio 2-port adapter are bound to the
|
|
same PCI bus address.
|
|
|
|
#. Use ifconfig to get the interface name assigned to Chelsio card:
|
|
|
|
.. code-block:: console
|
|
|
|
ifconfig -a | grep "00:07:43"
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
p1p1 Link encap:Ethernet HWaddr 00:07:43:2D:EA:C0
|
|
p1p2 Link encap:Ethernet HWaddr 00:07:43:2D:EA:C8
|
|
|
|
#. Bring up the interfaces:
|
|
|
|
.. code-block:: console
|
|
|
|
ifconfig p1p1 up
|
|
ifconfig p1p2 up
|
|
|
|
#. Instantiate SR-IOV Virtual Functions. PF0..3 can be used for
|
|
SR-IOV VFs. Multiple VFs can be instantiated on each of PF0..3.
|
|
To instantiate one SR-IOV VF on each PF0 and PF1:
|
|
|
|
.. code-block:: console
|
|
|
|
echo 1 > /sys/bus/pci/devices/0000\:02\:00.0/sriov_numvfs
|
|
echo 1 > /sys/bus/pci/devices/0000\:02\:00.1/sriov_numvfs
|
|
|
|
#. Get the PCI bus addresses of the virtual functions:
|
|
|
|
.. code-block:: console
|
|
|
|
lspci | grep -i "Chelsio" | grep -i "VF"
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
02:01.0 Ethernet controller: Chelsio Communications Inc T540-CR Unified Wire Ethernet Controller [VF]
|
|
02:01.1 Ethernet controller: Chelsio Communications Inc T540-CR Unified Wire Ethernet Controller [VF]
|
|
|
|
#. Running testpmd
|
|
|
|
Follow instructions available in the document
|
|
:ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
|
|
to bind virtual functions and run testpmd.
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
[...]
|
|
EAL: PCI device 0000:02:01.0 on NUMA socket 0
|
|
EAL: probe driver: 1425:5803 net_cxgbevf
|
|
PMD: rte_cxgbe_pmd: Firmware version: 1.17.14.0
|
|
PMD: rte_cxgbe_pmd: TP Microcode version: 0.1.4.9
|
|
PMD: rte_cxgbe_pmd: Chelsio rev 0
|
|
PMD: rte_cxgbe_pmd: No bootstrap loaded
|
|
PMD: rte_cxgbe_pmd: No Expansion ROM loaded
|
|
PMD: rte_cxgbe_pmd: 0000:02:01.0 Chelsio rev 0 1G/10GBASE-SFP
|
|
EAL: PCI device 0000:02:01.1 on NUMA socket 0
|
|
EAL: probe driver: 1425:5803 net_cxgbevf
|
|
PMD: rte_cxgbe_pmd: Firmware version: 1.17.14.0
|
|
PMD: rte_cxgbe_pmd: TP Microcode version: 0.1.4.9
|
|
PMD: rte_cxgbe_pmd: Chelsio rev 0
|
|
PMD: rte_cxgbe_pmd: No bootstrap loaded
|
|
PMD: rte_cxgbe_pmd: No Expansion ROM loaded
|
|
PMD: rte_cxgbe_pmd: 0000:02:01.1 Chelsio rev 0 1G/10GBASE-SFP
|
|
Configuring Port 0 (socket 0)
|
|
Port 0: 06:44:29:44:40:00
|
|
Configuring Port 1 (socket 0)
|
|
Port 1: 06:44:29:44:40:10
|
|
Checking link statuses...
|
|
Done
|
|
testpmd>
|
|
|
|
FreeBSD
|
|
-------
|
|
|
|
.. _freebsd-installation:
|
|
|
|
FreeBSD Installation
|
|
~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Steps to manually install the latest firmware from the downloaded Chelsio
|
|
Unified Wire package for FreeBSD operating system are as follows:
|
|
|
|
#. Load the kernel module:
|
|
|
|
.. code-block:: console
|
|
|
|
kldload if_cxgbe
|
|
|
|
#. Use dmesg to get the t5nex instance assigned to the Chelsio card:
|
|
|
|
.. code-block:: console
|
|
|
|
dmesg | grep "t5nex"
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
t5nex0: <Chelsio T520-CR> irq 16 at device 0.4 on pci2
|
|
cxl0: <port 0> on t5nex0
|
|
cxl1: <port 1> on t5nex0
|
|
t5nex0: PCIe x8, 2 ports, 14 MSI-X interrupts, 31 eq, 13 iq
|
|
|
|
In the example above, a Chelsio T520-CR card is bound to a t5nex0 instance.
|
|
|
|
#. Install cxgbetool from FreeBSD source repository:
|
|
|
|
.. code-block:: console
|
|
|
|
cd <path_to_FreeBSD_source>/tools/tools/cxgbetool/
|
|
make && make install
|
|
|
|
#. Use cxgbetool to load the firmware image onto the card:
|
|
|
|
.. code-block:: console
|
|
|
|
cxgbetool t5nex0 loadfw <path_to_uwire>/src/network/firmware/t5fw-*.bin
|
|
|
|
#. Unload and reload the kernel module:
|
|
|
|
.. code-block:: console
|
|
|
|
kldunload if_cxgbe
|
|
kldload if_cxgbe
|
|
|
|
#. Verify with sysctl:
|
|
|
|
.. code-block:: console
|
|
|
|
sysctl -a | grep "t5nex" | grep "firmware"
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
dev.t5nex.0.firmware_version: 1.17.14.0
|
|
|
|
Running testpmd
|
|
~~~~~~~~~~~~~~~
|
|
|
|
This section demonstrates how to launch **testpmd** with Chelsio
|
|
devices managed by librte_pmd_cxgbe in FreeBSD operating system.
|
|
|
|
#. Change to DPDK source directory where the target has been compiled in
|
|
section :ref:`driver-compilation`:
|
|
|
|
.. code-block:: console
|
|
|
|
cd <DPDK-source-directory>
|
|
|
|
#. Copy the contigmem kernel module to /boot/kernel directory:
|
|
|
|
.. code-block:: console
|
|
|
|
cp x86_64-native-bsdapp-clang/kmod/contigmem.ko /boot/kernel/
|
|
|
|
#. Add the following lines to /boot/loader.conf:
|
|
|
|
.. code-block:: console
|
|
|
|
# reserve 2 x 1G blocks of contiguous memory using contigmem driver
|
|
hw.contigmem.num_buffers=2
|
|
hw.contigmem.buffer_size=1073741824
|
|
# load contigmem module during boot process
|
|
contigmem_load="YES"
|
|
|
|
The above lines load the contigmem kernel module during boot process and
|
|
allocate 2 x 1G blocks of contiguous memory to be used for DPDK later on.
|
|
This is to avoid issues with potential memory fragmentation during later
|
|
system up time, which may result in failure of allocating the contiguous
|
|
memory required for the contigmem kernel module.
|
|
|
|
#. Restart the system and ensure the contigmem module is loaded successfully:
|
|
|
|
.. code-block:: console
|
|
|
|
reboot
|
|
kldstat | grep "contigmem"
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
2 1 0xffffffff817f1000 3118 contigmem.ko
|
|
|
|
#. Repeat step 1 to ensure that you are in the DPDK source directory.
|
|
|
|
#. Load the cxgbe kernel module:
|
|
|
|
.. code-block:: console
|
|
|
|
kldload if_cxgbe
|
|
|
|
#. Get the PCI bus addresses of the interfaces bound to t5nex driver:
|
|
|
|
.. code-block:: console
|
|
|
|
pciconf -l | grep "t5nex"
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
t5nex0@pci0:2:0:4: class=0x020000 card=0x00001425 chip=0x54011425 rev=0x00
|
|
|
|
In the above example, the t5nex0 is bound to 2:0:4 bus address.
|
|
|
|
.. note::
|
|
|
|
Both the interfaces of a Chelsio 2-port adapter are bound to the
|
|
same PCI bus address.
|
|
|
|
#. Unload the kernel module:
|
|
|
|
.. code-block:: console
|
|
|
|
kldunload if_cxgbe
|
|
|
|
#. Set the PCI bus addresses to hw.nic_uio.bdfs kernel environment parameter:
|
|
|
|
.. code-block:: console
|
|
|
|
kenv hw.nic_uio.bdfs="2:0:4"
|
|
|
|
This automatically binds 2:0:4 to nic_uio kernel driver when it is loaded in
|
|
the next step.
|
|
|
|
.. note::
|
|
|
|
Currently, CXGBE PMD only supports the binding of PF4 for Chelsio NICs.
|
|
|
|
#. Load nic_uio kernel driver:
|
|
|
|
.. code-block:: console
|
|
|
|
kldload ./x86_64-native-bsdapp-clang/kmod/nic_uio.ko
|
|
|
|
#. Start testpmd with basic parameters:
|
|
|
|
.. code-block:: console
|
|
|
|
./x86_64-native-bsdapp-clang/app/testpmd -l 0-3 -n 4 -w 0000:02:00.4 -- -i
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
[...]
|
|
EAL: PCI device 0000:02:00.4 on NUMA socket 0
|
|
EAL: probe driver: 1425:5401 rte_cxgbe_pmd
|
|
EAL: PCI memory mapped at 0x8007ec000
|
|
EAL: PCI memory mapped at 0x842800000
|
|
EAL: PCI memory mapped at 0x80086c000
|
|
PMD: rte_cxgbe_pmd: fw: 1.17.14.0, TP: 0.1.4.9
|
|
PMD: rte_cxgbe_pmd: Coming up as MASTER: Initializing adapter
|
|
Interactive-mode selected
|
|
Configuring Port 0 (socket 0)
|
|
Port 0: 00:07:43:2D:EA:C0
|
|
Configuring Port 1 (socket 0)
|
|
Port 1: 00:07:43:2D:EA:C8
|
|
Checking link statuses...
|
|
PMD: rte_cxgbe_pmd: Port0: passive DA port module inserted
|
|
PMD: rte_cxgbe_pmd: Port1: passive DA port module inserted
|
|
Port 0 Link Up - speed 10000 Mbps - full-duplex
|
|
Port 1 Link Up - speed 10000 Mbps - full-duplex
|
|
Done
|
|
testpmd>
|
|
|
|
.. note::
|
|
|
|
Flow control pause TX/RX is disabled by default and can be enabled via
|
|
testpmd. Refer section :ref:`flow-control` for more details.
|
|
|
|
Sample Application Notes
|
|
------------------------
|
|
|
|
.. _flow-control:
|
|
|
|
Enable/Disable Flow Control
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Flow control pause TX/RX is disabled by default and can be enabled via
|
|
testpmd as follows:
|
|
|
|
.. code-block:: console
|
|
|
|
testpmd> set flow_ctrl rx on tx on 0 0 0 0 mac_ctrl_frame_fwd off autoneg on 0
|
|
testpmd> set flow_ctrl rx on tx on 0 0 0 0 mac_ctrl_frame_fwd off autoneg on 1
|
|
|
|
To disable again, run:
|
|
|
|
.. code-block:: console
|
|
|
|
testpmd> set flow_ctrl rx off tx off 0 0 0 0 mac_ctrl_frame_fwd off autoneg off 0
|
|
testpmd> set flow_ctrl rx off tx off 0 0 0 0 mac_ctrl_frame_fwd off autoneg off 1
|
|
|
|
Jumbo Mode
|
|
~~~~~~~~~~
|
|
|
|
There are two ways to enable sending and receiving of jumbo frames via testpmd.
|
|
One method involves using the **mtu** command, which changes the mtu of an
|
|
individual port without having to stop the selected port. Another method
|
|
involves stopping all the ports first and then running **max-pkt-len** command
|
|
to configure the mtu of all the ports with a single command.
|
|
|
|
- To configure each port individually, run the mtu command as follows:
|
|
|
|
.. code-block:: console
|
|
|
|
testpmd> port config mtu 0 9000
|
|
testpmd> port config mtu 1 9000
|
|
|
|
- To configure all the ports at once, stop all the ports first and run the
|
|
max-pkt-len command as follows:
|
|
|
|
.. code-block:: console
|
|
|
|
testpmd> port stop all
|
|
testpmd> port config all max-pkt-len 9000
|