nvme/rdma: use trid.adrfam when resolving address
Change-Id: I3c3c0faa808e6047d1f9297dc6985597cc0c4aaf Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
This commit is contained in:
parent
0346dd775e
commit
23fc6682fb
@ -603,12 +603,18 @@ nvme_rdma_connect(struct nvme_rdma_qpair *rqpair)
|
||||
}
|
||||
|
||||
static int
|
||||
nvme_rdma_parse_addr(struct sockaddr_storage *sa, const char *addr, const char *service)
|
||||
nvme_rdma_parse_addr(struct sockaddr_storage *sa, int family, const char *addr, const char *service)
|
||||
{
|
||||
struct addrinfo *res;
|
||||
struct addrinfo hints;
|
||||
int ret;
|
||||
|
||||
ret = getaddrinfo(addr, service, NULL, &res);
|
||||
memset(&hints, 0, sizeof(hints));
|
||||
hints.ai_family = family;
|
||||
hints.ai_socktype = SOCK_STREAM;
|
||||
hints.ai_protocol = 0;
|
||||
|
||||
ret = getaddrinfo(addr, service, &hints, &res);
|
||||
if (ret) {
|
||||
SPDK_ERRLOG("getaddrinfo failed - invalid hostname or IP address\n");
|
||||
return ret;
|
||||
@ -645,6 +651,7 @@ nvme_rdma_qpair_connect(struct nvme_rdma_qpair *rqpair)
|
||||
struct sockaddr_storage sin;
|
||||
int rc;
|
||||
struct spdk_nvme_ctrlr *ctrlr;
|
||||
int family;
|
||||
|
||||
rc = nvmf_cm_construct(rqpair);
|
||||
if (rc < 0) {
|
||||
@ -653,10 +660,25 @@ nvme_rdma_qpair_connect(struct nvme_rdma_qpair *rqpair)
|
||||
}
|
||||
|
||||
ctrlr = rqpair->qpair.ctrlr;
|
||||
|
||||
switch (ctrlr->trid.adrfam) {
|
||||
case SPDK_NVMF_ADRFAM_IPV4:
|
||||
family = AF_INET;
|
||||
break;
|
||||
case SPDK_NVMF_ADRFAM_IPV6:
|
||||
family = AF_INET6;
|
||||
break;
|
||||
default:
|
||||
SPDK_ERRLOG("Unhandled ADRFAM %d\n", ctrlr->trid.adrfam);
|
||||
return -1;
|
||||
}
|
||||
|
||||
SPDK_TRACELOG(SPDK_TRACE_NVME, "adrfam %d ai_family %d\n", ctrlr->trid.adrfam, family);
|
||||
|
||||
memset(&sin, 0, sizeof(struct sockaddr_storage));
|
||||
|
||||
SPDK_TRACELOG(SPDK_TRACE_DEBUG, "trsvcid is %s\n", ctrlr->trid.trsvcid);
|
||||
rc = nvme_rdma_parse_addr(&sin, ctrlr->trid.traddr, ctrlr->trid.trsvcid);
|
||||
rc = nvme_rdma_parse_addr(&sin, family, ctrlr->trid.traddr, ctrlr->trid.trsvcid);
|
||||
if (rc != 0) {
|
||||
SPDK_ERRLOG("nvme_rdma_parse_addr() failed\n");
|
||||
return -1;
|
||||
|
Loading…