Commit Graph

440 Commits

Author SHA1 Message Date
Michal Berger
10b7805b0f scripts/rpc: Make sure address argument is properly interpreted
In case the addr argument was not an existing unix socket file the rpc
client would consider it to be an actual ip address. As a result
connect() would be called with improper set of arguments. This could
cause the rpc.py to block for undesired amount of time until connect()
finally decided to return (seen on some fedora33 builds).

This was affecting sh wrapper functions like waitforlisten() which
use rpc.py to determine if given app is ready to be talk to blocking
execution of the tests for way too long then intendent.

To avoid such a scenario determine the format of the address and use
routines proper for given address family.

Signed-off-by: Michal Berger <michalx.berger@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7777 (master)

(cherry picked from commit 6c1a1a3dca)
Change-Id: Iaac701d72c772629fa7c6478ff4781b0c5d485d5
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/8018
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Michal Berger <michalx.berger@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2021-05-31 07:11:13 +00:00
Alexey Marchuk
e6e51ea9a2 sock: Deprecate enable_zerocopy_send in sock_impl_set_options RPC
This deprecated parameter will be removed in SPDK 21.07

Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7608 (master)

(cherry picked from commit 2fd97e28bf)
Change-Id: I2b2fbcc798bb50fa6f9dfe35045f66e41c1ceaa9
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7639
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2021-04-27 16:25:00 +00:00
Alexey Marchuk
d9efb8f004 sock: Add new params to configure zcopy for server, client sockets
When zcero copy send is enabled and used by initiator,
it could significantly increase latency in some payloads.
To enable more fine graing configuration of zero copy
send feature, add new parameters enable_zerocopy_send_server
and enable_zerocopy_send_client to spdk_sock_impl_opts to
enable/disable zcopy for specific type of sockets.
Exisiting enable_zerocopy_send parameter affects all types
of sockets.

Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7457 (master)

(cherry picked from commit 8e85b675fc)
Change-Id: I111c75608f8826980a56e210c076ab8ff16ddbdc
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7638
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2021-04-27 16:25:00 +00:00
Jin Yu
2f600ca75e virtio-blk: add hotplug rpc
Change-Id: I4ed583d91ae9e820be1ee6f4553f29d6650c4922
Signed-off-by: Jin Yu <jin.yu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5791
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2021-04-16 19:21:13 +00:00
Alexey Marchuk
5c33437b99 bdev_nvme: Add RPC to dump transport statistics
The new RPC bdev_nvme_get_transport_statistics is added.

Change-Id: Ic13d096717c041fd3e0b77eaebca6ae09239698b
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6303
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2021-04-13 21:30:52 +00:00
Rafal Stefanowski
5bdaec6322 ocf/rpc: Add bdev_ocf_set_cache_mode method
This method allows to dynamically switch cache mode on OCF bdev

Signed-off-by: Rafal Stefanowski <rafal.stefanowski@intel.com>
Change-Id: I933273e35bb9f29528657f8f6800c6b52dde32e5
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6547
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-03-18 14:39:09 +00:00
Richael Zhuang
201aa63471 sock: introduce SO_INCOMING_CPU to get placement_id
Leverage SO_INCOMING_CPU to get the CPU affinity of connections
(sockets). And allocate the connections to specific poll groups,
which aims to utilize cache locality.

From our test:
6 P4600 NVMe on target,target uses 8 cores, NIC irqs are bound to
these 8 cores, and initiator side uses 24 and 32 cores,
we can get 11%~17% randwrite performance boost for posix, and 8%~12%
for uring.

Change-Id: I011e0a21502c85adcccd4a14fbe9838b43f54976
Signed-off-by: Richael Zhuang <richael.zhuang@arm.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5748
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-03-09 08:53:52 +00:00
Jim Harris
9713bfe90d rpc.py: print better message if cannot connect
We need to catch the JSONRPCException when we cannot
connect, so that the error message can be printed
more cleanly. Also suggest to the user that maybe
they don't have an SPDK application running when
it cannot connect.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I497bed86573d5bf07a2b48b3d6682a2427aa4987
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6754
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Monica Kenguva <monica.kenguva@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2021-03-09 08:53:36 +00:00
Monica Kenguva
97ef870100 nvmf/rdma: add RPC parameter to specify CQ size with RDMA transport
nvmf_create_transport rpc parameter to configure the CQ size helps
if the user is aware of CQ size needed as iWARP doesn't support CQ resize.

Fixes issue #1747

Signed-off-by: Monica Kenguva <monica.kenguva@intel.com>
Change-Id: Ia9ba2b5f612993be27ebfa3455fb4fefd80ae738
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6495
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2021-03-04 08:14:57 +00:00
Shuhei Matsumoto
20f1cf632b bdev/ocssd: Remove range parameter from bdev_ocssd_create RPC
It has been confirmed that there is no affected use case in
the SPDK community when we remove the range parameter from
the bdev_ocssd_create RPC.

Hence, remove the range parameter from the bdev_ocssd_create RPC,
remove range parameter from bdev_ocssd_create_bdev(), remove range
info from ocssd_bdev_config_json(), and then update unit tests
accordingly.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I1b0a541b61bf26732fd028dc43becb7ca2384f8e
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6220
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2021-02-19 11:28:53 +00:00
Alexey Marchuk
05aeb9db27 bdev/nvme/rpc: Add params to enable TCP hdgst and ddgst
Function bdev_nvme_create accpets new parameter - ctrlr
opts which is passed and filled by RPC handler. That
will allow us to add config parameters for other ctrlr
options with minimal changes.

Change-Id: I96ac1b21e7a3816c652765cddade75423eb843ca
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6023
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: <dongx.yi@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2021-02-09 11:26:51 +00:00
Krzysztof Karas
abf52d7d7f spdk_top: add rpc for scheduler and governor
Added rpc to get name and period of currently set spdk scheduler
and name of currently set spdk governor.

Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Change-Id: I5562a81a7f9e4879bd48a765c9467f70b43f73ab
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5917
Community-CI: Broadcom CI
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Maciej Szwed <maciej.szwed@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2021-01-22 18:33:13 +00:00
Jin Yu
d0657f3230 bdev_null: add null bdev resize rpc
Usually null bdev is used in testing.
The resize function provides flexibility

Change-Id: I603db0b85ff13a86d38ccc8dd6f260807393df93
Signed-off-by: Jin Yu <jin.yu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5797
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-01-18 13:03:02 +00:00
Karol Latecki
df2c932e09 scripts/rpc: fix framework_set_schedule period parameter
Period parameter is marked as optional in rpc.py. This works
as long the rpc call is issued with rpc.py, as argparse
sets period to "None" by default. This patch makes it
an optional argument as well directly in app.py.

Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Change-Id: I2e3cae6df7edd7fc6e1120ee3d4a2655dc60813a
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5942
Reviewed-by: Michal Berger <michalx.berger@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
2021-01-18 08:17:28 +00:00
Jin Yu
2969c5ab30 vhost-blk: recover ring base when reconnect
This patch is for packed ring and recover the ring
base when vhost target reconnect to QEMU.

Change-Id: I73f791b4a55adf9834112afd7dd7bb26c75a135d
Signed-off-by: Jin Yu <jin.yu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4128
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2021-01-15 08:30:18 +00:00
Tomasz Zawadzki
c5c7de44f3 scripts/rpc: allow methods without params in load_config/load_subsystem_config RPC
JSON-RPC allows for methods that do not contain any params.
Turns out that so far this scenario has not occured for load_config or load_sybsystem_config
RPC, which processes JSON config file saved from previous app run.

Next patch writes out bdev_wait_for_examine to bdev subsystem
configuration. As that methods does not contain any params following
error was seen:
# /home/vagrant/spdk_repo/spdk/scripts/rpc.py load_config
Traceback (most recent call last):
  File "/home/vagrant/spdk_repo/spdk/scripts/rpc.py", line 2671, in <module>
    call_rpc_func(args)
  File "/home/vagrant/spdk_repo/spdk/scripts/rpc.py", line 2601, in call_rpc_func
    args.func(args)
  File "/home/vagrant/spdk_repo/spdk/scripts/rpc.py", line 100, in load_config
    include_aliases=args.include_aliases)
  File "/home/vagrant/spdk_repo/spdk/scripts/rpc/__init__.py", line 143, in load_config
    client.call(elem['method'], elem['params'])
KeyError: 'params'

Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Change-Id: I4a56a9d0caa4b752fb9c1fad4ae581aad8a4c2c1
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5860
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: <dongx.yi@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-01-15 08:28:57 +00:00
Tomasz Zawadzki
77b6f4bc3e lib/bdev: add spdk_bdev_wait_for_examine()
Add spdk_bdev_wait_for_examine() API to be called
in order to report when examine on all registered bdevs finished.
It will be built in to most bdev modules RPC.

New RPC added to allow
- building it into bdev submodule
- user/orchestration to verify examination status manually

Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Change-Id: I27db3ae42eea3e692faeea4c2a01d04586bff438
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5480
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: <dongx.yi@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-01-15 08:28:57 +00:00
Maciej Szwed
6e3346df5b scheduler: Add option to provide scheduler period in framework_set_scheduler RPC
Signed-off-by: Maciej Szwed <maciej.szwed@intel.com>
Change-Id: I96a8937ffe8751f093227589b076a5ae77fa5f16
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5295
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-01-15 08:28:30 +00:00
Ziye Yang
f420b9ef0a bdev: Make the small and large buffer pool configurable.
This patch includes the following work:

1 Add two fields in spdk_bdev_opts structure and make the
two fields configurable.
2 Update the unit test in bdev_ut.c
3 Revise the set_bdev_options rpc call and add the support
to use the two new fields.

Change-Id: Idd6073b3a3ffaba8161e3ffa9444a9e533e67f6d
Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5664
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-12-28 14:05:34 +00:00
Jacek Kalwas
9a1cf1c594 nvmf: make transport service id optional
There are transport types like vfio-user or fc for which this field is
optional so there is no need to explicitly specify it for the add
listener rpc. Still validation of this filed is preserved for rdma and
tcp transport.

Signed-off-by: Jacek Kalwas <jacek.kalwas@intel.com>
Change-Id: I6aef55bed45b3653472fd356e5a7cfead22c6f2b
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5605
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2020-12-28 14:04:39 +00:00
Jacek Kalwas
18274baf87 Revert "nvmf: allow transport specific options within subsystem"
This reverts commit 6d87bc7a8a.

There is an issue with the desing here i.e. lifetime of the subsystem
opts shall be associated with the subsystem but the transport specific
layer is not having any notification about that. As an alternative to
the transport specific subsystem opts listener interface was extended
in a previous commit.

Change-Id: I75c4e329e411a91694959db18ff1955774f0993e
Signed-off-by: Jacek Kalwas <jacek.kalwas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5571
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-12-28 13:37:07 +00:00
Jin Yu
46a3485971 rpc: add keep alive parameter in bdev nvme
Add keep alive timetout parameter in bdev_nvme_set_options.
NVMe bdev can set this value especially when we test with
bdevperf.

Fix github issue: #1690

Change-Id: I255c935671b74cdb615a8d393e7d7e84524f3c23
Signed-off-by: Jin Yu <jin.yu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5306
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: <dongx.yi@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-12-07 14:57:03 +00:00
Jim Harris
131e617191 nvmf: remove usage of "whitelist"
NVMf subsystems can have certain hosts that are allowed.
We were previously using the term "whitelist" to refer
to those hosts.  Replace that usage as part of removing
this term from the rest of SPDK.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I2878352d83f3911aa8b59629061b818c7f1e5c96
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5282
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-12-03 09:41:07 +00:00
Jim Harris
895ad89214 ioat: remove whitelist/blacklist functionality
This can be done via explicit options on the
application command line instead.

This has the added benefit of removing a usage of
whitelist/blacklist which we are working to
remove from the SPDK repository.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I5739e281f1c29fc8a5d175f5bbc916cd7d926fe4
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5274
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-12-03 09:41:07 +00:00
Shuhei Matsumoto
d4ad1f9cc1 lib/iscsi: Add wait parameter to iscsi_create_portal_group RPC
Add an new optional parameter wait to the RPC, iscsi_create_portal_group
not to listen on portals until it is started explicitly.

Fixes the issue #1676.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ic217f1ccceb618e70fdb2aff3f710d262a8a9bdb
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5091
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-11-24 08:20:37 +00:00
Shuhei Matsumoto
024d286527 lib/iscsi: Add iscsi_start_portal_group RPC to start listening if not yet
Add an new RPC, iscsi_start_portal_group, to start listening on
portals if the specified portal group is not started yet.
The next patch will add an new parameter wait to the existing RPC,
iscsi_create_portal_group.

The RPC allows the specified portal group to be already started,
and returns a success response in this case.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I631d6bccffb38092c95694f922f10648e24d6ff7
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5090
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-11-24 08:20:37 +00:00
Allen Zhu
3e2c9092d4 rpc/bdev.py: pass zero values to SPDK when allowed
In bdev_nvme_set_options command, timeout_us/retry_count/arbitration_burst/low_priority_weight/
medium_prioity_weight/high_prioity_weight/nvme_ioq_poll_period_us/io_queue_requests can be 0,
which should be passed in the rpc command.

Signed-off-by: Allen Zhu <allenz@mellanox.com>
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Change-Id: I2ebff51b7b7de418c5ac8fbd0265444fd27e1e10
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3816
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
2020-10-27 08:40:12 +00:00
Allen Zhu
96ab62802c rpc/nvmf.py: pass zero values to SPDK when allowed
in_capsule_data_size/buf_cache_size/sock_priority/max_namespaces can be 0,
which should be passed in nvmf_create_transport/nvmf_create_subsystem commands.

Signed-off-by: Allen Zhu <allenz@mellanox.com>
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Change-Id: Ib557cf9f20f7ec2c0b3c31156cd79dbd670ce7e7
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3815
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-10-27 08:40:12 +00:00
Alexey Marchuk
4fe47d6ff4 rpc: Add new parameter 'control_msg_num' to 'nvmf_create_transport'
This parameter represents the number of control messages to be
allocated per poll group, specific for TCP transport.
The new parameter can't be zero.

Change-Id: I8ae198c0b46e9a5850a80492aa6260f0c6ef885e
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4829
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-10-27 08:40:12 +00:00
Vitaliy Mysak
a2596f4dc2 event: add scheduler_set RPC
Add RPC that allows to change scheduler at runtime.

Change-Id: I008670f5e936bc25a0fbc923b826277d15343273
Signed-off-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3958
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-10-23 22:35:53 +00:00
Ivan Betsis
bd3840a729 nvmf/rdma: Add RPC to set new RDMA batching option
Add option to enable/disable work requests batching (RDMA only).

Signed-off-by: Ivan Betsis <c_ivanb@mellanox.com>
Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Signed-off-by: Sasha Kotchubievsky <sashakot@mellanox.com>
Change-Id: I84ca599711cdc2713606444e7ec501c36671e796
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/925
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI
2020-10-21 02:25:32 +00:00
Changpeng Liu
6bd7bd0da2 vhost: deprecate internal vhost library support
The internal vhost library is used when DPDK's version
is older than 19.05 and the experiemntal vhost nvme
target.

For the CONFIG_INTERNAL_VHOST_LIB option, SPDK doesn't
enable this option by default over one year and CI
doesn't cover it either, so we may remove it with
this release.

As for the vhost-nvme target, since we are developing
a new vfio-user target solution, it's OK for us to remove
it now.

Change-Id: Ib2cce1db99cd09754307c2828b3187f2d4550304
Signed-off-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4562
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-10-20 02:42:16 +00:00
Jacek Kalwas
6d87bc7a8a nvmf: allow transport specific options within subsystem
Change-Id: Id7b7d5205b468237df4c98715ce8d7bc26145f63
Signed-off-by: Jacek Kalwas <jacek.kalwas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4246
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2020-10-05 08:23:58 +00:00
Alexey Marchuk
89d9fe558a sock/rpc: Add sock_set_default_impl RPC call
Change-Id: I11160b6e8e2a1500c80a2512a1344094b2813aa9
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4328
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-10-05 08:22:53 +00:00
Shuhei Matsumoto
c8cb51d4bc lib/nvmf: Add nvmf_subsystem_listener_set_ana_state RPC
Add an new RPC, nvmf_subsystem_listener_set_ana_state.

Find the specified subsystem listener, and then set the ANA state
of the listener by calling nvmf_subsystem_listener_set_ana_state().

By adding a string and an enum to the existing context structure,
nvmf_rpc_listener_ctx, and adding an operation type to the existng
enum, nvmf_rpc_listen_op, reuse the existing code and data as much
as possible.

Besides, insert line break into a few long lines and fix wrong
error log.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I6fb2dfbb1f9c5f56848eba21d2a733fbed802614
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4080
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-09-16 07:55:28 +00:00
paul luse
2b29a2b16c bdev/compress: rename RPC to match standard naming
Not sure how this one was missed back during the big rename party.

Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: Ia00819a2c2e8c81ad0499f4081667dde04fa726e
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4140
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: John Kariuki <John.K.Kariuki@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
2020-09-14 09:19:19 +00:00
Ziye Yang
a6db2f3590 sock: enable placement_id configuration in sock layer
This patch is used to enable placement_id getting
in sock layer and also add the rpc support.

Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Change-Id: I70de57b0ed392a0aefce9d3ff1f61ef924015a87
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4146
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-09-11 10:04:22 +00:00
Shuhei Matsumoto
9c1d648315 lib/nvmf: Add nvmf_subsystem_get_listeners RPC
Add an new RPC, nvmf_subsystem_get_listeners.

ANA state is per listener and per subsystem, and is stored in
subsystem listener. We can return ANA state by the existing
nvmf_get_subsystems RPC but it's confusing that listen addresses
have ANA states.

To change ANA state, we will provide a RPC to change ANA state of
only one selected subsystem listener.

To query ANA state, it will be convenient to get ANA states of all
listeners of one selected subsystem.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ic3baad6eac65d7af6e0cab2c4059e1458d41e6e2
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4059
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-09-09 07:20:16 +00:00
Shuhei Matsumoto
83eb352b3c lib/nvmf: Add nvmf_subsystem_get_qpairs RPC
Add an new RPC, nvmf_subsystem_get_qpairs to retrieve the list of
qpairs of an NVMe-oF subsystem.

This RPC will be usable to verify if NVMe ANA works.

Pause and resume the subsystem to access the qpairs safely.

One subtle issue remains. The JSON RPC returns success even if
resuming the subsystem fails. Write FIXME to address this.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I9d90a01b1117dee00d85b2e21b4f4d02d80db531
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4050
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-09-09 07:20:16 +00:00
JimboLuCN
dd3d5800b0 script/rpc: fix bdev_set_qos_limit's usage error
Signed-off-by: JimboLuCN <jimbolucn@gmail.com>
Change-Id: I67db5c7ef81ae77edefcc5ecf058826d3be8d2e8
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3981
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-09-01 07:51:38 +00:00
Vitaliy Mysak
d267d0e874 lib/log: add RPC to toggle timestamps
Allow toggling log timestamps on and off by adding new RPC call.

Change-Id: I34c84bf89fae352ade266fbf7fd20594ff67bced
Signed-off-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/2024
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2020-08-31 07:46:36 +00:00
Shuhei Matsumoto
1da94ed7b8 rpc/nvmf: Add ana_reporting parameter to nvmf_create_subsystem RPC
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I9adc8373050e68872a4d9e89518c137e61005254
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3852
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-08-21 08:22:40 +00:00
Shuhei Matsumoto
4cc04a1251 lib/nvmf: Add nvmf_subsystem_get_controllers RPC
Add an new RPC, nvmf_subsystem_get_controllers to retrieve the list
of NVMe-oF controllers of an NVMe-oF subsystem.

One of the main use cases will be to get identification information
of NVMe-oF controllers to configure their ANA states dynamically.

Pause and resume the subsystem to access the controllers safely.

One subtle issue remains. The JSON RPC returns success even if
resuming the subsystem fails. Write FIXME explicitly to address this.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ibf8d1cf56850a705e343b86022d101b4c7204199
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3848
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-08-21 08:22:40 +00:00
yupeng
2d30df9b0b bdev: add bdev_examine_bdev API
The bdev_examine_bdev api will examine a bdev explicitly. After
disabling the auto_examine feature, a user could call
bdev_examine_bdev to examine a specific bdev he/she wants.

Signed-off-by: Peng Yu <yupeng0921@gmail.com>
Change-Id: Ifbbfb6f667287669ddf6175b8208efee39762933
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3219
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Michael Haeuptle <michaelhaeuptle@gmail.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-08-20 08:56:53 +00:00
Shuhei Matsumoto
05cd697757 lib/iscsi: Add MaxR2TPerConnection to iSCSI options
Add MaxR2TPerConnection to iSCSI global options and make it configurable
by JSON RPC.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ida95e5c7dac301a22520656709e1aa4d611f31ef
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3777
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-08-18 07:27:45 +00:00
Shuhei Matsumoto
5aaf754f81 lib/iscsi: Add MaxLargeDataInPerConnection to iSCSI options
Add MaxLargeDataInPerConnection to iSCSI global options and make
it configurable by JSON RPC.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ibcd16da2eac64241217bedeb89a7929bbdc67871
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3756
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-08-18 07:27:45 +00:00
Shuhei Matsumoto
e97fd6c936 lib/iscsi: Add iscsi_target_node_request_logout RPC
For the login redirection feature, the current implementation works
only if a portal is redirected from an initial portal to a redirect
portal. However, the login redirection feature should work even if a
portal is redirected from one redirect portal to another redirect
portal.

A public portal group knows only a redirect portal and does not know
the portal group of the redirect portal.

Moreover, it is very likely that an initial portal and a redirect portal
exist in different SPDK iSCSI target applications.

To cover all these concerns, add an new iscsi_target_node_request_logout
RPC to request connections whose portal group tag match for the target
node.

To cover potential use cases, make the second parameter portal group
tag optional.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I612672490722fb22fd4eba055998b7408ab84ca5
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3780
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-08-17 08:26:59 +00:00
Shuhei Matsumoto
8cf5581fa9 lib/iscsi: Remove async logout request from iscsi_target_node_redirect()
As written in doc/iscsi.md, typically the login redirection feature
will be used in scale out iSCSI target system, which runs multiple
SPDK iSCSI target applications.

In scale out iSCSI target system, the initial portal, the current
redirect portal, and the next redirect portal are likely to be in
different SPDK iSCSI target applications.

In this case, asynchronous logout request should be sent independently
from the iSCSI target application which has the current redirect portal.

However, we had added asynchronous logout request into the iSCSI target
application which has the next redirect portal. This idea works only
for the case that login is redirected from the initial portal to a
redirect portal.

We remove asynchronous logout request from iscsi_target_node_redirect()
in this patch, and update the corresponding help documents.

The next patch will add an new RPC to send asynchronous logout
request to all connections to the specified portal group and the
specified target.

Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: Ib0ac72e8cdad7e8c64e446b7495e572fac4b5bae
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3779
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2020-08-17 08:26:59 +00:00
rafalste
4d91b4ef01 bdev/ocf: add cache line size
Define cache line size when creating cache device.

Signed-off-by: rafalste <rafal.stefanowski@intel.com>
Change-Id: Ica536a9bda35c355b4dd4e406a241defc1453f53
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3449
Community-CI: Mellanox Build Bot
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2020-08-12 10:39:56 +00:00
Seth Howell
8bff48f63c module/bdev_rpc: modify detach_ctrlr rpc to accept trid.
This will allow us to use this RPC to detach only specific
paths from controllers.

Signed-off-by: Seth Howell <seth.howell@intel.com>
Change-Id: Ib52e38aa7d4ea096418a6dc0328481c2e8db6c54
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3070
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2020-08-11 08:29:14 +00:00