bdev/nvme: Don't allow a second identical path for failover
The new path must differ in some way. Change-Id: I98fd2b2cb3220b482efe0a19bfce94ec4e72bec2 Signed-off-by: Ben Walker <benjamin.walker@intel.com> Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9418 Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com> Community-CI: Mellanox Build Bot Tested-by: SPDK CI Jenkins <sys_sgci@intel.com> Reviewed-by: Changpeng Liu <changpeng.liu@intel.com> Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com> Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
This commit is contained in:
parent
a24d549038
commit
e3c398aa1c
@ -275,6 +275,7 @@ rpc_bdev_nvme_attach_controller(struct spdk_jsonrpc_request *request,
|
||||
struct rpc_bdev_nvme_attach_controller_ctx *ctx;
|
||||
struct spdk_nvme_transport_id trid = {};
|
||||
const struct spdk_nvme_ctrlr_opts *opts;
|
||||
const struct spdk_nvme_transport_id *ctrlr_trid;
|
||||
uint32_t prchk_flags = 0;
|
||||
struct nvme_ctrlr *ctrlr = NULL;
|
||||
size_t len, maxlen;
|
||||
@ -399,6 +400,9 @@ rpc_bdev_nvme_attach_controller(struct spdk_jsonrpc_request *request,
|
||||
ctx->req.multipath = strdup("failover");
|
||||
}
|
||||
|
||||
opts = spdk_nvme_ctrlr_get_opts(ctrlr->ctrlr);
|
||||
ctrlr_trid = spdk_nvme_ctrlr_get_transport_id(ctrlr->ctrlr);
|
||||
|
||||
/* This controller already exists. Check what the user wants to do. */
|
||||
if (strcasecmp(ctx->req.multipath, "disable") == 0) {
|
||||
/* The user does not want to do any form of multipathing. */
|
||||
@ -408,6 +412,17 @@ rpc_bdev_nvme_attach_controller(struct spdk_jsonrpc_request *request,
|
||||
goto cleanup;
|
||||
} else if (strcasecmp(ctx->req.multipath, "failover") == 0) {
|
||||
/* The user wants to add this as a failover path. */
|
||||
|
||||
if (strncmp(trid.traddr, ctrlr_trid->traddr, sizeof(trid.traddr)) == 0 &&
|
||||
strncmp(trid.trsvcid, ctrlr_trid->trsvcid, sizeof(trid.trsvcid)) == 0 &&
|
||||
strncmp(ctx->req.opts.src_addr, opts->src_addr, sizeof(opts->src_addr)) == 0 &&
|
||||
strncmp(ctx->req.opts.src_svcid, opts->src_svcid, sizeof(opts->src_svcid)) == 0) {
|
||||
/* Exactly same network path can't be added a second time */
|
||||
spdk_jsonrpc_send_error_response_fmt(request, -EALREADY,
|
||||
"A controller named %s already exists with the specified network path\n",
|
||||
ctx->req.name);
|
||||
goto cleanup;
|
||||
}
|
||||
} else {
|
||||
/* Invalid multipath option */
|
||||
spdk_jsonrpc_send_error_response_fmt(request, -EINVAL,
|
||||
@ -417,16 +432,16 @@ rpc_bdev_nvme_attach_controller(struct spdk_jsonrpc_request *request,
|
||||
}
|
||||
|
||||
if (strncmp(trid.subnqn,
|
||||
spdk_nvme_ctrlr_get_transport_id(ctrlr->ctrlr)->subnqn,
|
||||
ctrlr_trid->subnqn,
|
||||
SPDK_NVMF_NQN_MAX_LEN) != 0) {
|
||||
/* Different SUBNQN is not allowed when specifying the same controller name. */
|
||||
spdk_jsonrpc_send_error_response_fmt(request, -EINVAL,
|
||||
"A controller named %s already exists, but uses a different subnqn (%s)\n",
|
||||
ctx->req.name, spdk_nvme_ctrlr_get_transport_id(ctrlr->ctrlr)->subnqn);
|
||||
ctx->req.name, ctrlr_trid->subnqn);
|
||||
goto cleanup;
|
||||
}
|
||||
|
||||
opts = spdk_nvme_ctrlr_get_opts(ctrlr->ctrlr);
|
||||
|
||||
|
||||
if (strncmp(ctx->req.opts.hostnqn, opts->hostnqn, SPDK_NVMF_NQN_MAX_LEN) != 0) {
|
||||
/* Different HOSTNQN is not allowed when specifying the same controller name. */
|
||||
|
@ -69,6 +69,11 @@ NOT $rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_
|
||||
-s $NVMF_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1 -i $NVMF_FIRST_TARGET_IP -c $NVMF_HOST_FIRST_PORT \
|
||||
-x disable
|
||||
|
||||
# Attempt to add an identical path as a failover path. Should fail.
|
||||
NOT $rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP \
|
||||
-s $NVMF_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1 -i $NVMF_FIRST_TARGET_IP -c $NVMF_HOST_FIRST_PORT \
|
||||
-x failover
|
||||
|
||||
# Add a second path without specifying the host information. Should pass.
|
||||
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP \
|
||||
-s $NVMF_SECOND_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
|
||||
|
Loading…