d7decefc37
When generating PDF with on an old system,
there are failures because of long tables:
vm_power_management.rst:420: ERROR: Malformed table.
Column span alignment problem in table line 5.
vm_power_management.rst:545: ERROR: Malformed table.
Column span alignment problem in table line 5.
vm_power_management.rst:754: ERROR: Malformed table.
Column span alignment problem in table line 5.
The tables (having only two columns) are replaced
with the more appropriate definition lists.
Fixes: 30d3aa861d
("doc: rework VM power manager user guide")
Signed-off-by: Thomas Monjalon <thomas@monjalon.net>
Acked-by: David Marchand <david.marchand@redhat.com>
943 lines
30 KiB
ReStructuredText
943 lines
30 KiB
ReStructuredText
.. SPDX-License-Identifier: BSD-3-Clause
|
||
Copyright(c) 2010-2014 Intel Corporation.
|
||
|
||
Virtual Machine Power Management Application
|
||
============================================
|
||
|
||
Applications running in virtual environments have an abstract view of
|
||
the underlying hardware on the host. Specifically, applications cannot
|
||
see the binding of virtual components to physical hardware. When looking
|
||
at CPU resourcing, the pinning of Virtual CPUs (vCPUs) to Physical CPUs
|
||
(pCPUs) on the host is not apparent to an application and this pinning
|
||
may change over time. In addition, operating systems on Virtual Machines
|
||
(VMs) do not have the ability to govern their own power policy. The
|
||
Machine Specific Registers (MSRs) for enabling P-state transitions are
|
||
not exposed to the operating systems running on the VMs.
|
||
|
||
The solution demonstrated in this sample application shows an example of
|
||
how a DPDK application can indicate its processing requirements using
|
||
VM-local only information (vCPU/lcore, and so on) to a host resident VM
|
||
Power Manager. The VM Power Manager is responsible for:
|
||
|
||
- **Accepting requests for frequency changes for a vCPU**
|
||
- **Translating the vCPU to a pCPU using libvirt**
|
||
- **Performing the change in frequency**
|
||
|
||
This application demonstrates the following features:
|
||
|
||
- **The handling of VM application requests to change frequency.**
|
||
VM applications can request frequency changes for a vCPU. The VM
|
||
Power Management Application uses libvirt to translate that
|
||
virtual CPU (vCPU) request to a physical CPU (pCPU) request and
|
||
performs the frequency change.
|
||
|
||
- **The acceptance of power management policies from VM applications.**
|
||
A VM application can send a policy to the host application. The
|
||
policy contains rules that define the power management behaviour
|
||
of the VM. The host application then applies the rules of the
|
||
policy independent of the VM application. For example, the
|
||
policy can contain time-of-day information for busy/quiet
|
||
periods, and the host application can scale up/down the relevant
|
||
cores when required. See :ref:`sending_policy` for information on
|
||
setting policy values.
|
||
|
||
- **Out-of-band monitoring of workloads using core hardware event counters.**
|
||
The host application can manage power for an application by looking
|
||
at the event counters of the cores and taking action based on the
|
||
branch miss/hit ratio. See :ref:`enabling_out_of_band`.
|
||
|
||
**Note**: This functionality also applies in non-virtualised environments.
|
||
|
||
In addition to the ``librte_power`` library used on the host, the
|
||
application uses a special version of ``librte_power`` on each VM, which
|
||
directs frequency changes and policies to the host monitor rather than
|
||
the APCI ``cpufreq`` ``sysfs`` interface used on the host in non-virtualised
|
||
environments.
|
||
|
||
.. _figure_vm_power_mgr_highlevel:
|
||
|
||
.. figure:: img/vm_power_mgr_highlevel.*
|
||
|
||
Highlevel Solution
|
||
|
||
In the above diagram, the DPDK Applications are shown running in
|
||
virtual machines, and the VM Power Monitor application is shown running
|
||
in the host.
|
||
|
||
**DPDK VM Application**
|
||
|
||
- Reuse ``librte_power`` interface, but uses an implementation that
|
||
forwards frequency requests to the host using a ``virtio-serial`` channel
|
||
- Each lcore has exclusive access to a single channel
|
||
- Sample application reuses ``l3fwd_power``
|
||
- A CLI for changing frequency from within a VM is also included
|
||
|
||
**VM Power Monitor**
|
||
|
||
- Accepts VM commands over ``virtio-serial`` endpoints, monitored
|
||
using ``epoll``
|
||
- Commands include the virtual core to be modified, using ``libvirt`` to get
|
||
the physical core mapping
|
||
- Uses ``librte_power`` to affect frequency changes using Linux userspace
|
||
power governor (``acpi_cpufreq`` OR ``intel_pstate`` driver)
|
||
- CLI: For adding VM channels to monitor, inspecting and changing channel
|
||
state, manually altering CPU frequency. Also allows for the changings
|
||
of vCPU to pCPU pinning
|
||
|
||
Sample Application Architecture Overview
|
||
----------------------------------------
|
||
|
||
The VM power management solution employs ``qemu-kvm`` to provide
|
||
communications channels between the host and VMs in the form of a
|
||
``virtio-serial`` connection that appears as a para-virtualised serial
|
||
device on a VM and can be configured to use various backends on the
|
||
host. For this example, the configuration of each ``virtio-serial`` endpoint
|
||
on the host as an ``AF_UNIX`` file socket, supporting poll/select and
|
||
``epoll`` for event notification. In this example, each channel endpoint on
|
||
the host is monitored for ``EPOLLIN`` events using ``epoll``. Each channel
|
||
is specified as ``qemu-kvm`` arguments or as ``libvirt`` XML for each VM,
|
||
where each VM can have several channels up to a maximum of 64 per VM. In this
|
||
example, each DPDK lcore on a VM has exclusive access to a channel.
|
||
|
||
To enable frequency changes from within a VM, the VM forwards a
|
||
``librte_power`` request over the ``virtio-serial`` channel to the host. Each
|
||
request contains the vCPU and power command (scale up/down/min/max). The
|
||
API for the host ``librte_power`` and guest ``librte_power`` is consistent
|
||
across environments, with the selection of VM or host implementation
|
||
determined automatically at runtime based on the environment. On
|
||
receiving a request, the host translates the vCPU to a pCPU using the
|
||
libvirt API before forwarding it to the host ``librte_power``.
|
||
|
||
|
||
.. _figure_vm_power_mgr_vm_request_seq:
|
||
|
||
.. figure:: img/vm_power_mgr_vm_request_seq.*
|
||
|
||
In addition to the ability to send power management requests to the
|
||
host, a VM can send a power management policy to the host. In some
|
||
cases, using a power management policy is a preferred option because it
|
||
can eliminate possible latency issues that can occur when sending power
|
||
management requests. Once the VM sends the policy to the host, the VM no
|
||
longer needs to worry about power management, because the host now
|
||
manages the power for the VM based on the policy. The policy can specify
|
||
power behavior that is based on incoming traffic rates or time-of-day
|
||
power adjustment (busy/quiet hour power adjustment for example). See
|
||
:ref:`sending_policy` for more information.
|
||
|
||
One method of power management is to sense how busy a core is when
|
||
processing packets and adjusting power accordingly. One technique for
|
||
doing this is to monitor the ratio of the branch miss to branch hits
|
||
counters and scale the core power accordingly. This technique is based
|
||
on the premise that when a core is not processing packets, the ratio of
|
||
branch misses to branch hits is very low, but when the core is
|
||
processing packets, it is measurably higher. The implementation of this
|
||
capability is as a policy of type ``BRANCH_RATIO``.
|
||
See :ref:`sending_policy` for more information on using the
|
||
BRANCH_RATIO policy option.
|
||
|
||
A JSON interface enables the specification of power management requests
|
||
and policies in JSON format. The JSON interfaces provide a more
|
||
convenient and more easily interpreted interface for the specification
|
||
of requests and policies. See :ref:`power_man_requests` for more information.
|
||
|
||
Performance Considerations
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
While the Haswell microarchitecture allows for independent power control
|
||
for each core, earlier microarchitectures do not offer such fine-grained
|
||
control. When deploying on pre-Haswell platforms, greater care must be
|
||
taken when selecting which cores are assigned to a VM, for example, a
|
||
core does not scale down in frequency until all of its siblings are
|
||
similarly scaled down.
|
||
|
||
Configuration
|
||
-------------
|
||
|
||
BIOS
|
||
~~~~
|
||
|
||
To use the power management features of the DPDK, you must enable
|
||
Enhanced Intel SpeedStep® Technology in the platform BIOS. Otherwise,
|
||
the ``sys`` file folder ``/sys/devices/system/cpu/cpu0/cpufreq`` does not
|
||
exist, and you cannot use CPU frequency-based power management. Refer to the
|
||
relevant BIOS documentation to determine how to access these settings.
|
||
|
||
Host Operating System
|
||
~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
The DPDK Power Management library can use either the ``acpi_cpufreq`` or
|
||
the ``intel_pstate`` kernel driver for the management of core frequencies. In
|
||
many cases, the ``intel_pstate`` driver is the default power management
|
||
environment.
|
||
|
||
Should the ``acpi-cpufreq driver`` be required, the ``intel_pstate``
|
||
module must be disabled, and the ``acpi-cpufreq`` module loaded in its place.
|
||
|
||
To disable the ``intel_pstate`` driver, add the following to the ``grub``
|
||
Linux command line:
|
||
|
||
``intel_pstate=disable``
|
||
|
||
On reboot, load the ``acpi_cpufreq`` module:
|
||
|
||
``modprobe acpi_cpufreq``
|
||
|
||
Hypervisor Channel Configuration
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Configure ``virtio-serial`` channels using ``libvirt`` XML.
|
||
The XML structure is as follows:
|
||
|
||
.. code-block:: XML
|
||
|
||
<name>{vm_name}</name>
|
||
<controller type='virtio-serial' index='0'>
|
||
<address type='pci' domain='0x0000' bus='0x00' slot='0x06' function='0x0'/>
|
||
</controller>
|
||
<channel type='unix'>
|
||
<source mode='bind' path='/tmp/powermonitor/{vm_name}.{channel_num}'/>
|
||
<target type='virtio' name='virtio.serial.port.poweragent.{vm_channel_num}'/>
|
||
<address type='virtio-serial' controller='0' bus='0' port='{N}'/>
|
||
</channel>
|
||
|
||
Where a single controller of type ``virtio-serial`` is created, up to 32
|
||
channels can be associated with a single controller, and multiple
|
||
controllers can be specified. The convention is to use the name of the
|
||
VM in the host path ``{vm_name}`` and to increment ``{channel_num}`` for each
|
||
channel. Likewise, the port value ``{N}`` must be incremented for each
|
||
channel.
|
||
|
||
On the host, for each channel to appear in the path, ensure the creation
|
||
of the ``/tmp/powermonitor/`` directory and the assignment of ``qemu``
|
||
permissions:
|
||
|
||
.. code-block:: console
|
||
|
||
mkdir /tmp/powermonitor/
|
||
chown qemu:qemu /tmp/powermonitor
|
||
|
||
Note that files and directories in ``/tmp`` are generally removed when
|
||
rebooting the host and you may need to perform the previous steps after
|
||
each reboot.
|
||
|
||
The serial device as it appears on a VM is configured with the target
|
||
element attribute name and must be in the form:
|
||
``virtio.serial.port.poweragent.{vm_channel_num}``, where
|
||
``vm_channel_num`` is typically the lcore channel to be used in
|
||
DPDK VM applications.
|
||
|
||
Each channel on a VM is present at:
|
||
|
||
``/dev/virtio-ports/virtio.serial.port.poweragent.{vm_channel_num}``
|
||
|
||
Compiling and Running the Host Application
|
||
------------------------------------------
|
||
|
||
Compiling the Host Application
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
For information on compiling the DPDK and sample applications, see
|
||
see :doc:`compiling`.
|
||
|
||
The application is located in the ``vm_power_manager`` subdirectory.
|
||
|
||
To build just the ``vm_power_manager`` application using ``make``:
|
||
|
||
.. code-block:: console
|
||
|
||
export RTE_SDK=/path/to/rte_sdk
|
||
export RTE_TARGET=build
|
||
cd ${RTE_SDK}/examples/vm_power_manager/
|
||
make
|
||
|
||
The resulting binary is ``${RTE_SDK}/build/examples/vm_power_manager``.
|
||
|
||
To build just the ``vm_power_manager`` application using ``meson``/``ninja``:
|
||
|
||
.. code-block:: console
|
||
|
||
export RTE_SDK=/path/to/rte_sdk
|
||
cd ${RTE_SDK}
|
||
meson build
|
||
cd build
|
||
ninja
|
||
meson configure -Dexamples=vm_power_manager
|
||
ninja
|
||
|
||
The resulting binary is ``${RTE_SDK}/build/examples/dpdk-vm_power_manager``.
|
||
|
||
Running the Host Application
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
The application does not have any specific command line options other
|
||
than the EAL options:
|
||
|
||
.. code-block:: console
|
||
|
||
./build/vm_power_mgr [EAL options]
|
||
|
||
The application requires exactly two cores to run. One core for the CLI
|
||
and the other for the channel endpoint monitor. For example, to run on
|
||
cores 0 and 1 on a system with four memory channels, issue the command:
|
||
|
||
.. code-block:: console
|
||
|
||
./build/vm_power_mgr -l 0-1 -n 4
|
||
|
||
After successful initialization, the VM Power Manager CLI prompt appears:
|
||
|
||
.. code-block:: console
|
||
|
||
vm_power>
|
||
|
||
Now, it is possible to add virtual machines to the VM Power Manager:
|
||
|
||
.. code-block:: console
|
||
|
||
vm_power> add_vm {vm_name}
|
||
|
||
When a ``{vm_name}`` is specified with the ``add_vm`` command, a lookup is
|
||
performed with ``libvirt`` to ensure that the VM exists. ``{vm_name}`` is a
|
||
unique identifier to associate channels with a particular VM and for
|
||
executing operations on a VM within the CLI. VMs do not have to be
|
||
running to add them.
|
||
|
||
It is possible to issue several commands from the CLI to manage VMs.
|
||
|
||
Remove the virtual machine identified by ``{vm_name}`` from the VM Power
|
||
Manager using the command:
|
||
|
||
.. code-block:: console
|
||
|
||
rm_vm {vm_name}
|
||
|
||
Add communication channels for the specified VM using the following
|
||
command. The ``virtio`` channels must be enabled in the VM configuration
|
||
(``qemu/libvirt``) and the associated VM must be active. ``{list}`` is a
|
||
comma-separated list of channel numbers to add. Specifying the keyword
|
||
``all`` attempts to add all channels for the VM:
|
||
|
||
.. code-block:: console
|
||
|
||
set_pcpu {vm_name} {vcpu} {pcpu}
|
||
|
||
Enable query of physical core information from a VM:
|
||
|
||
.. code-block:: console
|
||
|
||
set_query {vm_name} enable|disable
|
||
|
||
Manual control and inspection can also be carried in relation CPU frequency scaling:
|
||
|
||
Get the current frequency for each core specified in the mask:
|
||
|
||
.. code-block:: console
|
||
|
||
show_cpu_freq_mask {mask}
|
||
|
||
Set the current frequency for the cores specified in {core_mask} by scaling each up/down/min/max:
|
||
|
||
.. code-block:: console
|
||
|
||
add_channels {vm_name} {list}|all
|
||
|
||
Enable or disable the communication channels in ``{list}`` (comma-separated)
|
||
for the specified VM. Alternatively, replace ``list`` with the keyword
|
||
``all``. Disabled channels receive packets on the host. However, the commands
|
||
they specify are ignored. Set the status to enabled to begin processing
|
||
requests again:
|
||
|
||
.. code-block:: console
|
||
|
||
set_channel_status {vm_name} {list}|all enabled|disabled
|
||
|
||
Print to the CLI information on the specified VM. The information lists
|
||
the number of vCPUs, the pinning to pCPU(s) as a bit mask, along with
|
||
any communication channels associated with each VM, and the status of
|
||
each channel:
|
||
|
||
.. code-block:: console
|
||
|
||
show_vm {vm_name}
|
||
|
||
Set the binding of a virtual CPU on a VM with name ``{vm_name}`` to the
|
||
physical CPU mask:
|
||
|
||
.. code-block:: console
|
||
|
||
set_pcpu_mask {vm_name} {vcpu} {pcpu}
|
||
|
||
Set the binding of the virtual CPU on the VM to the physical CPU:
|
||
|
||
.. code-block:: console
|
||
|
||
set_pcpu {vm_name} {vcpu} {pcpu}
|
||
|
||
It is also possible to perform manual control and inspection in relation
|
||
to CPU frequency scaling.
|
||
|
||
Get the current frequency for each core specified in the mask:
|
||
|
||
.. code-block:: console
|
||
|
||
show_cpu_freq_mask {mask}
|
||
|
||
Set the current frequency for the cores specified in ``{core_mask}`` by
|
||
scaling each up/down/min/max:
|
||
|
||
.. code-block:: console
|
||
|
||
set_cpu_freq {core_mask} up|down|min|max
|
||
|
||
Get the current frequency for the specified core:
|
||
|
||
.. code-block:: console
|
||
|
||
show_cpu_freq {core_num}
|
||
|
||
Set the current frequency for the specified core by scaling up/down/min/max:
|
||
|
||
.. code-block:: console
|
||
|
||
set_cpu_freq {core_num} up|down|min|max
|
||
|
||
.. _enabling_out_of_band:
|
||
|
||
Command Line Options for Enabling Out-of-band Branch Ratio Monitoring
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
There are a couple of command line parameters for enabling the out-of-band
|
||
monitoring of branch ratios on cores doing busy polling using PMDs as
|
||
described below:
|
||
|
||
``--core-list {list of cores}``
|
||
Specify the list of cores to monitor the ratio of branch misses
|
||
to branch hits. A tightly-polling PMD thread has a very low
|
||
branch ratio, therefore the core frequency scales down to the
|
||
minimum allowed value. On receiving packets, the code path changes,
|
||
causing the branch ratio to increase. When the ratio goes above
|
||
the ratio threshold, the core frequency scales up to the maximum
|
||
allowed value.
|
||
|
||
``--branch-ratio {ratio}``
|
||
Specify a floating-point number that identifies the threshold at which
|
||
to scale up or down for the given workload. The default branch ratio
|
||
is 0.01 and needs adjustment for different workloads.
|
||
|
||
|
||
Compiling and Running the Guest Applications
|
||
--------------------------------------------
|
||
|
||
It is possible to use the ``l3fwd-power`` application (for example) with the
|
||
``vm_power_manager``.
|
||
|
||
The distribution also provides a guest CLI for validating the setup.
|
||
|
||
For both ``l3fwd-power`` and the guest CLI, the host application must use
|
||
the ``add_channels`` command to monitor the channels for the VM. To do this,
|
||
issue the following commands in the host application:
|
||
|
||
.. code-block:: console
|
||
|
||
vm_power> add_vm vmname
|
||
vm_power> add_channels vmname all
|
||
vm_power> set_channel_status vmname all enabled
|
||
vm_power> show_vm vmname
|
||
|
||
Compiling the Guest Application
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
For information on compiling DPDK and the sample applications in general,
|
||
see :doc:`compiling`.
|
||
|
||
For compiling and running the ``l3fwd-power`` sample application, see
|
||
:doc:`l3_forward_power_man`.
|
||
|
||
The application is in the ``guest_cli`` subdirectory under ``vm_power_manager``.
|
||
|
||
To build just the ``guest_vm_power_manager`` application using ``make``, issue
|
||
the following commands:
|
||
|
||
.. code-block:: console
|
||
|
||
export RTE_SDK=/path/to/rte_sdk
|
||
export RTE_TARGET=build
|
||
cd ${RTE_SDK}/examples/vm_power_manager/guest_cli/
|
||
make
|
||
|
||
The resulting binary is ``${RTE_SDK}/build/examples/guest_cli``.
|
||
|
||
**Note**: This sample application conditionally links in the Jansson JSON
|
||
library. Consequently, if you are using a multilib or cross-compile
|
||
environment, you may need to set the ``PKG_CONFIG_LIBDIR`` environmental
|
||
variable to point to the relevant ``pkgconfig`` folder so that the correct
|
||
library is linked in.
|
||
|
||
For example, if you are building for a 32-bit target, you could find the
|
||
correct directory using the following find command:
|
||
|
||
.. code-block:: console
|
||
|
||
# find /usr -type d -name pkgconfig
|
||
/usr/lib/i386-linux-gnu/pkgconfig
|
||
/usr/lib/x86_64-linux-gnu/pkgconfig
|
||
|
||
Then use:
|
||
|
||
.. code-block:: console
|
||
|
||
export PKG_CONFIG_LIBDIR=/usr/lib/i386-linux-gnu/pkgconfig
|
||
|
||
You then use the ``make`` command as normal, which should find the 32-bit
|
||
version of the library, if it installed. If not, the application builds
|
||
without the JSON interface functionality.
|
||
|
||
To build just the ``vm_power_manager`` application using ``meson``/``ninja``:
|
||
|
||
.. code-block:: console
|
||
|
||
export RTE_SDK=/path/to/rte_sdk
|
||
cd ${RTE_SDK}
|
||
meson build
|
||
cd build
|
||
ninja
|
||
meson configure -Dexamples=vm_power_manager/guest_cli
|
||
ninja
|
||
|
||
The resulting binary is ``${RTE_SDK}/build/examples/guest_cli``.
|
||
|
||
Running the Guest Application
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
The standard EAL command line parameters are necessary:
|
||
|
||
.. code-block:: console
|
||
|
||
./build/vm_power_mgr [EAL options] -- [guest options]
|
||
|
||
The guest example uses a channel for each lcore enabled. For example, to
|
||
run on cores 0, 1, 2 and 3:
|
||
|
||
.. code-block:: console
|
||
|
||
./build/guest_vm_power_mgr -l 0-3
|
||
|
||
.. _sending_policy:
|
||
|
||
Command Line Options Available When Sending a Policy to the Host
|
||
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
Optionally, there are several command line options for a user who needs
|
||
to send a power policy to the host application:
|
||
|
||
``--vm-name {name of guest vm}``
|
||
Allows the user to change the virtual machine name
|
||
passed down to the host application using the power policy.
|
||
The default is ubuntu2.
|
||
|
||
``--vcpu-list {list vm cores}``
|
||
A comma-separated list of cores in the VM that the user
|
||
wants the host application to monitor.
|
||
The list of cores in any VM starts at zero,
|
||
and the host application maps these to the physical cores
|
||
once the policy passes down to the host.
|
||
Valid syntax includes individual cores 2,3,4,
|
||
a range of cores 2-4, or a combination of both 1,3,5-7.
|
||
|
||
``--busy-hours {list of busy hours}``
|
||
A comma-separated list of hours in which to set the core
|
||
frequency to the maximum.
|
||
Valid syntax includes individual hours 2,3,4,
|
||
a range of hours 2-4, or a combination of both 1,3,5-7.
|
||
Valid hour values are 0 to 23.
|
||
|
||
``--quiet-hours {list of quiet hours}``
|
||
A comma-separated list of hours in which to set the core frequency
|
||
to minimum. Valid syntax includes individual hours 2,3,4,
|
||
a range of hours 2-4, or a combination of both 1,3,5-7.
|
||
Valid hour values are 0 to 23.
|
||
|
||
``--policy {policy type}``
|
||
The type of policy. This can be one of the following values:
|
||
|
||
- TRAFFIC - Based on incoming traffic rates on the NIC.
|
||
- TIME - Uses a busy/quiet hours policy.
|
||
- BRANCH_RATIO - Uses branch ratio counters to determine core busyness.
|
||
- WORKLOAD - Sets the frequency to low, medium or high
|
||
based on the received policy setting.
|
||
|
||
**Note**: Not all policy types need all parameters.
|
||
For example, BRANCH_RATIO only needs the vcpu-list parameter.
|
||
|
||
After successful initialization, the VM Power Manager Guest CLI prompt
|
||
appears:
|
||
|
||
.. code-block:: console
|
||
|
||
vm_power(guest)>
|
||
|
||
To change the frequency of an lcore, use a ``set_cpu_freq`` command similar
|
||
to the following:
|
||
|
||
.. code-block:: console
|
||
|
||
set_cpu_freq {core_num} up|down|min|max
|
||
|
||
where, ``{core_num}`` is the lcore and channel to change frequency by
|
||
scaling up/down/min/max.
|
||
|
||
To start an application, configure the power policy, and send it to the
|
||
host, use a command like the following:
|
||
|
||
.. code-block:: console
|
||
|
||
./build/guest_vm_power_mgr -l 0-3 -n 4 -- --vm-name=ubuntu --policy=BRANCH_RATIO --vcpu-list=2-4
|
||
|
||
Once the VM Power Manager Guest CLI appears, issuing the 'send_policy now' command
|
||
will send the policy to the host:
|
||
|
||
.. code-block:: console
|
||
|
||
send_policy now
|
||
|
||
Once the policy is sent to the host, the host application takes over the power monitoring
|
||
of the specified cores in the policy.
|
||
|
||
.. _power_man_requests:
|
||
|
||
JSON Interface for Power Management Requests and Policies
|
||
---------------------------------------------------------
|
||
|
||
In addition to the command line interface for the host command, and a
|
||
``virtio-serial`` interface for VM power policies, there is also a JSON
|
||
interface through which power commands and policies can be sent.
|
||
|
||
**Note**: This functionality adds a dependency on the Jansson library.
|
||
Install the Jansson development package on the system to avail of the
|
||
JSON parsing functionality in the app. Issue the ``apt-get install
|
||
libjansson-dev`` command to install the development package. The command
|
||
and package name may be different depending on your operating system. It
|
||
is worth noting that the app builds successfully if this package is not
|
||
present, but a warning displays during compilation, and the JSON parsing
|
||
functionality is not present in the app.
|
||
|
||
Send a request or policy to the VM Power Manager by simply opening a
|
||
fifo file at ``/tmp/powermonitor/fifo``, writing a JSON string to that file,
|
||
and closing the file.
|
||
|
||
The JSON string can be a power management request or a policy, and takes
|
||
the following format:
|
||
|
||
.. code-block:: javascript
|
||
|
||
{"packet_type": {
|
||
"pair_1": value,
|
||
"pair_2": value
|
||
}}
|
||
|
||
The ``packet_type`` header can contain one of two values, depending on
|
||
whether a power management request or policy is being sent. The two
|
||
possible values are ``instruction`` and ``policy`` and the expected name-value
|
||
pairs are different depending on which type is sent.
|
||
|
||
The pairs are in the format of standard JSON name-value pairs. The value
|
||
type varies between the different name-value pairs, and may be integers,
|
||
strings, arrays, and so on. See :ref:`json_interface_ex`
|
||
for examples of policies and instructions and
|
||
:ref:`json_name_value_pair` for the supported names and value types.
|
||
|
||
.. _json_interface_ex:
|
||
|
||
JSON Interface Examples
|
||
~~~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
The following is an example JSON string that creates a time-profile
|
||
policy.
|
||
|
||
.. code-block:: JSON
|
||
|
||
{"policy": {
|
||
"name": "ubuntu",
|
||
"command": "create",
|
||
"policy_type": "TIME",
|
||
"busy_hours":[ 17, 18, 19, 20, 21, 22, 23 ],
|
||
"quiet_hours":[ 2, 3, 4, 5, 6 ],
|
||
"core_list":[ 11 ]
|
||
}}
|
||
|
||
The following is an example JSON string that removes the named policy.
|
||
|
||
.. code-block:: JSON
|
||
|
||
{"policy": {
|
||
"name": "ubuntu",
|
||
"command": "destroy",
|
||
}}
|
||
|
||
The following is an example JSON string for a power management request.
|
||
|
||
.. code-block:: JSON
|
||
|
||
{"instruction": {
|
||
"name": "ubuntu",
|
||
"command": "power",
|
||
"unit": "SCALE_MAX",
|
||
"resource_id": 10
|
||
}}
|
||
|
||
To query the available frequences of an lcore, use the query_cpu_freq command.
|
||
Where {core_num} is the lcore to query.
|
||
Before using this command, please enable responses via the set_query command on the host.
|
||
|
||
.. code-block:: console
|
||
|
||
query_cpu_freq {core_num}|all
|
||
|
||
To query the capabilities of an lcore, use the query_cpu_caps command.
|
||
Where {core_num} is the lcore to query.
|
||
Before using this command, please enable responses via the set_query command on the host.
|
||
|
||
.. code-block:: console
|
||
|
||
query_cpu_caps {core_num}|all
|
||
|
||
To start the application and configure the power policy, and send it to the host:
|
||
|
||
.. code-block:: console
|
||
|
||
./build/guest_vm_power_mgr -l 0-3 -n 4 -- --vm-name=ubuntu --policy=BRANCH_RATIO --vcpu-list=2-4
|
||
|
||
Once the VM Power Manager Guest CLI appears, issuing the 'send_policy now' command
|
||
will send the policy to the host:
|
||
|
||
.. code-block:: console
|
||
|
||
send_policy now
|
||
|
||
Once the policy is sent to the host, the host application takes over the power monitoring
|
||
of the specified cores in the policy.
|
||
|
||
.. _json_name_value_pair:
|
||
|
||
JSON Name-value Pairs
|
||
~~~~~~~~~~~~~~~~~~~~~
|
||
|
||
The following are the name-value pairs supported by the JSON interface:
|
||
|
||
- `avg_packet_thresh`_
|
||
- `busy_hours`_
|
||
- `command`_
|
||
- `core_list`_
|
||
- `mac_list`_
|
||
- `max_packet_thresh`_
|
||
- `name`_
|
||
- `policy_type`_
|
||
- `quiet_hours`_
|
||
- `resource_id`_
|
||
- `unit`_
|
||
- `workload`_
|
||
|
||
avg_packet_thresh
|
||
^^^^^^^^^^^^^^^^^
|
||
|
||
Description
|
||
The threshold below which the frequency is set to the minimum value
|
||
for the TRAFFIC policy.
|
||
If the traffic rate is above this value and below the maximum value,
|
||
the frequency is set to medium.
|
||
Type
|
||
integer
|
||
Values
|
||
The number of packets below which the TRAFFIC policy applies
|
||
the minimum frequency, or the medium frequency
|
||
if between the average and maximum thresholds.
|
||
Required
|
||
Yes
|
||
Example
|
||
``"avg_packet_thresh": 100000``
|
||
|
||
busy_hours
|
||
^^^^^^^^^^
|
||
|
||
Description
|
||
The hours of the day in which we scale up the cores for busy times.
|
||
Type
|
||
array of integers
|
||
Values
|
||
An array with a list of hour values (0-23).
|
||
Required
|
||
For the TIME policy only.
|
||
Example
|
||
``"busy_hours":[ 17, 18, 19, 20, 21, 22, 23 ]``
|
||
|
||
command
|
||
^^^^^^^
|
||
|
||
Description
|
||
The type of packet to send to the VM Power Manager.
|
||
It is possible to create or destroy a policy or send a direct command
|
||
to adjust the frequency of a core,
|
||
as is possible on the command line interface.
|
||
Type
|
||
string
|
||
Values
|
||
Possible values are:
|
||
- CREATE: Create a new policy.
|
||
- DESTROY: Remove an existing policy.
|
||
- POWER: Send an immediate command, max, min, and so on.
|
||
Required
|
||
Yes
|
||
Example
|
||
``"command": "CREATE"``
|
||
|
||
core_list
|
||
^^^^^^^^^
|
||
|
||
Description
|
||
The cores to which to apply a policy.
|
||
Type
|
||
array of integers
|
||
Values
|
||
An array with a list of virtual CPUs.
|
||
Required
|
||
For CREATE/DESTROY policy requests only.
|
||
Example
|
||
``"core_list":[ 10, 11 ]``
|
||
|
||
mac_list
|
||
^^^^^^^^
|
||
|
||
Description
|
||
When the policy is of type TRAFFIC,
|
||
it is necessary to specify the MAC addresses that the host must monitor.
|
||
Type
|
||
array of strings
|
||
Values
|
||
An array with a list of MAC address strings.
|
||
Required
|
||
For TRAFFIC policy types only.
|
||
Example
|
||
``"mac_list":[ "de:ad:be:ef:01:01","de:ad:be:ef:01:02" ]``
|
||
|
||
max_packet_thresh
|
||
^^^^^^^^^^^^^^^^^
|
||
|
||
Description
|
||
In a policy of type TRAFFIC,
|
||
the threshold value above which the frequency is set to a maximum.
|
||
Type
|
||
integer
|
||
Values
|
||
The number of packets per interval above which
|
||
the TRAFFIC policy applies the maximum frequency.
|
||
Required
|
||
For the TRAFFIC policy only.
|
||
Example
|
||
``"max_packet_thresh": 500000``
|
||
|
||
name
|
||
^^^^
|
||
|
||
Description
|
||
The name of the VM or host.
|
||
Allows the parser to associate the policy with the relevant VM or host OS.
|
||
Type
|
||
string
|
||
Values
|
||
Any valid string.
|
||
Required
|
||
Yes
|
||
Example
|
||
``"name": "ubuntu2"``
|
||
|
||
policy_type
|
||
^^^^^^^^^^^
|
||
|
||
Description
|
||
The type of policy to apply.
|
||
See the ``--policy`` option description for more information.
|
||
Type
|
||
string
|
||
Values
|
||
Possible values are:
|
||
|
||
- TIME: Time-of-day policy.
|
||
Scale the frequencies of the relevant cores up/down
|
||
depending on busy and quiet hours.
|
||
- TRAFFIC: Use statistics from the NIC and scale up and down accordingly.
|
||
- WORKLOAD: Determine how heavily loaded the cores are
|
||
and scale up and down accordingly.
|
||
- BRANCH_RATIO: An out-of-band policy that looks at the ratio
|
||
between branch hits and misses on a core
|
||
and uses that information to determine how much packet processing
|
||
a core is doing.
|
||
|
||
Required
|
||
For ``CREATE`` and ``DESTROY`` policy requests only.
|
||
Example
|
||
``"policy_type": "TIME"``
|
||
|
||
quiet_hours
|
||
^^^^^^^^^^^
|
||
|
||
Description
|
||
The hours of the day to scale down the cores for quiet times.
|
||
Type
|
||
array of integers
|
||
Values
|
||
An array with a list of hour numbers with values in the range 0 to 23.
|
||
Required
|
||
For the TIME policy only.
|
||
Example
|
||
``"quiet_hours":[ 2, 3, 4, 5, 6 ]``
|
||
|
||
resource_id
|
||
^^^^^^^^^^^
|
||
|
||
Description
|
||
The core to which to apply a power command.
|
||
Type
|
||
integer
|
||
Values
|
||
A valid core ID for the VM or host OS.
|
||
Required
|
||
For the ``POWER`` instruction only.
|
||
Example
|
||
``"resource_id": 10``
|
||
|
||
unit
|
||
^^^^
|
||
|
||
Description
|
||
The type of power operation to apply in the command.
|
||
Type
|
||
string
|
||
Values
|
||
- SCALE_MAX: Scale the frequency of this core to the maximum.
|
||
- SCALE_MIN: Scale the frequency of this core to the minimum.
|
||
- SCALE_UP: Scale up the frequency of this core.
|
||
- SCALE_DOWN: Scale down the frequency of this core.
|
||
- ENABLE_TURBO: Enable Intel® Turbo Boost Technology for this core.
|
||
- DISABLE_TURBO: Disable Intel® Turbo Boost Technology for this core.
|
||
Required
|
||
For the ``POWER`` instruction only.
|
||
Example
|
||
``"unit": "SCALE_MAX"``
|
||
|
||
workload
|
||
^^^^^^^^
|
||
|
||
Description
|
||
In a policy of type WORKLOAD,
|
||
it is necessary to specify how heavy the workload is.
|
||
Type
|
||
string
|
||
Values
|
||
- HIGH: Scale the frequency of this core to maximum.
|
||
- MEDIUM: Scale the frequency of this core to minimum.
|
||
- LOW: Scale up the frequency of this core.
|
||
Required
|
||
For the ``WORKLOAD`` policy only.
|
||
Example
|
||
``"workload": "MEDIUM"``
|