68d99d00ae
Make is no longer supported for compiling DPDK, references are now removed in the documentation. Signed-off-by: Ciara Power <ciara.power@intel.com> Reviewed-by: Bruce Richardson <bruce.richardson@intel.com> Reviewed-by: Igor Russkikh <irusskikh@marvell.com> Reviewed-by: Ferruh Yigit <ferruh.yigit@intel.com> Reviewed-by: Harman Kalra <hkalra@marvell.com> Acked-by: Ajit Khaparde <ajit.khaparde@broadcom.com> Acked-by: Hyong Youb Kim <hyonkim@cisco.com>
609 lines
26 KiB
ReStructuredText
609 lines
26 KiB
ReStructuredText
.. SPDX-License-Identifier: BSD-3-Clause
|
|
Copyright(c) 2010-2014 Intel Corporation.
|
|
|
|
Intel Virtual Function Driver
|
|
=============================
|
|
|
|
Supported Intel® Ethernet Controllers (see the *DPDK Release Notes* for details)
|
|
support the following modes of operation in a virtualized environment:
|
|
|
|
* **SR-IOV mode**: Involves direct assignment of part of the port resources to different guest operating systems
|
|
using the PCI-SIG Single Root I/O Virtualization (SR IOV) standard,
|
|
also known as "native mode" or "pass-through" mode.
|
|
In this chapter, this mode is referred to as IOV mode.
|
|
|
|
* **VMDq mode**: Involves central management of the networking resources by an IO Virtual Machine (IOVM) or
|
|
a Virtual Machine Monitor (VMM), also known as software switch acceleration mode.
|
|
In this chapter, this mode is referred to as the Next Generation VMDq mode.
|
|
|
|
SR-IOV Mode Utilization in a DPDK Environment
|
|
---------------------------------------------
|
|
|
|
The DPDK uses the SR-IOV feature for hardware-based I/O sharing in IOV mode.
|
|
Therefore, it is possible to partition SR-IOV capability on Ethernet controller NIC resources logically and
|
|
expose them to a virtual machine as a separate PCI function called a "Virtual Function".
|
|
Refer to :numref:`figure_single_port_nic`.
|
|
|
|
Therefore, a NIC is logically distributed among multiple virtual machines (as shown in :numref:`figure_single_port_nic`),
|
|
while still having global data in common to share with the Physical Function and other Virtual Functions.
|
|
The DPDK fm10kvf, i40evf, igbvf or ixgbevf as a Poll Mode Driver (PMD) serves for the Intel® 82576 Gigabit Ethernet Controller,
|
|
Intel® Ethernet Controller I350 family, Intel® 82599 10 Gigabit Ethernet Controller NIC,
|
|
Intel® Fortville 10/40 Gigabit Ethernet Controller NIC's virtual PCI function, or PCIe host-interface of the Intel Ethernet Switch
|
|
FM10000 Series.
|
|
Meanwhile the DPDK Poll Mode Driver (PMD) also supports "Physical Function" of such NIC's on the host.
|
|
|
|
The DPDK PF/VF Poll Mode Driver (PMD) supports the Layer 2 switch on Intel® 82576 Gigabit Ethernet Controller,
|
|
Intel® Ethernet Controller I350 family, Intel® 82599 10 Gigabit Ethernet Controller,
|
|
and Intel® Fortville 10/40 Gigabit Ethernet Controller NICs so that guest can choose it for inter virtual machine traffic in SR-IOV mode.
|
|
|
|
For more detail on SR-IOV, please refer to the following documents:
|
|
|
|
* `SR-IOV provides hardware based I/O sharing <http://www.intel.com/network/connectivity/solutions/vmdc.htm>`_
|
|
|
|
* `PCI-SIG-Single Root I/O Virtualization Support on IA
|
|
<http://www.intel.com/content/www/us/en/pci-express/pci-sig-single-root-io-virtualization-support-in-virtualization-technology-for-connectivity-paper.html>`_
|
|
|
|
* `Scalable I/O Virtualized Servers <http://www.intel.com/content/www/us/en/virtualization/server-virtualization/scalable-i-o-virtualized-servers-paper.html>`_
|
|
|
|
.. _figure_single_port_nic:
|
|
|
|
.. figure:: img/single_port_nic.*
|
|
|
|
Virtualization for a Single Port NIC in SR-IOV Mode
|
|
|
|
|
|
Physical and Virtual Function Infrastructure
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The following describes the Physical Function and Virtual Functions infrastructure for the supported Ethernet Controller NICs.
|
|
|
|
Virtual Functions operate under the respective Physical Function on the same NIC Port and therefore have no access
|
|
to the global NIC resources that are shared between other functions for the same NIC port.
|
|
|
|
A Virtual Function has basic access to the queue resources and control structures of the queues assigned to it.
|
|
For global resource access, a Virtual Function has to send a request to the Physical Function for that port,
|
|
and the Physical Function operates on the global resources on behalf of the Virtual Function.
|
|
For this out-of-band communication, an SR-IOV enabled NIC provides a memory buffer for each Virtual Function,
|
|
which is called a "Mailbox".
|
|
|
|
Intel® Ethernet Adaptive Virtual Function
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
Adaptive Virtual Function (IAVF) is a SR-IOV Virtual Function with the same device id (8086:1889) on different Intel Ethernet Controller.
|
|
IAVF Driver is VF driver which supports for all future Intel devices without requiring a VM update. And since this happens to be an adaptive VF driver,
|
|
every new drop of the VF driver would add more and more advanced features that can be turned on in the VM if the underlying HW device supports those
|
|
advanced features based on a device agnostic way without ever compromising on the base functionality. IAVF provides generic hardware interface and
|
|
interface between IAVF driver and a compliant PF driver is specified.
|
|
|
|
Intel products starting Ethernet Controller 700 Series to support Adaptive Virtual Function.
|
|
|
|
The way to generate Virtual Function is like normal, and the resource of VF assignment depends on the NIC Infrastructure.
|
|
|
|
For more detail on SR-IOV, please refer to the following documents:
|
|
|
|
* `Intel® IAVF HAS <https://www.intel.com/content/dam/www/public/us/en/documents/product-specifications/ethernet-adaptive-virtual-function-hardware-spec.pdf>`_
|
|
|
|
.. note::
|
|
|
|
To use DPDK IAVF PMD on Intel® 700 Series Ethernet Controller, the device id (0x1889) need to specified during device
|
|
assignment in hypervisor. Take qemu for example, the device assignment should carry the IAVF device id (0x1889) like
|
|
``-device vfio-pci,x-pci-device-id=0x1889,host=03:0a.0``.
|
|
|
|
The PCIE host-interface of Intel Ethernet Switch FM10000 Series VF infrastructure
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
In a virtualized environment, the programmer can enable a maximum of *64 Virtual Functions (VF)*
|
|
globally per PCIE host-interface of the Intel Ethernet Switch FM10000 Series device.
|
|
Each VF can have a maximum of 16 queue pairs.
|
|
The Physical Function in host could be only configured by the Linux* fm10k driver
|
|
(in the case of the Linux Kernel-based Virtual Machine [KVM]), DPDK PMD PF driver doesn't support it yet.
|
|
|
|
For example,
|
|
|
|
* Using Linux* fm10k driver:
|
|
|
|
.. code-block:: console
|
|
|
|
rmmod fm10k (To remove the fm10k module)
|
|
insmod fm0k.ko max_vfs=2,2 (To enable two Virtual Functions per port)
|
|
|
|
Virtual Function enumeration is performed in the following sequence by the Linux* pci driver for a dual-port NIC.
|
|
When you enable the four Virtual Functions with the above command, the four enabled functions have a Function#
|
|
represented by (Bus#, Device#, Function#) in sequence starting from 0 to 3.
|
|
However:
|
|
|
|
* Virtual Functions 0 and 2 belong to Physical Function 0
|
|
|
|
* Virtual Functions 1 and 3 belong to Physical Function 1
|
|
|
|
.. note::
|
|
|
|
The above is an important consideration to take into account when targeting specific packets to a selected port.
|
|
|
|
Intel® X710/XL710 Gigabit Ethernet Controller VF Infrastructure
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
In a virtualized environment, the programmer can enable a maximum of *128 Virtual Functions (VF)*
|
|
globally per Intel® X710/XL710 Gigabit Ethernet Controller NIC device.
|
|
The Physical Function in host could be either configured by the Linux* i40e driver
|
|
(in the case of the Linux Kernel-based Virtual Machine [KVM]) or by DPDK PMD PF driver.
|
|
When using both DPDK PMD PF/VF drivers, the whole NIC will be taken over by DPDK based application.
|
|
|
|
For example,
|
|
|
|
* Using Linux* i40e driver:
|
|
|
|
.. code-block:: console
|
|
|
|
rmmod i40e (To remove the i40e module)
|
|
insmod i40e.ko max_vfs=2,2 (To enable two Virtual Functions per port)
|
|
|
|
* Using the DPDK PMD PF i40e driver:
|
|
|
|
Kernel Params: iommu=pt, intel_iommu=on
|
|
|
|
.. code-block:: console
|
|
|
|
modprobe uio
|
|
insmod igb_uio
|
|
./dpdk-devbind.py -b igb_uio bb:ss.f
|
|
echo 2 > /sys/bus/pci/devices/0000\:bb\:ss.f/max_vfs (To enable two VFs on a specific PCI device)
|
|
|
|
Launch the DPDK testpmd/example or your own host daemon application using the DPDK PMD library.
|
|
|
|
Virtual Function enumeration is performed in the following sequence by the Linux* pci driver for a dual-port NIC.
|
|
When you enable the four Virtual Functions with the above command, the four enabled functions have a Function#
|
|
represented by (Bus#, Device#, Function#) in sequence starting from 0 to 3.
|
|
However:
|
|
|
|
* Virtual Functions 0 and 2 belong to Physical Function 0
|
|
|
|
* Virtual Functions 1 and 3 belong to Physical Function 1
|
|
|
|
.. note::
|
|
|
|
The above is an important consideration to take into account when targeting specific packets to a selected port.
|
|
|
|
For Intel® X710/XL710 Gigabit Ethernet Controller, queues are in pairs. One queue pair means one receive queue and
|
|
one transmit queue. The default number of queue pairs per VF is 4, and can be 16 in maximum.
|
|
|
|
Intel® 82599 10 Gigabit Ethernet Controller VF Infrastructure
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
The programmer can enable a maximum of *63 Virtual Functions* and there must be *one Physical Function* per Intel® 82599
|
|
10 Gigabit Ethernet Controller NIC port.
|
|
The reason for this is that the device allows for a maximum of 128 queues per port and a virtual/physical function has to
|
|
have at least one queue pair (RX/TX).
|
|
The current implementation of the DPDK ixgbevf driver supports a single queue pair (RX/TX) per Virtual Function.
|
|
The Physical Function in host could be either configured by the Linux* ixgbe driver
|
|
(in the case of the Linux Kernel-based Virtual Machine [KVM]) or by DPDK PMD PF driver.
|
|
When using both DPDK PMD PF/VF drivers, the whole NIC will be taken over by DPDK based application.
|
|
|
|
For example,
|
|
|
|
* Using Linux* ixgbe driver:
|
|
|
|
.. code-block:: console
|
|
|
|
rmmod ixgbe (To remove the ixgbe module)
|
|
insmod ixgbe max_vfs=2,2 (To enable two Virtual Functions per port)
|
|
|
|
* Using the DPDK PMD PF ixgbe driver:
|
|
|
|
Kernel Params: iommu=pt, intel_iommu=on
|
|
|
|
.. code-block:: console
|
|
|
|
modprobe uio
|
|
insmod igb_uio
|
|
./dpdk-devbind.py -b igb_uio bb:ss.f
|
|
echo 2 > /sys/bus/pci/devices/0000\:bb\:ss.f/max_vfs (To enable two VFs on a specific PCI device)
|
|
|
|
Launch the DPDK testpmd/example or your own host daemon application using the DPDK PMD library.
|
|
|
|
* Using the DPDK PMD PF ixgbe driver to enable VF RSS:
|
|
|
|
Same steps as above to install the modules of uio, igb_uio, specify max_vfs for PCI device, and
|
|
launch the DPDK testpmd/example or your own host daemon application using the DPDK PMD library.
|
|
|
|
The available queue number (at most 4) per VF depends on the total number of pool, which is
|
|
determined by the max number of VF at PF initialization stage and the number of queue specified
|
|
in config:
|
|
|
|
* If the max number of VFs (max_vfs) is set in the range of 1 to 32:
|
|
|
|
If the number of Rx queues is specified as 4 (``--rxq=4`` in testpmd), then there are totally 32
|
|
pools (ETH_32_POOLS), and each VF could have 4 Rx queues;
|
|
|
|
If the number of Rx queues is specified as 2 (``--rxq=2`` in testpmd), then there are totally 32
|
|
pools (ETH_32_POOLS), and each VF could have 2 Rx queues;
|
|
|
|
* If the max number of VFs (max_vfs) is in the range of 33 to 64:
|
|
|
|
If the number of Rx queues in specified as 4 (``--rxq=4`` in testpmd), then error message is expected
|
|
as ``rxq`` is not correct at this case;
|
|
|
|
If the number of rxq is 2 (``--rxq=2`` in testpmd), then there is totally 64 pools (ETH_64_POOLS),
|
|
and each VF have 2 Rx queues;
|
|
|
|
On host, to enable VF RSS functionality, rx mq mode should be set as ETH_MQ_RX_VMDQ_RSS
|
|
or ETH_MQ_RX_RSS mode, and SRIOV mode should be activated (max_vfs >= 1).
|
|
It also needs config VF RSS information like hash function, RSS key, RSS key length.
|
|
|
|
.. note::
|
|
|
|
The limitation for VF RSS on Intel® 82599 10 Gigabit Ethernet Controller is:
|
|
The hash and key are shared among PF and all VF, the RETA table with 128 entries is also shared
|
|
among PF and all VF; So it could not to provide a method to query the hash and reta content per
|
|
VF on guest, while, if possible, please query them on host for the shared RETA information.
|
|
|
|
Virtual Function enumeration is performed in the following sequence by the Linux* pci driver for a dual-port NIC.
|
|
When you enable the four Virtual Functions with the above command, the four enabled functions have a Function#
|
|
represented by (Bus#, Device#, Function#) in sequence starting from 0 to 3.
|
|
However:
|
|
|
|
* Virtual Functions 0 and 2 belong to Physical Function 0
|
|
|
|
* Virtual Functions 1 and 3 belong to Physical Function 1
|
|
|
|
.. note::
|
|
|
|
The above is an important consideration to take into account when targeting specific packets to a selected port.
|
|
|
|
Intel® 82576 Gigabit Ethernet Controller and Intel® Ethernet Controller I350 Family VF Infrastructure
|
|
^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
|
|
|
|
In a virtualized environment, an Intel® 82576 Gigabit Ethernet Controller serves up to eight virtual machines (VMs).
|
|
The controller has 16 TX and 16 RX queues.
|
|
They are generally referred to (or thought of) as queue pairs (one TX and one RX queue).
|
|
This gives the controller 16 queue pairs.
|
|
|
|
A pool is a group of queue pairs for assignment to the same VF, used for transmit and receive operations.
|
|
The controller has eight pools, with each pool containing two queue pairs, that is, two TX and two RX queues assigned to each VF.
|
|
|
|
In a virtualized environment, an Intel® Ethernet Controller I350 family device serves up to eight virtual machines (VMs) per port.
|
|
The eight queues can be accessed by eight different VMs if configured correctly (the i350 has 4x1GbE ports each with 8T X and 8 RX queues),
|
|
that means, one Transmit and one Receive queue assigned to each VF.
|
|
|
|
For example,
|
|
|
|
* Using Linux* igb driver:
|
|
|
|
.. code-block:: console
|
|
|
|
rmmod igb (To remove the igb module)
|
|
insmod igb max_vfs=2,2 (To enable two Virtual Functions per port)
|
|
|
|
* Using DPDK PMD PF igb driver:
|
|
|
|
Kernel Params: iommu=pt, intel_iommu=on modprobe uio
|
|
|
|
.. code-block:: console
|
|
|
|
insmod igb_uio
|
|
./dpdk-devbind.py -b igb_uio bb:ss.f
|
|
echo 2 > /sys/bus/pci/devices/0000\:bb\:ss.f/max_vfs (To enable two VFs on a specific pci device)
|
|
|
|
Launch DPDK testpmd/example or your own host daemon application using the DPDK PMD library.
|
|
|
|
Virtual Function enumeration is performed in the following sequence by the Linux* pci driver for a four-port NIC.
|
|
When you enable the four Virtual Functions with the above command, the four enabled functions have a Function#
|
|
represented by (Bus#, Device#, Function#) in sequence, starting from 0 to 7.
|
|
However:
|
|
|
|
* Virtual Functions 0 and 4 belong to Physical Function 0
|
|
|
|
* Virtual Functions 1 and 5 belong to Physical Function 1
|
|
|
|
* Virtual Functions 2 and 6 belong to Physical Function 2
|
|
|
|
* Virtual Functions 3 and 7 belong to Physical Function 3
|
|
|
|
.. note::
|
|
|
|
The above is an important consideration to take into account when targeting specific packets to a selected port.
|
|
|
|
Validated Hypervisors
|
|
~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The validated hypervisor is:
|
|
|
|
* KVM (Kernel Virtual Machine) with Qemu, version 0.14.0
|
|
|
|
However, the hypervisor is bypassed to configure the Virtual Function devices using the Mailbox interface,
|
|
the solution is hypervisor-agnostic.
|
|
Xen* and VMware* (when SR- IOV is supported) will also be able to support the DPDK with Virtual Function driver support.
|
|
|
|
Expected Guest Operating System in Virtual Machine
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
The expected guest operating systems in a virtualized environment are:
|
|
|
|
* Fedora* 14 (64-bit)
|
|
|
|
* Ubuntu* 10.04 (64-bit)
|
|
|
|
For supported kernel versions, refer to the *DPDK Release Notes*.
|
|
|
|
Setting Up a KVM Virtual Machine Monitor
|
|
----------------------------------------
|
|
|
|
The following describes a target environment:
|
|
|
|
* Host Operating System: Fedora 14
|
|
|
|
* Hypervisor: KVM (Kernel Virtual Machine) with Qemu version 0.14.0
|
|
|
|
* Guest Operating System: Fedora 14
|
|
|
|
* Linux Kernel Version: Refer to the *DPDK Getting Started Guide*
|
|
|
|
* Target Applications: l2fwd, l3fwd-vf
|
|
|
|
The setup procedure is as follows:
|
|
|
|
#. Before booting the Host OS, open **BIOS setup** and enable **Intel® VT features**.
|
|
|
|
#. While booting the Host OS kernel, pass the intel_iommu=on kernel command line argument using GRUB.
|
|
When using DPDK PF driver on host, pass the iommu=pt kernel command line argument in GRUB.
|
|
|
|
#. Download qemu-kvm-0.14.0 from
|
|
`http://sourceforge.net/projects/kvm/files/qemu-kvm/ <http://sourceforge.net/projects/kvm/files/qemu-kvm/>`_
|
|
and install it in the Host OS using the following steps:
|
|
|
|
When using a recent kernel (2.6.25+) with kvm modules included:
|
|
|
|
.. code-block:: console
|
|
|
|
tar xzf qemu-kvm-release.tar.gz
|
|
cd qemu-kvm-release
|
|
./configure --prefix=/usr/local/kvm
|
|
make
|
|
sudo make install
|
|
sudo /sbin/modprobe kvm-intel
|
|
|
|
When using an older kernel, or a kernel from a distribution without the kvm modules,
|
|
you must download (from the same link), compile and install the modules yourself:
|
|
|
|
.. code-block:: console
|
|
|
|
tar xjf kvm-kmod-release.tar.bz2
|
|
cd kvm-kmod-release
|
|
./configure
|
|
make
|
|
sudo make install
|
|
sudo /sbin/modprobe kvm-intel
|
|
|
|
qemu-kvm installs in the /usr/local/bin directory.
|
|
|
|
For more details about KVM configuration and usage, please refer to:
|
|
|
|
`http://www.linux-kvm.org/page/HOWTO1 <http://www.linux-kvm.org/page/HOWTO1>`_.
|
|
|
|
#. Create a Virtual Machine and install Fedora 14 on the Virtual Machine.
|
|
This is referred to as the Guest Operating System (Guest OS).
|
|
|
|
#. Download and install the latest ixgbe driver from:
|
|
|
|
`http://downloadcenter.intel.com/Detail_Desc.aspx?agr=Y&DwnldID=14687 <http://downloadcenter.intel.com/Detail_Desc.aspx?agr=Y&DwnldID=14687>`_
|
|
|
|
#. In the Host OS
|
|
|
|
When using Linux kernel ixgbe driver, unload the Linux ixgbe driver and reload it with the max_vfs=2,2 argument:
|
|
|
|
.. code-block:: console
|
|
|
|
rmmod ixgbe
|
|
modprobe ixgbe max_vfs=2,2
|
|
|
|
When using DPDK PMD PF driver, insert DPDK kernel module igb_uio and set the number of VF by sysfs max_vfs:
|
|
|
|
.. code-block:: console
|
|
|
|
modprobe uio
|
|
insmod igb_uio
|
|
./dpdk-devbind.py -b igb_uio 02:00.0 02:00.1 0e:00.0 0e:00.1
|
|
echo 2 > /sys/bus/pci/devices/0000\:02\:00.0/max_vfs
|
|
echo 2 > /sys/bus/pci/devices/0000\:02\:00.1/max_vfs
|
|
echo 2 > /sys/bus/pci/devices/0000\:0e\:00.0/max_vfs
|
|
echo 2 > /sys/bus/pci/devices/0000\:0e\:00.1/max_vfs
|
|
|
|
.. note::
|
|
|
|
You need to explicitly specify number of vfs for each port, for example,
|
|
in the command above, it creates two vfs for the first two ixgbe ports.
|
|
|
|
Let say we have a machine with four physical ixgbe ports:
|
|
|
|
|
|
0000:02:00.0
|
|
|
|
0000:02:00.1
|
|
|
|
0000:0e:00.0
|
|
|
|
0000:0e:00.1
|
|
|
|
The command above creates two vfs for device 0000:02:00.0:
|
|
|
|
.. code-block:: console
|
|
|
|
ls -alrt /sys/bus/pci/devices/0000\:02\:00.0/virt*
|
|
lrwxrwxrwx. 1 root root 0 Apr 13 05:40 /sys/bus/pci/devices/0000:02:00.0/virtfn1 -> ../0000:02:10.2
|
|
lrwxrwxrwx. 1 root root 0 Apr 13 05:40 /sys/bus/pci/devices/0000:02:00.0/virtfn0 -> ../0000:02:10.0
|
|
|
|
It also creates two vfs for device 0000:02:00.1:
|
|
|
|
.. code-block:: console
|
|
|
|
ls -alrt /sys/bus/pci/devices/0000\:02\:00.1/virt*
|
|
lrwxrwxrwx. 1 root root 0 Apr 13 05:51 /sys/bus/pci/devices/0000:02:00.1/virtfn1 -> ../0000:02:10.3
|
|
lrwxrwxrwx. 1 root root 0 Apr 13 05:51 /sys/bus/pci/devices/0000:02:00.1/virtfn0 -> ../0000:02:10.1
|
|
|
|
#. List the PCI devices connected and notice that the Host OS shows two Physical Functions (traditional ports)
|
|
and four Virtual Functions (two for each port).
|
|
This is the result of the previous step.
|
|
|
|
#. Insert the pci_stub module to hold the PCI devices that are freed from the default driver using the following command
|
|
(see http://www.linux-kvm.org/page/How_to_assign_devices_with_VT-d_in_KVM Section 4 for more information):
|
|
|
|
.. code-block:: console
|
|
|
|
sudo /sbin/modprobe pci-stub
|
|
|
|
Unbind the default driver from the PCI devices representing the Virtual Functions.
|
|
A script to perform this action is as follows:
|
|
|
|
.. code-block:: console
|
|
|
|
echo "8086 10ed" > /sys/bus/pci/drivers/pci-stub/new_id
|
|
echo 0000:08:10.0 > /sys/bus/pci/devices/0000:08:10.0/driver/unbind
|
|
echo 0000:08:10.0 > /sys/bus/pci/drivers/pci-stub/bind
|
|
|
|
where, 0000:08:10.0 belongs to the Virtual Function visible in the Host OS.
|
|
|
|
#. Now, start the Virtual Machine by running the following command:
|
|
|
|
.. code-block:: console
|
|
|
|
/usr/local/kvm/bin/qemu-system-x86_64 -m 4096 -smp 4 -boot c -hda lucid.qcow2 -device pci-assign,host=08:10.0
|
|
|
|
where:
|
|
|
|
— -m = memory to assign
|
|
|
|
— -smp = number of smp cores
|
|
|
|
— -boot = boot option
|
|
|
|
— -hda = virtual disk image
|
|
|
|
— -device = device to attach
|
|
|
|
.. note::
|
|
|
|
— The pci-assign,host=08:10.0 value indicates that you want to attach a PCI device
|
|
to a Virtual Machine and the respective (Bus:Device.Function)
|
|
numbers should be passed for the Virtual Function to be attached.
|
|
|
|
— qemu-kvm-0.14.0 allows a maximum of four PCI devices assigned to a VM,
|
|
but this is qemu-kvm version dependent since qemu-kvm-0.14.1 allows a maximum of five PCI devices.
|
|
|
|
— qemu-system-x86_64 also has a -cpu command line option that is used to select the cpu_model
|
|
to emulate in a Virtual Machine. Therefore, it can be used as:
|
|
|
|
.. code-block:: console
|
|
|
|
/usr/local/kvm/bin/qemu-system-x86_64 -cpu ?
|
|
|
|
(to list all available cpu_models)
|
|
|
|
/usr/local/kvm/bin/qemu-system-x86_64 -m 4096 -cpu host -smp 4 -boot c -hda lucid.qcow2 -device pci-assign,host=08:10.0
|
|
|
|
(to use the same cpu_model equivalent to the host cpu)
|
|
|
|
For more information, please refer to: `http://wiki.qemu.org/Features/CPUModels <http://wiki.qemu.org/Features/CPUModels>`_.
|
|
|
|
#. If use vfio-pci to pass through device instead of pci-assign, steps 8 and 9 need to be updated to bind device to vfio-pci and
|
|
replace pci-assign with vfio-pci when start virtual machine.
|
|
|
|
.. code-block:: console
|
|
|
|
sudo /sbin/modprobe vfio-pci
|
|
|
|
echo "8086 10ed" > /sys/bus/pci/drivers/vfio-pci/new_id
|
|
echo 0000:08:10.0 > /sys/bus/pci/devices/0000:08:10.0/driver/unbind
|
|
echo 0000:08:10.0 > /sys/bus/pci/drivers/vfio-pci/bind
|
|
|
|
/usr/local/kvm/bin/qemu-system-x86_64 -m 4096 -smp 4 -boot c -hda lucid.qcow2 -device vfio-pci,host=08:10.0
|
|
|
|
#. Install and run DPDK host app to take over the Physical Function. Eg.
|
|
|
|
.. code-block:: console
|
|
|
|
./<build_dir>/app/dpdk-testpmd -l 0-3 -n 4 -- -i
|
|
|
|
#. Finally, access the Guest OS using vncviewer with the localhost:5900 port and check the lspci command output in the Guest OS.
|
|
The virtual functions will be listed as available for use.
|
|
|
|
#. Configure and install the DPDK on the Guest OS as normal, that is, there is no change to the normal installation procedure.
|
|
|
|
.. note::
|
|
|
|
If you are unable to compile the DPDK and you are getting "error: CPU you selected does not support x86-64 instruction set",
|
|
power off the Guest OS and start the virtual machine with the correct -cpu option in the qemu- system-x86_64 command as shown in step 9.
|
|
You must select the best x86_64 cpu_model to emulate or you can select host option if available.
|
|
|
|
.. note::
|
|
|
|
Run the DPDK l2fwd sample application in the Guest OS with Hugepages enabled.
|
|
For the expected benchmark performance, you must pin the cores from the Guest OS to the Host OS (taskset can be used to do this) and
|
|
you must also look at the PCI Bus layout on the board to ensure you are not running the traffic over the QPI Interface.
|
|
|
|
.. note::
|
|
|
|
* The Virtual Machine Manager (the Fedora package name is virt-manager) is a utility for virtual machine management
|
|
that can also be used to create, start, stop and delete virtual machines.
|
|
If this option is used, step 2 and 6 in the instructions provided will be different.
|
|
|
|
* virsh, a command line utility for virtual machine management,
|
|
can also be used to bind and unbind devices to a virtual machine in Ubuntu.
|
|
If this option is used, step 6 in the instructions provided will be different.
|
|
|
|
* The Virtual Machine Monitor (see :numref:`figure_perf_benchmark`) is equivalent to a Host OS with KVM installed as described in the instructions.
|
|
|
|
.. _figure_perf_benchmark:
|
|
|
|
.. figure:: img/perf_benchmark.*
|
|
|
|
Performance Benchmark Setup
|
|
|
|
|
|
DPDK SR-IOV PMD PF/VF Driver Usage Model
|
|
----------------------------------------
|
|
|
|
Fast Host-based Packet Processing
|
|
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
|
|
Software Defined Network (SDN) trends are demanding fast host-based packet handling.
|
|
In a virtualization environment,
|
|
the DPDK VF PMD driver performs the same throughput result as a non-VT native environment.
|
|
|
|
With such host instance fast packet processing, lots of services such as filtering, QoS,
|
|
DPI can be offloaded on the host fast path.
|
|
|
|
:numref:`figure_fast_pkt_proc` shows the scenario where some VMs directly communicate externally via a VFs,
|
|
while others connect to a virtual switch and share the same uplink bandwidth.
|
|
|
|
.. _figure_fast_pkt_proc:
|
|
|
|
.. figure:: img/fast_pkt_proc.*
|
|
|
|
Fast Host-based Packet Processing
|
|
|
|
|
|
SR-IOV (PF/VF) Approach for Inter-VM Communication
|
|
--------------------------------------------------
|
|
|
|
Inter-VM data communication is one of the traffic bottle necks in virtualization platforms.
|
|
SR-IOV device assignment helps a VM to attach the real device, taking advantage of the bridge in the NIC.
|
|
So VF-to-VF traffic within the same physical port (VM0<->VM1) have hardware acceleration.
|
|
However, when VF crosses physical ports (VM0<->VM2), there is no such hardware bridge.
|
|
In this case, the DPDK PMD PF driver provides host forwarding between such VMs.
|
|
|
|
:numref:`figure_inter_vm_comms` shows an example.
|
|
In this case an update of the MAC address lookup tables in both the NIC and host DPDK application is required.
|
|
|
|
In the NIC, writing the destination of a MAC address belongs to another cross device VM to the PF specific pool.
|
|
So when a packet comes in, its destination MAC address will match and forward to the host DPDK PMD application.
|
|
|
|
In the host DPDK application, the behavior is similar to L2 forwarding,
|
|
that is, the packet is forwarded to the correct PF pool.
|
|
The SR-IOV NIC switch forwards the packet to a specific VM according to the MAC destination address
|
|
which belongs to the destination VF on the VM.
|
|
|
|
.. _figure_inter_vm_comms:
|
|
|
|
.. figure:: img/inter_vm_comms.*
|
|
|
|
Inter-VM Communication
|