This was a parameter on the nvmf_create_transport
RPC, and was replaced with max_io_qpairs_per_ctrlr to
reduce confusion on whether this number included the
admin queue or not.
nvmf_vhost test was using this deprecated parameter.
Change it to use -m (max_io_qpairs_per_ctrlr)
instead. '-p 4' would have been evaluated as 1 admin
queue + 3 I/O queues, but it's likely the intent
was for 4 I/O queues. This is a perfect example of
why this parameter was deprecated.
For reference, this was deprecated in June 2020,
commit 1551197db.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I4364fc0a76c9993b376932b6eea243d7cefca9cd
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11543
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Batch support has been removed from both the accel_fw and idxd
public API so remove the supporting docs.
Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: I98d1ab7a80942ef69a824482beb76cf921bc3d7f
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11379
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
The htmlonly element that uses javascript to draw a diagram hinders
readability of the document in typical terminal-based editors, on
github/gitlab, etc. Not even the official documentation at
https://spdk.io/doc/blob.html renders it, at least in part because
Two.js is not present.
ASCII art can easily convey the same information in a much more
accessible way.
Signed-off-by: Mike Gerdts <mgerdts@nvidia.com>
Change-Id: I5779d4639b1bee8a976d915d6853f11b05a35b71
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11269
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Provides RPCs for the qpair error injection APIs to bdev_nvme.
These RPCs are useful in testing NVMeoF/NVMe behavior for various
error scenarios in production.
Signed-off-by: Michael Haeuptle <michael.haeuptle@hpe.com>
Change-Id: I0db7995d7a712d4f8a60e643d564faa6908c3a55
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10992
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
It may take a long time to detect network transport error
when e.g. port is removed on remote target. This timeout
depends on 2 parameters - retry_count and ack_timeout.
bdev_nvme_set_options supports configuration of retry_count
but transport_ack_timeout is missed. Note: this parameter
is used by RDMA transport only.
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Change-Id: I7c3090dc8e4078f64d444e2392a9e0a6ecdc31c0
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11175
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-by: <tanl12@chinatelecom.cn>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
The driver still may use batches to implement some operations or for
efficiency reasons.
Batching my be resurrected in the future, but for now we need to do some
fairly extensive performance changes on the driver and eliminating all
of this unused/inactive code makes that much easier.
Change-Id: I92fcec9e4c7424771f053123d821cc57dba9793c
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10348
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
If ctrlr_loss_timeout_sec is set to -1, reconnect is tried repeatedly
indefinitely, and I/Os continue to be queued.
This patch adds another option fast_io_fail_timeout_sec, a flag
fast_io_fail_timedout to nvme_ctrlr.
If the time fast_io_fail_timeout_sec passed after starting reset,
set fast_io_fail_timedout to true not to use the path for I/O submission.
fast_io_fail_timeout_sec is initialized to zero as same as
ctrlr_loss_timeout_sec and reconnect_delay_sec.
The name of the parameter follows the famous DM-multipath, its fast_io_fail_tmo.
Change-Id: Ib870cf8e2fd29300c47f1df69617776f4e67bd8c
Signed-off-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10301
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Previously reconnect retry was not controlled and was repeated indefinitely.
This patch adds two options, ctrlr_loss_timeout_sec and reconnect_delay_sec,
to nvme_ctrlr and add reset_start_tsc, reconnect_is_delayed, and
reconnect_delay_timer to nvme_ctrlr to control reconnect retry.
Both of ctrlr_loss_timeout_sec and reconnect_delay_sec are initialized to
zero. This means reconnect is not throttled as we did before this patch.
A few more changes are added.
Change nvme_io_path_is_failed() to return false if reset is throttled
even if nvme_ctrlr is reseting or is to be reconnected.
spdk_nvme_ctrlr_reconnect_poll_async() may continue returning -EAGAIN
infinitely. To check out such exceptional case, use ctrlr_loss_timeout_sec.
Not only ctrlr reset but also non-multipath ctrlr failover is controlled.
So we need to include path failover into ctrlr reconnect.
When the active path is removed and switched to one of the alternative paths,
if ctrlr reconnect is scheduled, connecting to the alternative path is left
to the scheduled reconnect.
If reset or reconnect ctrlr is failed and the retry is scheduled,
switch the active path to one of alternative paths.
Restore unit test cases removed in the previous patches.
Change-Id: Idec636c4eced39eb47ff4ef6fde72d6fd9fe4f85
Signed-off-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10128
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Monica Kenguva <monica.kenguva@intel.com>
In project practice, config_file and key_file are often used to connect
to a rados cluster, config_file includes "mon_host" and other rados
configurations like "rbd_cache", and key_file includes the secret key
and the access authority to each pool for current user. This patch adds
key_file option, user can specify config_file and key_file or only config_param
to connect rados cluster. This will make it much more flexible for users with
his/her convenience.
Signed-off-by: Tan Long <tanl12@chinatelecom.cn>
Change-Id: I6b49aad70b578bdeb3ac8ea9ca0fcbd931582025
Signed-off-by: Tan Long <tanl12@chinatelecom.cn>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10485
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: GangCao <gang.cao@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Xiaodong Liu <xiaodong.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Add support to enable individual traces through rpc commands
and modify jsonrpc.md to describe the changes.
Change-Id: I3664fc28f1c25a76eade4cff0a0ab1870172f8de
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10518
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
This RPC will stop the specified discovery service,
including detaching from any controllers that were
attached as part of that discovery service.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I9222876457fc45e1acde680a7bd1925917c22308
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10832
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
This patch adds the framework for a discovery
service in the bdev/nvme module.
Users can specify an IP/port of a discovery service.
The bdev/nvme module will connect to a discovery
controller, get the discovery log page, and then
register for AERs. It will connect to each
subsystem specified in the initial log page.
AER completions will trigger fetching the log
page again, at which point new subsystems will
be connected to, or removed subsystems will be
detached.
This patch does the following:
* Adds the new start_discovery RPC
* Connects to the discovery controller
* Gets the discovery log page
* Registers for AERs
* Detach from discovery controllers at shutdown
Subsequent patches in this series will:
* Connect to subsystems listed in discovery log page
* Detach from subsystems that were listed in earlier
discovery log pages but subsequently removed
* Add a stop_discovery RPC
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I54bfa896a48c5619676f156b5ea9f2d1f886c72f
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10694
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
It makes it possible for the user to specify whether a transport should
try to use zero-copy to execute requests when possible.
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Change-Id: I40a92b0d7a6707f4c9292795f380846acb227200
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10780
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Signed-off-by: Michal Berger <michalx.berger@intel.com>
Change-Id: Ia89ca218681144147eb196cdec67b6e6c19a97b4
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/8546
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
This patch modifies documentation page to explain
changes introduced in the previous patch.
Change-Id: If95250004bf8642c941a32a8805e437d6f6c5004
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10501
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
This -o parameter is required. I think -s 4096 is a very old version.
Now the definition is different.
Change-Id: I0e12fae51a2f092d0896c95e0c128754b430354e
Signed-off-by: wanghailiangx <hailiangx.e.wang@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10820
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
We already uses vfio-user instead.
Change-Id: Ic565554cc124fe34304c3f9dbadbf01723ddf900
Signed-off-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10634
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
This RPC lists all PCI devices attached to an SPDK application. Each
device is identified by a BDF and contains a buffer with a copy of its
config space.
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Change-Id: I852f421fde105d975458f8e63b8da4f92ed2c69b
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10652
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Community-CI: Mellanox Build Bot
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Change-Id: Ic65537768811f98370509b47a0e7b80dee60e032
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10486
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Maciej Wawryk <maciejx.wawryk@intel.com>
Reviewed-by: Pawel Piatek <pawelx.piatek@intel.com>
Reviewed-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-by: Michal Berger <michalx.berger@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
This patch enables WARN_NO_PARAMDOC in Doxygen and
resolves remaining issues.
Void return type does not require documentation.
Some of the removed docs were not even Doxygen type
comment, see lack of '\'.
Fixed errors were similar to below:
spdk/include/spdk/nvmf.h:1081: warning: documented empty return type of spdk_nvmf_tgt_add_transport
Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Change-Id: I6bb282ead8dc918885f7a89ab8829e4f5c477247
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10387
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Dong Yi <dongx.yi@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Resolves issue below
spdk/doc/accel_fw.md:111: error: explicit link request to 'accel_idxd_kernel' could not be resolved
Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Change-Id: I5bf205706a43887e0cac0bcc5b8c5de1dc67e7f3
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10385
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Change-Id: I723526e80b5b491945b90f0baccda2a3fcc4fb03
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10309
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Allow to specify optimal IO boundary for
malloc bdev, it can be used to test split
of IO requests on generic bdev layer
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Change-Id: Ic3529dc00cf852ea5cf40d0553d846a698fff6c7
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10068
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Issue: spdk_top tracked pollers by the poller name string and the
thread_id they are running on. This shows incorrect stats when
multiple pollers exist on the same thread with the same name.
Solution: Added a unique poller id for each poller on a thread and
to allow spdk_top to track pollers by thread_id and poller_id.
Signed-off-by: Michael Piszczek <mpiszczek@ddn.com>
Change-Id: I1879e2afc9a929d1df9e8e35510f0092c5443bdc
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5868
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Add bdev_retry_count to spdk_bdev_nvme_opts and retry_count to
nvme_bdev_io, respectively.
Set type of both to int because we want use -1 for infinite retry.
Set the default value of bdev_retry_count to zero for the backward
compatibility.
bdev_retry_count is configurable by the RPC bdev_nvme_set_options.
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I9bc746fcea54aa8722c76f79c70c2ae2b375aa53
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9864
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
retry_count of struct spdk_bdev_nvme_opts controls the number of retries
in the transport layer, and is set to transport_retry_count of struct
spdk_nvme_ctrlr_opts.
The next patch will add bdev_retry_count to struct spdk_bdev_nvme_opts
to control the number of retries in the bdev layer.
For clarification, rename retry_count to transport_retry_count of
struct spdk_bdev_nvme_opts. Then deprecate the retry_count parameter
and add and use an new parameter transport_retry_count instead for
the RPC bdev_nvme_set_options.
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I0689c54aa1c96ee99d24236e8ff1a594ad7208e4
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9924
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
SPDK nvmf target reports all listeners on all subsystems
in discovery pages, kernel target reports only subsystems
listening on a port where discovery command is received.
NVMEoF specification allows to specify any addresses/
transport types. Ch 5: The set of Discovery Log entries should
include all applicable addresses on the same fabric as the
Discovery Service and may include addresses on other fabrics.
To align SPDK and kernel targets behaviour, add filtering
rules to allow flexible configuration of what should be
listed in discovery log page entries.
Fixes#2082
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Change-Id: Ie981edebb29206793d3310940034dcbb22c52441
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9185
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
You can now detach specific paths based on the host parameters. This is
useful for two paths to the same target that use different local NICs.
Change-Id: I4858bfda7d940052ca77ffb0bbe764a688fb315d
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9827
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
This patch is to solve the issue that two nvmf target connect the same rbd image and used for multipath.
The scenario is host wants to access the same rbd image via two gateways, host and gateways are working as nvmf ini and tgt, and two gateways connect with the rbd image, io can switch to another gateway once one is broken. The targets of multipath must have the same uuid, so this patch add a new argument for bdev_rbd_create, like malloc dev.
Signed-off-by: tanlong <948985618@qq.com>
Change-Id: I593fedb6c5d94f625f1b331fdc40e2db488f7fb7
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9935
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
This patch is used to update the accel_fw in order to
add more details about using the kernel idxd driver to
drive DSA devices.
Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Change-Id: I7358e601492bd8f88c84505c14062ee6dce42d6f
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9206
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: GangCao <gang.cao@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
This parameter may have the values "disable" or "failover". The default
is failover to match existing behavior. In the future we expect to
change the default behavior to disable.
Further, we expect to add an "enable" option soon to do full multipath.
Change-Id: Iebbdc9b95f23101f18d64e085933463498e627be
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9343
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Prior a regular round robin could result in strange performance
if an idxd device from another socket was used.
Signed-off-by: peluse <peluse@localhost.localdomain>
Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Change-Id: Id863c79067beabe73ef89d92b3fb3c436821b97a
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9367
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Monica Kenguva <monica.kenguva@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Similar is already done for json-rpc bdev_get_bdevs, it might be
useful for the upper layer which has no interest in all but only
in one specified.
Signed-off-by: Jacek Kalwas <jacek.kalwas@intel.com>
Change-Id: Ie1af1cb4778edd265914bbfdc2777f66c6c76572
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9362
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Signed-off-by: John Levon <john.levon@nutanix.com>
Change-Id: Ifa8e80e0a25af7757181f480ab0405ec902a61ff
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9596
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Signed-off-by: John Levon <john.levon@nutanix.com>
Change-Id: I5c0fc5966d1ed9c78e83bd6772191d46bde1331c
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9595
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Change-Id: I67728508bc6797dd38b5c8c9d836538be1989d8b
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9586
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Signed-off-by: Michal Berger <michalx.berger@intel.com>
Change-Id: I9efbb1928e1935ec55edbdb23a6ad99772b1e6ae
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9522
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Signed-off-by: John Levon <john.levon@nutanix.com>
Change-Id: I1404de46415f485f0f16311442f27135207f157a
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9462
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Dong Yi <dongx.yi@intel.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
MD040 - Fenced code blocks should have a language specified
Fixed all errors
Signed-off-by: Maciej Wawryk <maciejx.wawryk@intel.com>
Change-Id: Iddd307068c1047ca9a0bb12c1b0d9c88f496765f
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9272
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
NVMe over Fabrics target page mentions nvmf traces, but nvmf traces
page does not link the nvmf target guide - the need to configure
target using our guide is obvious, if user follows the guide and
then enters the traces page. However, if user lands on traces page
first, the need to configure target first is not clearly communicated.
Change-Id: If4aef1a8d061acb436ca77c3308e8dda0ab340cf
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9345
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>