Commit Graph

490 Commits

Author SHA1 Message Date
jiaqizho
64debe0453 rpc: add a command parser
The changes in the nvmf_create_transport show
how this command parser work. And there have
two benefit for this changed.

1. Simplify the definition of rpc method. no need add
so many args anymore. Also it retains its original
functions, so we can also check the input args.

2. Make the rpc call more versatile, for example.
when user extend the subparsers(add new args
into subparsers), they can pass some private args
into the rpc method by command parser.

Signed-off-by: jiaqizho <jiaqi.zhou@intel.com>
Change-Id: Iaf916e3454f23715cf9216794bb80c65b2b4603f
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6652
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2021-05-11 12:02:00 +00:00
Alexey Marchuk
2fd97e28bf sock: Deprecate enable_zerocopy_send in sock_impl_set_options RPC
This deprecated parameter will be removed in SPDK 21.07

Change-Id: I2b2fbcc798bb50fa6f9dfe35045f66e41c1ceaa9
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7608
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-04-27 08:13:32 +00:00
Alexey Marchuk
8e85b675fc sock: Add new params to configure zcopy for server, client sockets
When zcero copy send is enabled and used by initiator,
it could significantly increase latency in some payloads.
To enable more fine graing configuration of zero copy
send feature, add new parameters enable_zerocopy_send_server
and enable_zerocopy_send_client to spdk_sock_impl_opts to
enable/disable zcopy for specific type of sockets.
Exisiting enable_zerocopy_send parameter affects all types
of sockets.

Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Change-Id: I111c75608f8826980a56e210c076ab8ff16ddbdc
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7457
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-04-27 08:13:32 +00:00
Jin Yu
2f600ca75e virtio-blk: add hotplug rpc
Change-Id: I4ed583d91ae9e820be1ee6f4553f29d6650c4922
Signed-off-by: Jin Yu <jin.yu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5791
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2021-04-16 19:21:13 +00:00
Alexey Marchuk
5c33437b99 bdev_nvme: Add RPC to dump transport statistics
The new RPC bdev_nvme_get_transport_statistics is added.

Change-Id: Ic13d096717c041fd3e0b77eaebca6ae09239698b
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6303
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2021-04-13 21:30:52 +00:00
Rafal Stefanowski
5bdaec6322 ocf/rpc: Add bdev_ocf_set_cache_mode method
This method allows to dynamically switch cache mode on OCF bdev

Signed-off-by: Rafal Stefanowski <rafal.stefanowski@intel.com>
Change-Id: I933273e35bb9f29528657f8f6800c6b52dde32e5
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6547
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-03-18 14:39:09 +00:00
Richael Zhuang
201aa63471 sock: introduce SO_INCOMING_CPU to get placement_id
Leverage SO_INCOMING_CPU to get the CPU affinity of connections
(sockets). And allocate the connections to specific poll groups,
which aims to utilize cache locality.

From our test:
6 P4600 NVMe on target,target uses 8 cores, NIC irqs are bound to
these 8 cores, and initiator side uses 24 and 32 cores,
we can get 11%~17% randwrite performance boost for posix, and 8%~12%
for uring.

Change-Id: I011e0a21502c85adcccd4a14fbe9838b43f54976
Signed-off-by: Richael Zhuang <richael.zhuang@arm.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5748
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-03-09 08:53:52 +00:00
Jim Harris
9713bfe90d rpc.py: print better message if cannot connect
We need to catch the JSONRPCException when we cannot
connect, so that the error message can be printed
more cleanly. Also suggest to the user that maybe
they don't have an SPDK application running when
it cannot connect.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I497bed86573d5bf07a2b48b3d6682a2427aa4987
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6754
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Monica Kenguva <monica.kenguva@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2021-03-09 08:53:36 +00:00
Monica Kenguva
97ef870100 nvmf/rdma: add RPC parameter to specify CQ size with RDMA transport
nvmf_create_transport rpc parameter to configure the CQ size helps
if the user is aware of CQ size needed as iWARP doesn't support CQ resize.

Fixes issue #1747

Signed-off-by: Monica Kenguva <monica.kenguva@intel.com>
Change-Id: Ia9ba2b5f612993be27ebfa3455fb4fefd80ae738
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6495
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2021-03-04 08:14:57 +00:00
Shuhei Matsumoto
20f1cf632b bdev/ocssd: Remove range parameter from bdev_ocssd_create RPC
It has been confirmed that there is no affected use case in
the SPDK community when we remove the range parameter from
the bdev_ocssd_create RPC.

Hence, remove the range parameter from the bdev_ocssd_create RPC,
remove range parameter from bdev_ocssd_create_bdev(), remove range
info from ocssd_bdev_config_json(), and then update unit tests
accordingly.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I1b0a541b61bf26732fd028dc43becb7ca2384f8e
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6220
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2021-02-19 11:28:53 +00:00
Alexey Marchuk
05aeb9db27 bdev/nvme/rpc: Add params to enable TCP hdgst and ddgst
Function bdev_nvme_create accpets new parameter - ctrlr
opts which is passed and filled by RPC handler. That
will allow us to add config parameters for other ctrlr
options with minimal changes.

Change-Id: I96ac1b21e7a3816c652765cddade75423eb843ca
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6023
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: <dongx.yi@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2021-02-09 11:26:51 +00:00
Krzysztof Karas
abf52d7d7f spdk_top: add rpc for scheduler and governor
Added rpc to get name and period of currently set spdk scheduler
and name of currently set spdk governor.

Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Change-Id: I5562a81a7f9e4879bd48a765c9467f70b43f73ab
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5917
Community-CI: Broadcom CI
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Maciej Szwed <maciej.szwed@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2021-01-22 18:33:13 +00:00
Jin Yu
d0657f3230 bdev_null: add null bdev resize rpc
Usually null bdev is used in testing.
The resize function provides flexibility

Change-Id: I603db0b85ff13a86d38ccc8dd6f260807393df93
Signed-off-by: Jin Yu <jin.yu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5797
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-01-18 13:03:02 +00:00
Karol Latecki
df2c932e09 scripts/rpc: fix framework_set_schedule period parameter
Period parameter is marked as optional in rpc.py. This works
as long the rpc call is issued with rpc.py, as argparse
sets period to "None" by default. This patch makes it
an optional argument as well directly in app.py.

Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Change-Id: I2e3cae6df7edd7fc6e1120ee3d4a2655dc60813a
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5942
Reviewed-by: Michal Berger <michalx.berger@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
2021-01-18 08:17:28 +00:00
Jin Yu
2969c5ab30 vhost-blk: recover ring base when reconnect
This patch is for packed ring and recover the ring
base when vhost target reconnect to QEMU.

Change-Id: I73f791b4a55adf9834112afd7dd7bb26c75a135d
Signed-off-by: Jin Yu <jin.yu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4128
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2021-01-15 08:30:18 +00:00
Tomasz Zawadzki
c5c7de44f3 scripts/rpc: allow methods without params in load_config/load_subsystem_config RPC
JSON-RPC allows for methods that do not contain any params.
Turns out that so far this scenario has not occured for load_config or load_sybsystem_config
RPC, which processes JSON config file saved from previous app run.

Next patch writes out bdev_wait_for_examine to bdev subsystem
configuration. As that methods does not contain any params following
error was seen:
# /home/vagrant/spdk_repo/spdk/scripts/rpc.py load_config
Traceback (most recent call last):
  File "/home/vagrant/spdk_repo/spdk/scripts/rpc.py", line 2671, in <module>
    call_rpc_func(args)
  File "/home/vagrant/spdk_repo/spdk/scripts/rpc.py", line 2601, in call_rpc_func
    args.func(args)
  File "/home/vagrant/spdk_repo/spdk/scripts/rpc.py", line 100, in load_config
    include_aliases=args.include_aliases)
  File "/home/vagrant/spdk_repo/spdk/scripts/rpc/__init__.py", line 143, in load_config
    client.call(elem['method'], elem['params'])
KeyError: 'params'

Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Change-Id: I4a56a9d0caa4b752fb9c1fad4ae581aad8a4c2c1
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5860
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: <dongx.yi@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-01-15 08:28:57 +00:00
Tomasz Zawadzki
77b6f4bc3e lib/bdev: add spdk_bdev_wait_for_examine()
Add spdk_bdev_wait_for_examine() API to be called
in order to report when examine on all registered bdevs finished.
It will be built in to most bdev modules RPC.

New RPC added to allow
- building it into bdev submodule
- user/orchestration to verify examination status manually

Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Change-Id: I27db3ae42eea3e692faeea4c2a01d04586bff438
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5480
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: <dongx.yi@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-01-15 08:28:57 +00:00
Maciej Szwed
6e3346df5b scheduler: Add option to provide scheduler period in framework_set_scheduler RPC
Signed-off-by: Maciej Szwed <maciej.szwed@intel.com>
Change-Id: I96a8937ffe8751f093227589b076a5ae77fa5f16
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5295
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-01-15 08:28:30 +00:00
Ziye Yang
f420b9ef0a bdev: Make the small and large buffer pool configurable.
This patch includes the following work:

1 Add two fields in spdk_bdev_opts structure and make the
two fields configurable.
2 Update the unit test in bdev_ut.c
3 Revise the set_bdev_options rpc call and add the support
to use the two new fields.

Change-Id: Idd6073b3a3ffaba8161e3ffa9444a9e533e67f6d
Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5664
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-12-28 14:05:34 +00:00
Jacek Kalwas
9a1cf1c594 nvmf: make transport service id optional
There are transport types like vfio-user or fc for which this field is
optional so there is no need to explicitly specify it for the add
listener rpc. Still validation of this filed is preserved for rdma and
tcp transport.

Signed-off-by: Jacek Kalwas <jacek.kalwas@intel.com>
Change-Id: I6aef55bed45b3653472fd356e5a7cfead22c6f2b
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5605
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2020-12-28 14:04:39 +00:00
Jacek Kalwas
18274baf87 Revert "nvmf: allow transport specific options within subsystem"
This reverts commit 6d87bc7a8a.

There is an issue with the desing here i.e. lifetime of the subsystem
opts shall be associated with the subsystem but the transport specific
layer is not having any notification about that. As an alternative to
the transport specific subsystem opts listener interface was extended
in a previous commit.

Change-Id: I75c4e329e411a91694959db18ff1955774f0993e
Signed-off-by: Jacek Kalwas <jacek.kalwas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5571
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-12-28 13:37:07 +00:00
Jin Yu
46a3485971 rpc: add keep alive parameter in bdev nvme
Add keep alive timetout parameter in bdev_nvme_set_options.
NVMe bdev can set this value especially when we test with
bdevperf.

Fix github issue: #1690

Change-Id: I255c935671b74cdb615a8d393e7d7e84524f3c23
Signed-off-by: Jin Yu <jin.yu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5306
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: <dongx.yi@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-12-07 14:57:03 +00:00
Jim Harris
131e617191 nvmf: remove usage of "whitelist"
NVMf subsystems can have certain hosts that are allowed.
We were previously using the term "whitelist" to refer
to those hosts.  Replace that usage as part of removing
this term from the rest of SPDK.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I2878352d83f3911aa8b59629061b818c7f1e5c96
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5282
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-12-03 09:41:07 +00:00
Jim Harris
895ad89214 ioat: remove whitelist/blacklist functionality
This can be done via explicit options on the
application command line instead.

This has the added benefit of removing a usage of
whitelist/blacklist which we are working to
remove from the SPDK repository.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I5739e281f1c29fc8a5d175f5bbc916cd7d926fe4
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5274
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-12-03 09:41:07 +00:00
Shuhei Matsumoto
d4ad1f9cc1 lib/iscsi: Add wait parameter to iscsi_create_portal_group RPC
Add an new optional parameter wait to the RPC, iscsi_create_portal_group
not to listen on portals until it is started explicitly.

Fixes the issue #1676.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ic217f1ccceb618e70fdb2aff3f710d262a8a9bdb
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5091
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-11-24 08:20:37 +00:00
Shuhei Matsumoto
024d286527 lib/iscsi: Add iscsi_start_portal_group RPC to start listening if not yet
Add an new RPC, iscsi_start_portal_group, to start listening on
portals if the specified portal group is not started yet.
The next patch will add an new parameter wait to the existing RPC,
iscsi_create_portal_group.

The RPC allows the specified portal group to be already started,
and returns a success response in this case.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I631d6bccffb38092c95694f922f10648e24d6ff7
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5090
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-11-24 08:20:37 +00:00
Allen Zhu
3e2c9092d4 rpc/bdev.py: pass zero values to SPDK when allowed
In bdev_nvme_set_options command, timeout_us/retry_count/arbitration_burst/low_priority_weight/
medium_prioity_weight/high_prioity_weight/nvme_ioq_poll_period_us/io_queue_requests can be 0,
which should be passed in the rpc command.

Signed-off-by: Allen Zhu <allenz@mellanox.com>
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Change-Id: I2ebff51b7b7de418c5ac8fbd0265444fd27e1e10
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3816
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
2020-10-27 08:40:12 +00:00
Allen Zhu
96ab62802c rpc/nvmf.py: pass zero values to SPDK when allowed
in_capsule_data_size/buf_cache_size/sock_priority/max_namespaces can be 0,
which should be passed in nvmf_create_transport/nvmf_create_subsystem commands.

Signed-off-by: Allen Zhu <allenz@mellanox.com>
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Change-Id: Ib557cf9f20f7ec2c0b3c31156cd79dbd670ce7e7
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3815
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-10-27 08:40:12 +00:00
Alexey Marchuk
4fe47d6ff4 rpc: Add new parameter 'control_msg_num' to 'nvmf_create_transport'
This parameter represents the number of control messages to be
allocated per poll group, specific for TCP transport.
The new parameter can't be zero.

Change-Id: I8ae198c0b46e9a5850a80492aa6260f0c6ef885e
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4829
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-10-27 08:40:12 +00:00
Vitaliy Mysak
a2596f4dc2 event: add scheduler_set RPC
Add RPC that allows to change scheduler at runtime.

Change-Id: I008670f5e936bc25a0fbc923b826277d15343273
Signed-off-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3958
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-10-23 22:35:53 +00:00
Ivan Betsis
bd3840a729 nvmf/rdma: Add RPC to set new RDMA batching option
Add option to enable/disable work requests batching (RDMA only).

Signed-off-by: Ivan Betsis <c_ivanb@mellanox.com>
Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Signed-off-by: Sasha Kotchubievsky <sashakot@mellanox.com>
Change-Id: I84ca599711cdc2713606444e7ec501c36671e796
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/925
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI
2020-10-21 02:25:32 +00:00
Changpeng Liu
6bd7bd0da2 vhost: deprecate internal vhost library support
The internal vhost library is used when DPDK's version
is older than 19.05 and the experiemntal vhost nvme
target.

For the CONFIG_INTERNAL_VHOST_LIB option, SPDK doesn't
enable this option by default over one year and CI
doesn't cover it either, so we may remove it with
this release.

As for the vhost-nvme target, since we are developing
a new vfio-user target solution, it's OK for us to remove
it now.

Change-Id: Ib2cce1db99cd09754307c2828b3187f2d4550304
Signed-off-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4562
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-10-20 02:42:16 +00:00
Jacek Kalwas
6d87bc7a8a nvmf: allow transport specific options within subsystem
Change-Id: Id7b7d5205b468237df4c98715ce8d7bc26145f63
Signed-off-by: Jacek Kalwas <jacek.kalwas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4246
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2020-10-05 08:23:58 +00:00
Alexey Marchuk
89d9fe558a sock/rpc: Add sock_set_default_impl RPC call
Change-Id: I11160b6e8e2a1500c80a2512a1344094b2813aa9
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4328
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-10-05 08:22:53 +00:00
Shuhei Matsumoto
c8cb51d4bc lib/nvmf: Add nvmf_subsystem_listener_set_ana_state RPC
Add an new RPC, nvmf_subsystem_listener_set_ana_state.

Find the specified subsystem listener, and then set the ANA state
of the listener by calling nvmf_subsystem_listener_set_ana_state().

By adding a string and an enum to the existing context structure,
nvmf_rpc_listener_ctx, and adding an operation type to the existng
enum, nvmf_rpc_listen_op, reuse the existing code and data as much
as possible.

Besides, insert line break into a few long lines and fix wrong
error log.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I6fb2dfbb1f9c5f56848eba21d2a733fbed802614
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4080
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-09-16 07:55:28 +00:00
paul luse
2b29a2b16c bdev/compress: rename RPC to match standard naming
Not sure how this one was missed back during the big rename party.

Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: Ia00819a2c2e8c81ad0499f4081667dde04fa726e
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4140
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: John Kariuki <John.K.Kariuki@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
2020-09-14 09:19:19 +00:00
Ziye Yang
a6db2f3590 sock: enable placement_id configuration in sock layer
This patch is used to enable placement_id getting
in sock layer and also add the rpc support.

Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Change-Id: I70de57b0ed392a0aefce9d3ff1f61ef924015a87
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4146
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-09-11 10:04:22 +00:00
Shuhei Matsumoto
9c1d648315 lib/nvmf: Add nvmf_subsystem_get_listeners RPC
Add an new RPC, nvmf_subsystem_get_listeners.

ANA state is per listener and per subsystem, and is stored in
subsystem listener. We can return ANA state by the existing
nvmf_get_subsystems RPC but it's confusing that listen addresses
have ANA states.

To change ANA state, we will provide a RPC to change ANA state of
only one selected subsystem listener.

To query ANA state, it will be convenient to get ANA states of all
listeners of one selected subsystem.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ic3baad6eac65d7af6e0cab2c4059e1458d41e6e2
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4059
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-09-09 07:20:16 +00:00
Shuhei Matsumoto
83eb352b3c lib/nvmf: Add nvmf_subsystem_get_qpairs RPC
Add an new RPC, nvmf_subsystem_get_qpairs to retrieve the list of
qpairs of an NVMe-oF subsystem.

This RPC will be usable to verify if NVMe ANA works.

Pause and resume the subsystem to access the qpairs safely.

One subtle issue remains. The JSON RPC returns success even if
resuming the subsystem fails. Write FIXME to address this.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I9d90a01b1117dee00d85b2e21b4f4d02d80db531
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4050
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-09-09 07:20:16 +00:00
JimboLuCN
dd3d5800b0 script/rpc: fix bdev_set_qos_limit's usage error
Signed-off-by: JimboLuCN <jimbolucn@gmail.com>
Change-Id: I67db5c7ef81ae77edefcc5ecf058826d3be8d2e8
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3981
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-09-01 07:51:38 +00:00
Vitaliy Mysak
d267d0e874 lib/log: add RPC to toggle timestamps
Allow toggling log timestamps on and off by adding new RPC call.

Change-Id: I34c84bf89fae352ade266fbf7fd20594ff67bced
Signed-off-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/2024
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-08-31 07:46:36 +00:00
Shuhei Matsumoto
1da94ed7b8 rpc/nvmf: Add ana_reporting parameter to nvmf_create_subsystem RPC
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I9adc8373050e68872a4d9e89518c137e61005254
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3852
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-08-21 08:22:40 +00:00
Shuhei Matsumoto
4cc04a1251 lib/nvmf: Add nvmf_subsystem_get_controllers RPC
Add an new RPC, nvmf_subsystem_get_controllers to retrieve the list
of NVMe-oF controllers of an NVMe-oF subsystem.

One of the main use cases will be to get identification information
of NVMe-oF controllers to configure their ANA states dynamically.

Pause and resume the subsystem to access the controllers safely.

One subtle issue remains. The JSON RPC returns success even if
resuming the subsystem fails. Write FIXME explicitly to address this.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ibf8d1cf56850a705e343b86022d101b4c7204199
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3848
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-08-21 08:22:40 +00:00
yupeng
2d30df9b0b bdev: add bdev_examine_bdev API
The bdev_examine_bdev api will examine a bdev explicitly. After
disabling the auto_examine feature, a user could call
bdev_examine_bdev to examine a specific bdev he/she wants.

Signed-off-by: Peng Yu <yupeng0921@gmail.com>
Change-Id: Ifbbfb6f667287669ddf6175b8208efee39762933
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3219
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Michael Haeuptle <michaelhaeuptle@gmail.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-08-20 08:56:53 +00:00
Shuhei Matsumoto
05cd697757 lib/iscsi: Add MaxR2TPerConnection to iSCSI options
Add MaxR2TPerConnection to iSCSI global options and make it configurable
by JSON RPC.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ida95e5c7dac301a22520656709e1aa4d611f31ef
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3777
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-08-18 07:27:45 +00:00
Shuhei Matsumoto
5aaf754f81 lib/iscsi: Add MaxLargeDataInPerConnection to iSCSI options
Add MaxLargeDataInPerConnection to iSCSI global options and make
it configurable by JSON RPC.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ibcd16da2eac64241217bedeb89a7929bbdc67871
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3756
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-08-18 07:27:45 +00:00
Shuhei Matsumoto
e97fd6c936 lib/iscsi: Add iscsi_target_node_request_logout RPC
For the login redirection feature, the current implementation works
only if a portal is redirected from an initial portal to a redirect
portal. However, the login redirection feature should work even if a
portal is redirected from one redirect portal to another redirect
portal.

A public portal group knows only a redirect portal and does not know
the portal group of the redirect portal.

Moreover, it is very likely that an initial portal and a redirect portal
exist in different SPDK iSCSI target applications.

To cover all these concerns, add an new iscsi_target_node_request_logout
RPC to request connections whose portal group tag match for the target
node.

To cover potential use cases, make the second parameter portal group
tag optional.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I612672490722fb22fd4eba055998b7408ab84ca5
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3780
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-08-17 08:26:59 +00:00
Shuhei Matsumoto
8cf5581fa9 lib/iscsi: Remove async logout request from iscsi_target_node_redirect()
As written in doc/iscsi.md, typically the login redirection feature
will be used in scale out iSCSI target system, which runs multiple
SPDK iSCSI target applications.

In scale out iSCSI target system, the initial portal, the current
redirect portal, and the next redirect portal are likely to be in
different SPDK iSCSI target applications.

In this case, asynchronous logout request should be sent independently
from the iSCSI target application which has the current redirect portal.

However, we had added asynchronous logout request into the iSCSI target
application which has the next redirect portal. This idea works only
for the case that login is redirected from the initial portal to a
redirect portal.

We remove asynchronous logout request from iscsi_target_node_redirect()
in this patch, and update the corresponding help documents.

The next patch will add an new RPC to send asynchronous logout
request to all connections to the specified portal group and the
specified target.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ib0ac72e8cdad7e8c64e446b7495e572fac4b5bae
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3779
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-08-17 08:26:59 +00:00
rafalste
4d91b4ef01 bdev/ocf: add cache line size
Define cache line size when creating cache device.

Signed-off-by: rafalste <rafal.stefanowski@intel.com>
Change-Id: Ica536a9bda35c355b4dd4e406a241defc1453f53
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3449
Community-CI: Mellanox Build Bot
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-08-12 10:39:56 +00:00
Seth Howell
8bff48f63c module/bdev_rpc: modify detach_ctrlr rpc to accept trid.
This will allow us to use this RPC to detach only specific
paths from controllers.

Signed-off-by: Seth Howell <seth.howell@intel.com>
Change-Id: Ib52e38aa7d4ea096418a6dc0328481c2e8db6c54
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3070
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-08-11 08:29:14 +00:00
Seth Howell
ca8c9be341 lib/bdev: fix python docs for attach_controller RPC.
Signed-off-by: Seth Howell <seth.howell@intel.com>
Change-Id: Ie4e722bd289e29691cad34418d42088c73ac002a
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3614
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
2020-08-11 08:29:14 +00:00
Shuhei Matsumoto
4ea197883c lib/iscsi: Add iscsi_target_node_set_redirect RPC
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I090f55debe4ecdc47459bcfe0571a937f064313b
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3439
Community-CI: Mellanox Build Bot
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-08-11 08:27:43 +00:00
Shuhei Matsumoto
10d6218444 lib/iscsi: Create portal group as public or private portal group
In SPDK iSCSI target, portal group works almost as identifier of
portal.

To support iSCSI login redirection, we need to have two types of
portal groups, public and private portal groups.

We need portals of public portal groups to redirect to a portal in
a private portal groups at login via temporary login redirection
funciton, and we need to make SendTargets return only portals in
public portal groups.

To do these simply, we mark primary or secondary portal group expicitly
at its creation by this patch.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Iccf87a4b9dd1f4a8fbb857a399b8f2dbc7c0b3ab
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3491
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-08-11 08:27:43 +00:00
Shuhei Matsumoto
61cd9d308e lib/sock: Add option to enable or disable quick ACK
TCP delayed ACK can be disabled or enabled by enabling or disabling
quick ACK, respectively.

The recently added spdk_sock_impl_opts is helpful for sock library
to control quick ACK.

Hence this patch adds and uses an option enable_quickack. The option
is effective only for the POSIX sock module.

We have spdk_sock_opts now too but spdk_sock_impl_opts will be better
for this case.

This option is not supported on FreeBSD. FreeBSD users can set the
option globally via sysctl if desired.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ic89620267acce5872dc8ecaf7a99bb70ae97e993
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3603
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-08-10 11:29:20 +00:00
paul luse
62b3b171cb module/compress: add new parm to RPC for create compress vol
To specify the desired logical block size. Must be 4K or 512.
If no block size is provided a default of 0 means to use the
underlying bdev block size. For cases where something other
than 4K or 512 is desired, format the underlying device
accordingly and don't specify a logical block size on creation
of the compress vol.

Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: I58b71e210cfa77b3237c0c454585c734e2e22aea
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3177
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-07-27 22:39:29 +00:00
Evgeniy Kochetov
29f31a90e1 sock: Add sock_impl option to disable zero copy on send
Zero copy send can cause performance degradation with small
payloads. This patch adds an option to disable it if required. By
default zero copy is enabled.

Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Change-Id: I14f2b21ad375e770cb08f850360898bac675b351
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3344
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-07-24 00:30:45 +00:00
Evgeniy Kochetov
63c5e51ebc sock: Add sock_impl option to disable receive pipe
Receive pipe reduces number of system calls and gives significant
performance improvement with kernel TCP stack and relatively small IO
sizes. With user space TCP/IP implementations there are no system
calls and double buffering introduced by pipe has negative impact on
performance. Receive pipe remains enabled by default.

Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Change-Id: Ic5ddee42293df2c233ba7ffbe6662de7917ac586
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3343
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-07-24 00:30:45 +00:00
Shuhei Matsumoto
26e0ef9a36 lib/nvmf: Make abort execution timeout value optional
Make the abort execution timeout value as optional.

Zero is acceptable and means immediate timeout.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ia4b03c65b8bd15899f48be9476ee657446147581
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3104
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Michael Haeuptle <michaelhaeuptle@gmail.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-07-16 07:29:46 +00:00
Seth Howell
3b830202ca lib/nvmf: add an acceptor_backlog transport opt.
This allows users to configure the number of
connection requests outstanding to an rdma port
at once.

RPC included.

Signed-off-by: Seth Howell <seth.howell@intel.com>
Change-Id: I8a2bb86b2fb7565cb10288088d39af763b778703
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3097
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2020-07-08 07:57:04 +00:00
Evgeniy Kochetov
b1074c4905 sock/rpc: Add sock_impl_get/set_options RPC methods
Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Change-Id: If1193ef647c85b045d7f14a03a9942783583f553
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/612
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-07-07 07:32:32 +00:00
Ben Walker
c37cf9fbd8 nvmf: Make transport-chosen the only valid qpair scheduler
The transport always knows best.

Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Change-Id: If66f539033fe11c50dc42e12ec990468588d5739
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/2812
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2020-06-16 07:44:49 +00:00
Darek Stojaczyk
00b52bf5dd scripts/rpc.py: add new parameter to retry connecting
This can potentially replace waitforlisten() in our test scripts.

$ ./scripts/rpc.py -h
  -r CONN_RETRIES       Retry connecting to the RPC server N times with
                        0.2s interval. Default: 0
[...]

$ ./scripts/rpc.py -r 10 spdk_get_version
<SNIP the usual python exception>
rpc.client.JSONRPCException: Error while connecting to
/var/tmp/spdk.sock
Error details: [Errno -2] Name or service not known

real    0m2.452s
user    0m0.242s
sys     0m0.020s

Change-Id: I204da366360647fcce8f8de0eb25b0f576aabc5b
Signed-off-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/2751
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2020-06-08 09:35:16 +00:00
Alexey Marchuk
1551197db5 rpc: Deprecate max_qpairs_per_ctrlr parameter
This parameter describes the number of admin and IO
qpairs while admin qpair always exists and should not
be configured explicitly.
Introduce a new parameter `max_io_qpairs_per_ctrlr`
which configures the number of IO qpairs.
Internal structure of NVMF transport is not changed,
both RPC parameters configure the same nvmf transport parameter.

Deprecate max_qpairs_per_ctrlr in spdkcli as well

Side change: update dif_insert_or_strip description -
it can be used by TCP and RDMA transports

Config files parsing is not changed since it is deprecated

Fixes #1378

Change-Id: I8403ee6fcf090bb5e86a32e4868fea5924daed23
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/2279
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Anil Veerabhadrappa <anil.veerabhadrappa@broadcom.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Community-CI: Broadcom CI
2020-06-04 07:20:45 +00:00
yupeng
240b243af5 bdev: add doc for bdev_auto_examine
Explain the bdev_auto_examine parameter of the bdev_set_options rpc.
Add bdev_auto_examine parameter for the bdev_set_options
in the python rpc client.

Signed-off-by: Peng Yu <yupeng0921@gmail.com>
Change-Id: I268cd5c01129180467967c2ebfffa7c3ba7e5b1a
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/2580
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-05-29 14:58:16 +00:00
Michal Berger
871214e2c1 rpc.py: Allow loading json config from different sources
This is relevant in context of rpc_cmd() which was introduced with the
following commit:

     "scripts/rpc.py: add daemon mode" 8b98cdb64a

When rpc.py runs in a server mode, its stdin is already attached to a
pipe connected to its parent Bash process. In such a setup, it's not
possible to use some of the rpc methods, e.g. load_config().

To make use of said methods possible, allow them to load the config
from different sources - a regular file or a string.

Change-Id: I6fa7d13fa1957b6449ce5d5c5a810bd58d0a5703
Signed-off-by: Michal Berger <michalx.berger@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/2106
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
2020-05-13 07:46:04 +00:00
paul luse
3044bd27d0 lib/accel: remove RPC for setting the module
This was added before the usage of having a SW engine and 2 HW
engines was fully thought out. The current rules are:

* if no HW engine specific enable RPC is sent, use SW
* if a HW engine specific enable RPC is sent, use it
* If a 2nd HW engine specific enable RPC is sent, ignore

In this scheme there's no need for an RPC that lets the user
choose which engine to use because they already do so when
they enable an engine.

Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: I006ffb3b417f1e93bb061b29535d157ba66f03b4
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/2033
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
2020-05-07 10:41:44 +00:00
Ziye Yang
94345a0a1a nvme: Add the priority field in struct spdk_nvme_transport_id
Purpose: To set the priority of the NVMe-oF connection especially
for TCP connection.

For example, the previous example can be:

trtype:TCP adrfam:IPv4 traddr:10.67.110.181 trsvcid:4420

With the change, it could be:

trtype:TCP adrfam:IPv4 traddr:10.67.110.181 trsvcid:4420 priority:2

The priority is optional. We try to change
spdk_nvme_transport_id but not in spdk_nvme_ctrlr_opts since
the opts in spdk_nvme_ctrlr_opts will reflect in every nvme ctrlr,
this is short of flexibility.

Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Signed-off-by: Sudheer Mogilappagari <sudheer.mogilappagari@intel.com>
Change-Id: I1ba364c714a95f2dbeab2b3fcc832b0222b48a15
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/1875
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-04-24 15:53:34 +00:00
paul luse
42eb233e48 scripts/rpc: addd RPC support to enable idxd
The new RPC also includes and option for which
idxd config is to be used. Config options will be
explained in detail in a later patch.

Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: I1322bab4d6ca9cc45ec3a56d7267dc7dc09dbea3
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/1726
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-04-23 15:48:32 +00:00
Liang Yan
6a29c6a906 bdev/rbd: add ceph rbd resize function.
Signed-off-by: Liang Yan <liang.z.yan@intel.com>
Change-Id: Id7f24f1f5e0789ee6d4c07ae7f59cc2d98983e98
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/1766
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-04-23 07:28:10 +00:00
Jin Yu
2eabc71518 vhost: add packed ring support
Update vhost blk contruct rpc, make it enable to
support packed ring feature.

Change-Id: Ia1f75e72e8441e8d82fad89073e4875f89e5b9cd
Signed-off-by: Jin Yu <jin.yu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/1567
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
2020-04-15 03:55:59 +00:00
Karol Latecki
051a6902d8 rpc/client.py: replace use process_time() instead of time()
time.clock() was depreceted since Python 3.3 and was finally
removed in Python 3.8.
https://docs.python.org/3.8/whatsnew/3.8.html#api-and-feature-removals

Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Change-Id: I3ffe372b61c8afc0ddbbee0064b95059fa184616
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/1369
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2020-03-23 09:37:44 +00:00
Shuhei Matsumoto
49cffc1e68 rpc: Add thread_get_io_channels RPC
Add an new JSON RPC thread_get_io_channels to retrieve IO channels
of the threads. IO channel don't have its own name and so get the
name of the corresponding IO device instead.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Id8fbb328ffba09e1eace35994cdbf36b24832b82
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/887
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
2020-03-10 09:13:02 +00:00
Shuhei Matsumoto
0b0f0c5415 rpc: Add thread_get_pollers RPC
Add an new JSON RPC thread_get_pollers to retrieve pollers of all
the threads. By adding a helper function spdk_poller_state_str(),
output poller state as string to improve readability. Most of the
code of thread_get_stats and thread_get_pollers are common and so
unify these two RPCs as possible as we can.

Sample output of thread_get_stats RPC in doc/jsonrpc.md was wrong
because thread_get_stats doesn't output ticks. Fix this together.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I003ffe569d3c0651ae65c5858eff8287f7e9031d
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/604
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2020-03-06 10:29:56 +00:00
Shuhei Matsumoto
95b35daa5f rpc: Add thread_set_cpumask RPC
Add an new JSON RPC thread_set_cpumask to control CPU affinity of
the thread dynamically from outside of SPDK application.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I6b6b794405f612200a2c3cb27dc4fc1ad2e88bec
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/501
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2020-03-04 10:03:30 +00:00
paul luse
f070b78cd1 module/crypto: add RPC and plumbing to support QAT AES_XTS cipher
Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: Iadd03f8da305e97e3f1d57ef4aeaece400e8d959
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/441
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2020-02-18 08:05:42 +00:00
paul luse
e753402aa1 lib/accel: add RPC to select which accel module should be used
Startup RPC only to avoid issues trying to switch while in use.

Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: I7f1801905de0927f3610c4065182dd8fa88cdfdd
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/660
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2020-02-18 08:05:34 +00:00
paul luse
aa7a13afc7 global: rename copy to accel
The copy engine library, modules and public APIs have been renamed.
Use of the word `copy` has been replaced with the word `accel`
short for accelerator in preparation for adding new capabilities
in the future. Additionally, APIs for what was previously called
the `memcpy` engine have been renamed to identify the engine as a
software accelerator.

Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: Ia607aa718416146fbba1e6792b8de0f66bd8a5de
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/576
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2020-02-18 08:05:34 +00:00
paul luse
e914958951 module/compress: rename set_compress_pmd RPC to match convention
set_compress_pmd -> compress_set_pmd

Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: Icb1ecc7adfe10485c44f98ab9e31eaa6857596e7
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/482597
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Community-CI: SPDK CI Jenkins <sys_sgci@intel.com>
2020-01-31 12:37:31 +00:00
Michael Haeuptle
c9874b91a7 lib/nvmf: custom admin handler config
This commit disables the custom identify handler by default.
The user has to explictly enable this handler via the set_nvmf_config
RPC or conf file.

Change-Id: I767816ba7639ebe78683993408ce6db02c7620fe
Signed-off-by: Michael Haeuptle <michael.haeuptle@hpe.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/479603
Community-CI: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-01-20 09:56:35 +00:00
Wojciech Malikowski
f2c8083ef3 lib/ftl: Functional tests
This patch adjust functional tests to
new FTL stack.

Change-Id: I0b8ff08c61793d7f1685942031aecf9cc88d1f24
Signed-off-by: Wojciech Malikowski <wojciech.malikowski@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/468738
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
2020-01-15 12:24:44 +00:00
Wojciech Malikowski
52a9661d94 bdev/ftl: Remove punit parameter from ftl bdev configuration
FTL library is consuming whole OCSSD device
so punit parameter is not needed for bdev ftl
configuration.

Change-Id: I56f62ea6d09b3157b70c02ccfffcd3cb07ba4597
Signed-off-by: Wojciech Malikowski <wojciech.malikowski@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/467950
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
2020-01-10 08:42:51 +00:00
Shuhei Matsumoto
876fdf2a59 event/rpc: Add framework_get_reactors RPC
Add an new RPC `framework_get_reactors` to retrieve list of all
reactors.  Running threads on each reactor are included
in the output.  Update jsonrpc.md and CHANGELOG accordingly.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I985d087dd41afe3033b7678af141ec8e5a2a822e
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/478027
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Alexey Marchuk <alexeymar@mellanox.com>
2020-01-03 08:33:25 +00:00
Konrad Sztyber
64fe514efa bdev/ocssd: parallel unit ranges
This patch adds the ability to create bdevs on specified parallel unit
ranges on one OCSSD controller.  It allows the user to create multiple
isolated bdevs, each operating on a separate set of parallel units.

To create a bdev on a specified range, a new parameter -r|--range was
added. For example:
 rpc.py bdev_ocssd_create -c nvme0 -b nvme0n1 -r 0-4

will create a bdev on parallel units 0 through 4 (inclusive).  If the
parameter is ommited, the bdev will span across all available units.

Change-Id: Icd94cf1e22fcc72806ef1ce1efd2d7031010009f
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/469898
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2019-12-20 10:02:15 +00:00
Seth Howell
de467ec91d env_dpdk/rpc: add rpc to get memory stats.
This will enable us to create a helper applciation to print memory
statistics for a given SPDK application.

Change-Id: I0ad5a8163166a5d67d9a5533303ec0858297ba6b
Signed-off-by: Seth Howell <seth.howell@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/477511
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
Community-CI: SPDK CI Jenkins <sys_sgci@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2019-12-13 11:05:57 +00:00
Evgeniy Kochetov
542be8790b nvme/rpc: Make 'delay_cmd_submit' configurable via RPC
Optional parameter 'delay_cmd_submit' has been added to
'bdev_nvme_set_options' RPC method.

Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Signed-off-by: Sasha Kotchubievsky <sashakot@mellanox.com>
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Change-Id: Ia09c57bbac8078ee6ab1e8f0bd279ffeb9e08cb8
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/462584
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
2019-12-10 17:32:10 +00:00
Tomasz Kulasek
b7b45bc7bc lib/nvme: remove device name parameter from nvme cuse
This patch removes posibility to set cuse device path. Instead
"/dev/spdk/nvme*" path is used.


Change-Id: I7c3087772a3661eebe03fce21356c35cc8204b49
Signed-off-by: Tomasz Kulasek <tomaszx.kulasek@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/474598
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2019-12-09 17:40:35 +00:00
Konrad Sztyber
6bda87b324 bdev/ocssd: create / delete calls
Added a way to create and delete OCSSD bdevs on top of OC NVMe
controller.  The controller can be created using the regular NVMe bdev
RPC call.  For instance, the following (assuming 0000:00:04.0 is an
OC device):

 rpc.py bdev_nvme_attach_controller -b nvme0 -a 0000:00:04.0 -t pcie
 rpc.py bdev_ocssd_create -c nvme0 -b nvme0n1

creates Open Channel controller nvme0 and OCSSD bdev nvme0n1 on top of
it.  The bdevs can be deleted either by the bdev_ocssd_delete call or by
deleting whole NVMe controller, in which case all bdevs are destroyed.

Change-Id: I9f2f02103fc5570a53bd26479c8690be206829c3
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/468984
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Wojciech Malikowski <wojciech.malikowski@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2019-12-06 14:45:05 +00:00
Jim Harris
8bc9798dc7 rpc.py: add new kv to existing params dict
When we get an error when calling an RPC, client.py
makes extensive use of the ** operator to add
the method and req_id to the params dict variable.

This doens't work with Python 2.  We don't really
support Python 2, but there are at least some folks
out there who make their own mods to get rpc.py
to work with it.  We can very easily implement this in
a way that is Python 2 friendly, so let's do that
to make it a tiny bit easier for those folks.

Incidentally, I do think the changes here also make
this part of the code a bit easier to read and
understand.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I1846c80e21032ffba67128bee946b041a61d0621

Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/476632
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2019-12-05 12:23:30 +00:00
Mateusz Kozlowski
195be29e9b bdev/zone: Rpc functions for zoned block bdev
Added rpc handling for creation and deletion of zoned block bdev

Signed-off-by: Mateusz Kozlowski <mateusz.kozlowski@intel.com>
Change-Id: Ib7b6f3928511aa840cbe098472682c951e92e5ed
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/468031
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2019-11-15 20:27:14 +00:00
Yao Liu
ec2ba7aade bdev/uring: add an argument to specify block size
The block size of non-disk files can't be automatically detected,
so add an argument to specify it.

Signed-off-by: Yao Liu <yotta.liu@ucloud.cn>
Change-Id: Ia11ab177b78c66ede4a09a997bba28827d83ec25
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/473607
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2019-11-13 15:06:30 +00:00
Pawel Kaminski
e0c4db2acb rpc: Fix - Use correct deprecated alias name for bdev_nvme_set_hotplug
Change-Id: Ia9869abc73da2d074500f449a943ddb12afc5d76
Signed-off-by: Pawel Kaminski <pawelx.kaminski@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/473587
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2019-11-08 16:02:36 +00:00
Xiaodong Liu
138e6daec3 rpc/blobfs: add cache size setting rpc
This RPC method can be used to set cache size of
blobfs, in case a smaller or larger memory scale
is requred by cache pool.

Change-Id: I8046c7caeaa15c67825f86d14ae0b79395d51daf
Signed-off-by: Xiaodong Liu <xiaodong.liu@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/471870
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2019-11-07 00:33:25 +00:00
Yao Liu
ff93f0f9d6 bdev/uring: make uring rpc interface unified with aio
Signed-off-by: Yao Liu <yotta.liu@ucloud.cn>
Change-Id: I338c63f1acf17c3b2a8612dd71952617076ec8f9
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/472676
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2019-11-06 14:43:57 +00:00
Tomasz Kulasek
74906b01b6 lib/nvme: add RPC for interacting with CUSE devices
Added RPC commands to register/unregister CUSE devices
to NVMe controllers:

 - bdev_nvme_cuse_register
 - bdev_nvme_cuse_unregister

Additionally two RPC now return CUSE device names:

 - bdev_get_bdevs for namespaces
 - bdev_nvme_get_controllers for controllers


Signed-off-by: Maciej Szwed <maciej.szwed@intel.com>
Change-Id: I69c4bf41ec8f78a7522894268a67dd733881712f
Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Signed-off-by: Tomasz Kulasek <tomaszx.kulasek@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/472211
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2019-10-24 23:43:59 +00:00
John Kariuki
c8b6a884fd bdev/uring: add rpc calls
added rpc calls for configuring uring bdevs

Signed-off-by: John Kariuki <John.K.Kariuki@intel.com>
Change-Id: I6c8273fd6e869402fcc244c9a08226d0c2db025c
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/471323
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2019-10-24 17:31:06 +00:00
Chunyang Hui
bc40f5f661 bdev/opal: Add rpc commands for multiuser
Add rpc commands bdev_opal_lock_unlock, bdev_opal_new_user.
Admin can add new user for opal bdev created and the user can
lock/unlock the bdev by himself.

Change-Id: I9a1e360399617b5a039dc5353097ab525c7eb964
Signed-off-by: Chunyang Hui <chunyang.hui@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/471475
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2019-10-24 17:09:57 +00:00
Chunyang Hui
36c9ac2dde bdev/opal: Add rpc for init, revert and get info
Add bdev_nvme_opal_init, bdev_nvme_opal_revert,
bdev_opal_get_info rpc commands.

Change-Id: Ib53492c02a1c18603834640d23f9fb2e7eb08657
Signed-off-by: Chunyang Hui <chunyang.hui@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/468917
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2019-10-24 17:09:57 +00:00
Chunyang Hui
0a18f228c3 opal: Add rpc for create and delete opal bdev
Change-Id: Ic2cbe079aa16d839b92fc4d0b3ee64c061fa2d3e
Signed-off-by: Chunyang Hui <chunyang.hui@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/468191
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: yidong0635 <dongx.yi@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2019-10-24 17:09:57 +00:00
Marcin Dziegielewski
20894340f2 lib/bdev/ocf: update of ocf library to version 19.06
This path updates ocf library to version 19.06 and also introduces
all necessary changes required to integrate ocf bdev adapter with
new version of ocf.

Summary of changes introduces with new OCF in ocf bdev:
- ocf_env.h increased limit for memory operations, changed behaviour
of strncpy to less restrictive, both changes are required to run new OCF
- ctx.c changed functions to new from new OCF
- added new cache mode "write only"
- added missed cache modes wa and wi to RPC scripts
- rewritten spdk_rpc_bdev_ocf_get_stats function to use asynhronus
ocf_mngt_cache_read_lock
- used new asynhronus ocf_mngt_cache_flush instead of waiting for request
- removed no longer valid filed - cfg->device.min_free_ram
- changed expected result in metadata_probe_cb

Signed-off-by: Marcin Dziegielewski <marcin.dziegielewski@intel.com>
Change-Id: I83e4335e16600e4d22e6bb517931102de42d39e9
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/468132
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2019-10-22 17:22:41 +00:00
Xiaodong Liu
9c6e742679 blobfs: add blobfs_mount RPC as FUSE
This RPC method will mount blobfs on bdev to one host
path through FUSE. Then on the host path, user can
directly do some file operations which will be mapped
to blobfs.

Note:
* The FUSE mount of blobfs can be umounted directly by
SHELL umount or fusermount command.

Change-Id: I7c322d978b39bbc7255fced345a749ad5bfa7077
Signed-off-by: Xiaodong Liu <xiaodong.liu@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/468777
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
2019-10-15 16:25:09 +00:00