.. SPDX-License-Identifier: BSD-3-Clause
|
|
Copyright(c) 2010-2014 Intel Corporation.
|
|
|
|
Poll Mode Driver for Paravirtual VMXNET3 NIC
|
|
============================================
|
|
|
|
The VMXNET3 adapter is the next generation of a paravirtualized NIC, introduced by VMware* ESXi.
|
|
It is designed for performance, offers all the features available in VMXNET2, and adds several new features such as,
|
|
multi-queue support (also known as Receive Side Scaling, RSS),
|
|
IPv6 offloads, and MSI/MSI-X interrupt delivery.
|
|
One can use the same device in a DPDK application with VMXNET3 PMD introduced in DPDK API.
|
|
|
|
In this chapter, two setups with the use of the VMXNET3 PMD are demonstrated:
|
|
|
|
#. Vmxnet3 with a native NIC connected to a vSwitch
|
|
|
|
#. Vmxnet3 chaining VMs connected to a vSwitch
|
|
|
|
VMXNET3 Implementation in the DPDK
|
|
----------------------------------
|
|
|
|
For details on the VMXNET3 device, refer to the VMXNET3 driver's vmxnet3 directory and support manual from VMware*.
|
|
|
|
For performance details, refer to the following link from VMware:
|
|
|
|
`http://www.vmware.com/pdf/vsp_4_vmxnet3_perf.pdf <http://www.vmware.com/pdf/vsp_4_vmxnet3_perf.pdf>`_
|
|
|
|
As a PMD, the VMXNET3 driver provides the packet reception and transmission callbacks, vmxnet3_recv_pkts and vmxnet3_xmit_pkts.
|
|
|
|
The VMXNET3 PMD handles all the packet buffer memory allocation and resides in guest address space
|
|
and it is solely responsible to free that memory when not needed.
|
|
The packet buffers and features to be supported are made available to hypervisor via VMXNET3 PCI configuration space BARs.
|
|
During RX/TX, the packet buffers are exchanged by their GPAs,
|
|
and the hypervisor loads the buffers with packets in the RX case and sends packets to vSwitch in the TX case.
|
|
|
|
The VMXNET3 PMD is compiled with vmxnet3 device headers.
|
|
The interface is similar to that of the other PMDs available in the DPDK API.
|
|
The driver pre-allocates the packet buffers and loads the command ring descriptors in advance.
|
|
The hypervisor fills those packet buffers on packet arrival and write completion ring descriptors,
|
|
which are eventually pulled by the PMD.
|
|
After reception, the DPDK application frees the descriptors and loads new packet buffers for the coming packets.
|
|
The interrupts are disabled and there is no notification required.
|
|
This keeps performance up on the RX side, even though the device provides a notification feature.
|
|
|
|
In the transmit routine, the DPDK application fills packet buffer pointers in the descriptors of the command ring
|
|
and notifies the hypervisor.
|
|
In response the hypervisor takes packets and passes them to the vSwitch, It writes into the completion descriptors ring.
|
|
The rings are read by the PMD in the next transmit routine call and the buffers and descriptors are freed from memory.
|
|
|
|
Features and Limitations of VMXNET3 PMD
|
|
---------------------------------------
|
|
|
|
In release 1.6.0, the VMXNET3 PMD provides the basic functionality of packet reception and transmission.
|
|
There are several options available for filtering packets at VMXNET3 device level including:
|
|
|
|
#. MAC Address based filtering:
|
|
|
|
* Unicast, Broadcast, All Multicast modes - SUPPORTED BY DEFAULT
|
|
|
|
* Multicast with Multicast Filter table - NOT SUPPORTED
|
|
|
|
* Promiscuous mode - SUPPORTED
|
|
|
|
* RSS based load balancing between queues - SUPPORTED
|
|
|
|
#. VLAN filtering:
|
|
|
|
* VLAN tag based filtering without load balancing - SUPPORTED
|
|
|
|
.. note::
|
|
|
|
|
|
* Release 1.6.0 does not support separate headers and body receive cmd_ring and hence,
|
|
multiple segment buffers are not supported.
|
|
Only cmd_ring_0 is used for packet buffers, one for each descriptor.
|
|
|
|
* Receive and transmit of scattered packets is not supported.
|
|
|
|
* Multicast with Multicast Filter table is not supported.
|
|
|
|
Prerequisites
|
|
-------------
|
|
|
|
The following prerequisites apply:
|
|
|
|
* Before starting a VM, a VMXNET3 interface to a VM through VMware vSphere Client must be assigned.
|
|
This is shown in the figure below.
|
|
|
|
.. _figure_vmxnet3_int:
|
|
|
|
.. figure:: img/vmxnet3_int.*
|
|
|
|
Assigning a VMXNET3 interface to a VM using VMware vSphere Client
|
|
|
|
.. note::
|
|
|
|
Depending on the Virtual Machine type, the VMware vSphere Client shows Ethernet adaptors while adding an Ethernet device.
|
|
Ensure that the VM type used offers a VMXNET3 device. Refer to the VMware documentation for a listed of VMs.
|
|
|
|
.. note::
|
|
|
|
Follow the *DPDK Getting Started Guide* to setup the basic DPDK environment.
|
|
|
|
.. note::
|
|
|
|
Follow the *DPDK Sample Application's User Guide*, L2 Forwarding/L3 Forwarding and
|
|
TestPMD for instructions on how to run a DPDK application using an assigned VMXNET3 device.
|
|
|
|
VMXNET3 with a Native NIC Connected to a vSwitch
|
|
------------------------------------------------
|
|
|
|
This section describes an example setup for Phy-vSwitch-VM-Phy communication.
|
|
|
|
.. _figure_vswitch_vm:
|
|
|
|
.. figure:: img/vswitch_vm.*
|
|
|
|
VMXNET3 with a Native NIC Connected to a vSwitch
|
|
|
|
.. note::
|
|
|
|
Other instructions on preparing to use DPDK such as,
|
|
hugepage enabling, UIO port binding are not listed here.
|
|
Please refer to *DPDK Getting Started Guide and DPDK Sample Application's User Guide* for detailed instructions.
|
|
|
|
The packet reception and transmission flow path is::
|
|
|
|
Packet generator -> 82576
|
|
-> VMware ESXi vSwitch
|
|
-> VMXNET3 device
|
|
-> Guest VM VMXNET3 port 0 rx burst
|
|
-> Guest VM 82599 VF port 0 tx burst
|
|
-> 82599 VF
|
|
-> Packet generator
|
|
|
|
VMXNET3 Chaining VMs Connected to a vSwitch
|
|
-------------------------------------------
|
|
|
|
The following figure shows an example VM-to-VM communication over a Phy-VM-vSwitch-VM-Phy communication channel.
|
|
|
|
.. _figure_vm_vm_comms:
|
|
|
|
.. figure:: img/vm_vm_comms.*
|
|
|
|
VMXNET3 Chaining VMs Connected to a vSwitch
|
|
|
|
.. note::
|
|
|
|
When using the L2 Forwarding or L3 Forwarding applications,
|
|
a destination MAC address needs to be written in packets to hit the other VM's VMXNET3 interface.
|
|
|
|
In this example, the packet flow path is::
|
|
|
|
Packet generator -> 82599 VF
|
|
-> Guest VM 82599 port 0 rx burst
|
|
-> Guest VM VMXNET3 port 1 tx burst
|
|
-> VMXNET3 device
|
|
-> VMware ESXi vSwitch
|
|
-> VMXNET3 device
|
|
-> Guest VM VMXNET3 port 0 rx burst
|
|
-> Guest VM 82599 VF port 1 tx burst
|
|
-> 82599 VF
|
|
-> Packet generator
|