numam-dpdk/examples/vhost_xen/xen_vhost.h
David Marchand ff708facfc tailq: remove unneeded inclusions
Only keep inclusion where really needed.

Signed-off-by: David Marchand <david.marchand@6wind.com>
Acked-by: Neil Horman <nhorman@tuxdriver.com>
2015-03-10 11:47:46 +01:00

149 lines
4.9 KiB
C

/*-
* BSD LICENSE
*
* Copyright(c) 2010-2014 Intel Corporation. All rights reserved.
* All rights reserved.
*
* Redistribution and use in source and binary forms, with or without
* modification, are permitted provided that the following conditions
* are met:
*
* * Redistributions of source code must retain the above copyright
* notice, this list of conditions and the following disclaimer.
* * Redistributions in binary form must reproduce the above copyright
* notice, this list of conditions and the following disclaimer in
* the documentation and/or other materials provided with the
* distribution.
* * Neither the name of Intel Corporation nor the names of its
* contributors may be used to endorse or promote products derived
* from this software without specific prior written permission.
*
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
* "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
* LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
* A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
* OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
* SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
* LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
* DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
* THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
* (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
* OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
*/
#ifndef _XEN_VHOST_H_
#define _XEN_VHOST_H_
#include <stdint.h>
#include <rte_ether.h>
#include "virtio-net.h"
#define RTE_LOGTYPE_XENHOST RTE_LOGTYPE_USER1
#define XEN_VM_ROOTNODE_FMT "/local/domain/%d/control/dpdk"
#define XEN_VM_NODE_FMT "/local/domain/%d/control/dpdk/%s"
#define XEN_MEMPOOL_SUFFIX "mempool_gref"
#define XEN_RXVRING_SUFFIX "rx_vring_gref"
#define XEN_TXVRING_SUFFIX "tx_vring_gref"
#define XEN_GVA_SUFFIX "mempool_va"
#define XEN_VRINGFLAG_SUFFIX "vring_flag"
#define XEN_ADDR_SUFFIX "ether_addr"
#define VIRTIO_START "event_type_start_"
#define XEN_GREF_SPLITTOKEN ','
#define MAX_XENVIRT_MEMPOOL 16
#define MAX_VIRTIO 32
#define MAX_GREF_PER_NODE 64 /* 128 MB memory */
#define PAGE_SIZE 4096
#define PAGE_PFNNUM (PAGE_SIZE / sizeof(uint32_t))
#define XEN_GNTDEV_FNAME "/dev/xen/gntdev"
/* xen grant reference info in one grant node */
struct xen_gnt {
uint32_t gref; /* grant reference for this node */
union {
int gref; /* grant reference */
uint32_t pfn_num; /* guest pfn number of grant reference */
} gref_pfn[PAGE_PFNNUM];
}__attribute__((__packed__));
/* structure for mempool or vring node list */
struct xen_gntnode {
uint32_t gnt_num; /* grant reference number */
struct xen_gnt *gnt_info; /* grant reference info */
};
struct xen_vring {
uint32_t dom_id;
uint32_t virtio_idx; /* index of virtio device */
void *rxvring_addr; /* mapped virtual address of rxvring */
void *txvring_addr; /* mapped virtual address of txvring */
uint32_t rxpfn_num; /* number of gpfn for rxvring */
uint32_t txpfn_num; /* number of gpfn for txvring */
uint32_t *rxpfn_tbl; /* array of rxvring gpfn */
uint32_t *txpfn_tbl; /* array of txvring gpfn */
uint64_t *rx_pindex; /* index used to release rx grefs */
uint64_t *tx_pindex; /* index used to release tx grefs */
uint64_t flag_index;
uint8_t *flag; /* cleared to zero on guest unmap */
struct ether_addr addr; /* ethernet address of virtio device */
uint8_t removed;
};
struct xen_mempool {
uint32_t dom_id; /* guest domain id */
uint32_t pool_idx; /* index of memory pool */
void *gva; /* guest virtual address of mbuf pool */
void *hva; /* host virtual address of mbuf pool */
uint32_t mempfn_num; /* number of gpfn for mbuf pool */
uint32_t *mempfn_tbl; /* array of mbuf pool gpfn */
uint64_t *pindex; /* index used to release grefs */
};
struct xen_guest {
TAILQ_ENTRY(xen_guest) next;
int32_t dom_id; /* guest domain id */
uint32_t pool_num; /* number of mbuf pool of the guest */
uint32_t vring_num; /* number of virtio ports of the guest */
/* array contain the guest mbuf pool info */
struct xen_mempool mempool[MAX_XENVIRT_MEMPOOL];
/* array contain the guest rx/tx vring info */
struct xen_vring vring[MAX_VIRTIO];
};
TAILQ_HEAD(xen_guestlist, xen_guest);
int
parse_mempoolnode(struct xen_guest *guest);
int
xenhost_init(void);
int
parse_vringnode(struct xen_guest *guest, uint32_t virtio_idx);
int
parse_mempoolnode(struct xen_guest *guest);
void
cleanup_mempool(struct xen_mempool *mempool);
void
cleanup_vring(struct xen_vring *vring);
void
virtio_monitor_loop(void);
int
init_virtio_xen(struct virtio_net_device_ops const * const);
#endif