.. SPDX-License-Identifier: BSD-3-Clause
|
|
Copyright(c) 2010-2016 Intel Corporation.
|
|
|
|
IXGBE Driver
|
|
============
|
|
|
|
Vector PMD for IXGBE
|
|
--------------------
|
|
|
|
Vector PMD uses Intel® SIMD instructions to optimize packet I/O.
|
|
It improves load/store bandwidth efficiency of L1 data cache by using a wider SSE/AVX register 1 (1).
|
|
The wider register gives space to hold multiple packet buffers so as to save instruction number when processing bulk of packets.
|
|
|
|
There is no change to PMD API. The RX/TX handler are the only two entries for vPMD packet I/O.
|
|
They are transparently registered at runtime RX/TX execution if all condition checks pass.
|
|
|
|
1. To date, only an SSE version of IX GBE vPMD is available.
|
|
To ensure that vPMD is in the binary code, ensure that the option CONFIG_RTE_IXGBE_INC_VECTOR=y is in the configure file.
|
|
|
|
Some constraints apply as pre-conditions for specific optimizations on bulk packet transfers.
|
|
The following sections explain RX and TX constraints in the vPMD.
|
|
|
|
RX Constraints
|
|
~~~~~~~~~~~~~~
|
|
|
|
Prerequisites and Pre-conditions
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The following prerequisites apply:
|
|
|
|
* To enable vPMD to work for RX, bulk allocation for Rx must be allowed.
|
|
|
|
Ensure that the following pre-conditions are satisfied:
|
|
|
|
* rxq->rx_free_thresh >= RTE_PMD_IXGBE_RX_MAX_BURST
|
|
|
|
* rxq->rx_free_thresh < rxq->nb_rx_desc
|
|
|
|
* (rxq->nb_rx_desc % rxq->rx_free_thresh) == 0
|
|
|
|
* rxq->nb_rx_desc < (IXGBE_MAX_RING_DESC - RTE_PMD_IXGBE_RX_MAX_BURST)
|
|
|
|
These conditions are checked in the code.
|
|
|
|
Scattered packets are not supported in this mode.
|
|
If an incoming packet is greater than the maximum acceptable length of one "mbuf" data size (by default, the size is 2 KB),
|
|
vPMD for RX would be disabled.
|
|
|
|
By default, IXGBE_MAX_RING_DESC is set to 4096 and RTE_PMD_IXGBE_RX_MAX_BURST is set to 32.
|
|
|
|
Feature not Supported by RX Vector PMD
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
Some features are not supported when trying to increase the throughput in vPMD.
|
|
They are:
|
|
|
|
* IEEE1588
|
|
|
|
* FDIR
|
|
|
|
* Header split
|
|
|
|
* RX checksum off load
|
|
|
|
Other features are supported using optional MACRO configuration. They include:
|
|
|
|
* HW VLAN strip
|
|
|
|
* HW extend dual VLAN
|
|
|
|
To guarantee the constraint, capabilities in dev_conf.rxmode.offloads will be checked:
|
|
|
|
* DEV_RX_OFFLOAD_VLAN_STRIP
|
|
|
|
* DEV_RX_OFFLOAD_VLAN_EXTEND
|
|
|
|
* DEV_RX_OFFLOAD_CHECKSUM
|
|
|
|
* DEV_RX_OFFLOAD_HEADER_SPLIT
|
|
|
|
* dev_conf
|
|
|
|
fdir_conf->mode will also be checked.
|
|
|
|
RX Burst Size
|
|
^^^^^^^^^^^^^
|
|
|
|
As vPMD is focused on high throughput, it assumes that the RX burst size is equal to or greater than 32 per burst.
|
|
It returns zero if using nb_pkt < 32 as the expected packet number in the receive handler.
|
|
|
|
TX Constraint
|
|
~~~~~~~~~~~~~
|
|
|
|
Prerequisite
|
|
^^^^^^^^^^^^
|
|
|
|
The only prerequisite is related to tx_rs_thresh.
|
|
The tx_rs_thresh value must be greater than or equal to RTE_PMD_IXGBE_TX_MAX_BURST,
|
|
but less or equal to RTE_IXGBE_TX_MAX_FREE_BUF_SZ.
|
|
Consequently, by default the tx_rs_thresh value is in the range 32 to 64.
|
|
|
|
Feature not Supported by TX Vector PMD
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
TX vPMD only works when offloads is set to 0
|
|
|
|
This means that it does not support any TX offload.
|
|
|
|
Application Programming Interface
|
|
---------------------------------
|
|
|
|
In DPDK release v16.11 an API for ixgbe specific functions has been added to the ixgbe PMD.
|
|
The declarations for the API functions are in the header ``rte_pmd_ixgbe.h``.
|
|
|
|
Sample Application Notes
|
|
------------------------
|
|
|
|
l3fwd
|
|
~~~~~
|
|
|
|
When running l3fwd with vPMD, there is one thing to note.
|
|
In the configuration, ensure that DEV_RX_OFFLOAD_CHECKSUM in port_conf.rxmode.offloads is NOT set.
|
|
Otherwise, by default, RX vPMD is disabled.
|
|
|
|
load_balancer
|
|
~~~~~~~~~~~~~
|
|
|
|
As in the case of l3fwd, to enable vPMD, do NOT set DEV_RX_OFFLOAD_CHECKSUM in port_conf.rxmode.offloads.
|
|
In addition, for improved performance, use -bsz "(32,32),(64,64),(32,32)" in load_balancer to avoid using the default burst size of 144.
|
|
|
|
|
|
Limitations or Known issues
|
|
---------------------------
|
|
|
|
Malicious Driver Detection not Supported
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The Intel x550 series NICs support a feature called MDD (Malicious
|
|
Driver Detection) which checks the behavior of the VF driver.
|
|
If this feature is enabled, the VF must use the advanced context descriptor
|
|
correctly and set the CC (Check Context) bit.
|
|
DPDK PF doesn't support MDD, but kernel PF does. We may hit problem in this
|
|
scenario kernel PF + DPDK VF. If user enables MDD in kernel PF, DPDK VF will
|
|
not work. Because kernel PF thinks the VF is malicious. But actually it's not.
|
|
The only reason is the VF doesn't act as MDD required.
|
|
There's significant performance impact to support MDD. DPDK should check if
|
|
the advanced context descriptor should be set and set it. And DPDK has to ask
|
|
the info about the header length from the upper layer, because parsing the
|
|
packet itself is not acceptable. So, it's too expensive to support MDD.
|
|
When using kernel PF + DPDK VF on x550, please make sure to use a kernel
|
|
PF driver that disables MDD or can disable MDD.
|
|
|
|
Some kernel drivers already disable MDD by default while some kernels can use
|
|
the command ``insmod ixgbe.ko MDD=0,0`` to disable MDD. Each "0" in the
|
|
command refers to a port. For example, if there are 6 ixgbe ports, the command
|
|
should be changed to ``insmod ixgbe.ko MDD=0,0,0,0,0,0``.
|
|
|
|
|
|
Statistics
|
|
~~~~~~~~~~
|
|
|
|
The statistics of ixgbe hardware must be polled regularly in order for it to
|
|
remain consistent. Running a DPDK application without polling the statistics will
|
|
cause registers on hardware to count to the maximum value, and "stick" at
|
|
that value.
|
|
|
|
In order to avoid statistic registers every reaching the maximum value,
|
|
read the statistics from the hardware using ``rte_eth_stats_get()`` or
|
|
``rte_eth_xstats_get()``.
|
|
|
|
The maximum time between statistics polls that ensures consistent results can
|
|
be calculated as follows:
|
|
|
|
.. code-block:: c
|
|
|
|
max_read_interval = UINT_MAX / max_packets_per_second
|
|
max_read_interval = 4294967295 / 14880952
|
|
max_read_interval = 288.6218096127183 (seconds)
|
|
max_read_interval = ~4 mins 48 sec.
|
|
|
|
In order to ensure valid results, it is recommended to poll every 4 minutes.
|
|
|
|
MTU setting
|
|
~~~~~~~~~~~
|
|
|
|
Although the user can set the MTU separately on PF and VF ports, the ixgbe NIC
|
|
only supports one global MTU per physical port.
|
|
So when the user sets different MTUs on PF and VF ports in one physical port,
|
|
the real MTU for all these PF and VF ports is the largest value set.
|
|
This behavior is based on the kernel driver behavior.
|
|
|
|
VF MAC address setting
|
|
~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
On ixgbe, the concept of "pool" can be used for different things depending on
|
|
the mode. In VMDq mode, "pool" means a VMDq pool. In IOV mode, "pool" means a
|
|
VF.
|
|
|
|
There is no RTE API to add a VF's MAC address from the PF. On ixgbe, the
|
|
``rte_eth_dev_mac_addr_add()`` function can be used to add a VF's MAC address,
|
|
as a workaround.
|
|
|
|
|
|
Inline crypto processing support
|
|
--------------------------------
|
|
|
|
Inline IPsec processing is supported for ``RTE_SECURITY_ACTION_TYPE_INLINE_CRYPTO``
|
|
mode for ESP packets only:
|
|
|
|
- ESP authentication only: AES-128-GMAC (128-bit key)
|
|
- ESP encryption and authentication: AES-128-GCM (128-bit key)
|
|
|
|
IPsec Security Gateway Sample Application supports inline IPsec processing for
|
|
ixgbe PMD.
|
|
|
|
For more details see the IPsec Security Gateway Sample Application and Security
|
|
library documentation.
|
|
|
|
|
|
Virtual Function Port Representors
|
|
----------------------------------
|
|
The IXGBE PF PMD supports the creation of VF port representors for the control
|
|
and monitoring of IXGBE virtual function devices. Each port representor
|
|
corresponds to a single virtual function of that device. Using the ``devargs``
|
|
option ``representor`` the user can specify which virtual functions to create
|
|
port representors for on initialization of the PF PMD by passing the VF IDs of
|
|
the VFs which are required.::
|
|
|
|
-w DBDF,representor=[0,1,4]
|
|
|
|
Currently hot-plugging of representor ports is not supported so all required
|
|
representors must be specified on the creation of the PF.
|
|
|
|
Supported Chipsets and NICs
|
|
---------------------------
|
|
|
|
- Intel 82599EB 10 Gigabit Ethernet Controller
|
|
- Intel 82598EB 10 Gigabit Ethernet Controller
|
|
- Intel 82599ES 10 Gigabit Ethernet Controller
|
|
- Intel 82599EN 10 Gigabit Ethernet Controller
|
|
- Intel Ethernet Controller X540-AT2
|
|
- Intel Ethernet Controller X550-BT2
|
|
- Intel Ethernet Controller X550-AT2
|
|
- Intel Ethernet Controller X550-AT
|
|
- Intel Ethernet Converged Network Adapter X520-SR1
|
|
- Intel Ethernet Converged Network Adapter X520-SR2
|
|
- Intel Ethernet Converged Network Adapter X520-LR1
|
|
- Intel Ethernet Converged Network Adapter X520-DA1
|
|
- Intel Ethernet Converged Network Adapter X520-DA2
|
|
- Intel Ethernet Converged Network Adapter X520-DA4
|
|
- Intel Ethernet Converged Network Adapter X520-QDA1
|
|
- Intel Ethernet Converged Network Adapter X520-T2
|
|
- Intel 10 Gigabit AF DA Dual Port Server Adapter
|
|
- Intel 10 Gigabit AT Server Adapter
|
|
- Intel 10 Gigabit AT2 Server Adapter
|
|
- Intel 10 Gigabit CX4 Dual Port Server Adapter
|
|
- Intel 10 Gigabit XF LR Server Adapter
|
|
- Intel 10 Gigabit XF SR Dual Port Server Adapter
|
|
- Intel 10 Gigabit XF SR Server Adapter
|
|
- Intel Ethernet Converged Network Adapter X540-T1
|
|
- Intel Ethernet Converged Network Adapter X540-T2
|
|
- Intel Ethernet Converged Network Adapter X550-T1
|
|
- Intel Ethernet Converged Network Adapter X550-T2
|