test/vhost: Don't use nvmftestinit() in vhost tests
For now this function is not working very well in case it finds E810 cards (we do have some installed across CI pool) as we don't have proper irdma driver in place. Instead, and since it shouldn't be relevant for vhost tests, enable soft-RoCE devices and use them (or any other rdma-capable NIC that ip is going to be allocated on) during the vhost migration tests. Signed-off-by: Michal Berger <michalx.berger@intel.com> Change-Id: I4e8cc7b8eea3ce91684d8a68d0a0e11b8d1e4b9b Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/8750 Reviewed-by: Changpeng Liu <changpeng.liu@intel.com> Reviewed-by: Ziye Yang <ziye.yang@intel.com> Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com> Tested-by: SPDK CI Jenkins <sys_sgci@intel.com> Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
This commit is contained in:
parent
8b19bc2383
commit
5e03beae70
@ -34,7 +34,10 @@ function migration_tc2_cleanup_vhost_config() {
|
||||
function migration_tc2_configure_vhost() {
|
||||
timing_enter migration_tc2_configure_vhost
|
||||
|
||||
TEST_TRANSPORT=rdma TEST_MODE=iso nvmftestinit
|
||||
# Just in case we don't have any rdma-capable NICs on board - using hw or
|
||||
# soft-RoCE during vhost tests should not matter.
|
||||
detect_soft_roce_nics
|
||||
allocate_nic_ips
|
||||
|
||||
# Those are global intentionally - they will be unset in cleanup handler
|
||||
|
||||
@ -57,7 +60,7 @@ function migration_tc2_configure_vhost() {
|
||||
# Override the trap set in place via nvmfappstart()
|
||||
trap 'migration_tc2_error_cleanup; error_exit "${FUNCNAME}" "${LINENO}"' INT ERR EXIT
|
||||
rpc_cmd framework_start_init
|
||||
rpc_cmd nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
|
||||
rpc_cmd nvmf_create_transport -t rdma -u 8192
|
||||
mapfile -t json < <("$rootdir/scripts/gen_nvme.sh")
|
||||
rpc_cmd load_subsystem_config -j "'${json[*]}'"
|
||||
timing_exit start_nvmf_tgt
|
||||
|