066396fef8
The config options for init and debug driver were replaced by
dynamic log levels.
Fixes: 70e28c612d
("net/liquidio: implement dynamic logging")
Cc: stable@dpdk.org
Signed-off-by: Stephen Hemminger <stephen@networkplumber.org>
Reviewed-by: Ferruh Yigit <ferruh.yigit@intel.com>
197 lines
4.9 KiB
ReStructuredText
197 lines
4.9 KiB
ReStructuredText
.. SPDX-License-Identifier: BSD-3-Clause
|
|
Copyright(c) 2017 Cavium, Inc
|
|
|
|
LiquidIO VF Poll Mode Driver
|
|
============================
|
|
|
|
The LiquidIO VF PMD library (librte_pmd_lio) provides poll mode driver support for
|
|
Cavium LiquidIO® II server adapter VFs. PF management and VF creation can be
|
|
done using kernel driver.
|
|
|
|
More information can be found at `Cavium Official Website
|
|
<http://cavium.com/LiquidIO_Adapters.html>`_.
|
|
|
|
Supported LiquidIO Adapters
|
|
-----------------------------
|
|
|
|
- LiquidIO II CN2350 210SV/225SV
|
|
- LiquidIO II CN2350 210SVPT
|
|
- LiquidIO II CN2360 210SV/225SV
|
|
- LiquidIO II CN2360 210SVPT
|
|
|
|
|
|
Pre-Installation Configuration
|
|
------------------------------
|
|
|
|
The following options can be modified in the ``config`` file.
|
|
Please note that enabling debugging options may affect system performance.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_LIO_PMD`` (default ``y``)
|
|
|
|
Toggle compilation of LiquidIO PMD.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_RX`` (default ``n``)
|
|
|
|
Toggle display of receive fast path run-time messages.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_TX`` (default ``n``)
|
|
|
|
Toggle display of transmit fast path run-time messages.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_MBOX`` (default ``n``)
|
|
|
|
Toggle display of mailbox messages.
|
|
|
|
- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_REGS`` (default ``n``)
|
|
|
|
Toggle display of register reads and writes.
|
|
|
|
|
|
SR-IOV: Prerequisites and Sample Application Notes
|
|
--------------------------------------------------
|
|
|
|
This section provides instructions to configure SR-IOV with Linux OS.
|
|
|
|
#. Verify SR-IOV and ARI capabilities are enabled on the adapter using ``lspci``:
|
|
|
|
.. code-block:: console
|
|
|
|
lspci -s <slot> -vvv
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
[...]
|
|
Capabilities: [148 v1] Alternative Routing-ID Interpretation (ARI)
|
|
[...]
|
|
Capabilities: [178 v1] Single Root I/O Virtualization (SR-IOV)
|
|
[...]
|
|
Kernel driver in use: LiquidIO
|
|
|
|
#. Load the kernel module:
|
|
|
|
.. code-block:: console
|
|
|
|
modprobe liquidio
|
|
|
|
#. Bring up the PF ports:
|
|
|
|
.. code-block:: console
|
|
|
|
ifconfig p4p1 up
|
|
ifconfig p4p2 up
|
|
|
|
#. Change PF MTU if required:
|
|
|
|
.. code-block:: console
|
|
|
|
ifconfig p4p1 mtu 9000
|
|
ifconfig p4p2 mtu 9000
|
|
|
|
#. Create VF device(s):
|
|
|
|
Echo number of VFs to be created into ``"sriov_numvfs"`` sysfs entry
|
|
of the parent PF.
|
|
|
|
.. code-block:: console
|
|
|
|
echo 1 > /sys/bus/pci/devices/0000:03:00.0/sriov_numvfs
|
|
echo 1 > /sys/bus/pci/devices/0000:03:00.1/sriov_numvfs
|
|
|
|
#. Assign VF MAC address:
|
|
|
|
Assign MAC address to the VF using iproute2 utility. The syntax is::
|
|
|
|
ip link set <PF iface> vf <VF id> mac <macaddr>
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
ip link set p4p1 vf 0 mac F2:A8:1B:5E:B4:66
|
|
|
|
#. Assign VF(s) to VM.
|
|
|
|
The VF devices may be passed through to the guest VM using qemu or
|
|
virt-manager or virsh etc.
|
|
|
|
Example qemu guest launch command:
|
|
|
|
.. code-block:: console
|
|
|
|
./qemu-system-x86_64 -name lio-vm -machine accel=kvm \
|
|
-cpu host -m 4096 -smp 4 \
|
|
-drive file=<disk_file>,if=none,id=disk1,format=<type> \
|
|
-device virtio-blk-pci,scsi=off,drive=disk1,id=virtio-disk1,bootindex=1 \
|
|
-device vfio-pci,host=03:00.3 -device vfio-pci,host=03:08.3
|
|
|
|
#. Running testpmd
|
|
|
|
Refer to the document
|
|
:ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>` to run
|
|
``testpmd`` application.
|
|
|
|
.. note::
|
|
|
|
Use ``igb_uio`` instead of ``vfio-pci`` in VM.
|
|
|
|
Example output:
|
|
|
|
.. code-block:: console
|
|
|
|
[...]
|
|
EAL: PCI device 0000:03:00.3 on NUMA socket 0
|
|
EAL: probe driver: 177d:9712 net_liovf
|
|
EAL: using IOMMU type 1 (Type 1)
|
|
PMD: net_liovf[03:00.3]INFO: DEVICE : CN23XX VF
|
|
EAL: PCI device 0000:03:08.3 on NUMA socket 0
|
|
EAL: probe driver: 177d:9712 net_liovf
|
|
PMD: net_liovf[03:08.3]INFO: DEVICE : CN23XX VF
|
|
Interactive-mode selected
|
|
USER1: create a new mbuf pool <mbuf_pool_socket_0>: n=171456, size=2176, socket=0
|
|
Configuring Port 0 (socket 0)
|
|
PMD: net_liovf[03:00.3]INFO: Starting port 0
|
|
Port 0: F2:A8:1B:5E:B4:66
|
|
Configuring Port 1 (socket 0)
|
|
PMD: net_liovf[03:08.3]INFO: Starting port 1
|
|
Port 1: 32:76:CC:EE:56:D7
|
|
Checking link statuses...
|
|
Port 0 Link Up - speed 10000 Mbps - full-duplex
|
|
Port 1 Link Up - speed 10000 Mbps - full-duplex
|
|
Done
|
|
testpmd>
|
|
|
|
#. Enabling VF promiscuous mode
|
|
|
|
One VF per PF can be marked as trusted for promiscuous mode.
|
|
|
|
.. code-block:: console
|
|
|
|
ip link set dev <PF iface> vf <VF id> trust on
|
|
|
|
|
|
Limitations
|
|
-----------
|
|
|
|
VF MTU
|
|
~~~~~~
|
|
|
|
VF MTU is limited by PF MTU. Raise PF value before configuring VF for larger packet size.
|
|
|
|
VLAN offload
|
|
~~~~~~~~~~~~
|
|
|
|
Tx VLAN insertion is not supported and consequently VLAN offload feature is
|
|
marked partial.
|
|
|
|
Ring size
|
|
~~~~~~~~~
|
|
|
|
Number of descriptors for Rx/Tx ring should be in the range 128 to 512.
|
|
|
|
CRC striping
|
|
~~~~~~~~~~~~
|
|
|
|
LiquidIO adapters strip ethernet FCS of every packet coming to the host interface.
|