edcdb3c5f7
Several customers have reported a link flap issue on 82579. The symptoms are random and intermittent link losses when 82579 is connected to specific switches. Issue has been root caused as interoperability problem between the NIC and at least some Broadcom PHYs in the Energy Efficient Ethernet wake mechanism. To fix the issue, we are disabling the Phase Locked Loop shutdown in 100M Low Power Idle. This solution will cause an increase of power in 100M EEE link. It may cost additional 28mW in this specific mode. Signed-off-by: Wenzhuo Lu <wenzhuo.lu@intel.com> |
||
---|---|---|
.. | ||
base | ||
e1000_ethdev.h | ||
e1000_logs.h | ||
em_ethdev.c | ||
em_rxtx.c | ||
igb_ethdev.c | ||
igb_pf.c | ||
igb_regs.h | ||
igb_rxtx.c | ||
Makefile | ||
rte_pmd_e1000_version.map |