This patch shows UUID and base bdev for logical volume stores
when get_lvol_stores() RPC is called.
Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Change-Id: Idbd0bc6c4a0334e5af8d4a674a203ddb2270f3e4
Reviewed-on: https://review.gerrithub.io/374604
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Maciej Szwed <maciej.szwed@intel.com>
Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com>
Change-Id: Ia96ae78ff9530d953181ac5f7255a38f3c8ec430
Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Signed-off-by: Maciej Szwed <maciej.szwed@intel.com>
Signed-off-by: Piotr Pelplinski <piotr.pelplinski@intel.com>
Reviewed-on: https://review.gerrithub.io/375392
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
The nvmf library now supports the ability to assign arbitrary NSIDs,
rather than automatically assigning the next one in line. Expose this
functionality to the user via the configuration file and RPC interfaces.
Change-Id: Ia85a9a6dfe31a2cd0605c7a6c098eec0c1b7de68
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Reviewed-on: https://review.gerrithub.io/376463
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
The previous behavior with an empty host NQN whitelist was to allow any
host to connect.
Change-Id: I5401e52d96642cf20afe0d50c692613e67262edf
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Reviewed-on: https://review.gerrithub.io/376432
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
This allows the user to enable/disable getrusage() monitoring at
runtime.
Also change the log level to INFO and enable the monitoring in all
builds, not just #ifdef DEBUG.
Change-Id: I2f5c3bc8cd83dcb2a72dc7078bf2cb43aa28827c
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Reviewed-on: https://review.gerrithub.io/376473
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Cunyin Chang <cunyin.chang@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
The construct_aio_bdev RPC still accepts "fname" for backwards
compatibility.
Change-Id: Ibf44f5f3667c6de4b827f7f3f8787aff0a6c4fc9
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Reviewed-on: https://review.gerrithub.io/373834
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Add a file-backed AIO bdev to test it out.
Change-Id: Ifdf206bbdf6cae9379fdc02c80755e96a7198bce
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Reviewed-on: https://review.gerrithub.io/373673
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
There is now only virtual mode. Virtual mode has been
improved enough to reach feature parity with direct
mode and performance benchmarks show no degradation.
Simplify the code by always using virtual mode.
Change-Id: Id5cdb5d4d8c54e661b245ed7250c2f9d66ca2152
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.gerrithub.io/369496
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com>
Change-Id: I93690c923feb1a78e88dd5b9d69d9e8e24fd6034
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Reviewed-on: https://review.gerrithub.io/370560
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
-Add a configuration option: Read-only flag
Vhost block controller can be set in read-only mode.
Option can be enabled in config file or in RPC call:
'construct_vhost_block_controllerr' with '-r' option
Change-Id: I7e58243be00d33bc04120d573fd4ed7775bb9b2c
Signed-off-by: Pawel Niedzwiecki <pawelx.niedzwiecki@intel.com>
Reviewed-on: https://review.gerrithub.io/366086
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Use "trtype" to represent transport types in nvmf_tgt RPCs for
consistency with the NVMe-oF spec and other SPDK RPCs.
The current "transport" names are still supported for compatibility with
existing RPC users.
Change-Id: Ib03dda384dc01a41a18c06c56baff16b82d36c00
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Reviewed-on: https://review.gerrithub.io/367422
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Added new rpc commands together with underlying vhost API and tests.
Change-Id: Ib9c6a530d0909193ea5115aaac4920c44f39613c
Signed-off-by: Dariusz Stojaczyk <dariuszx.stojaczyk@intel.com>
Also change the discovery/nvmf.sh test to use it.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I56bce9a84bd46f13b6d4f34da81abf23413f2598
The user now must choose the name for each AIO bdev. This
provides consistency for names across restarts.
Change-Id: I13ced1d02bb28c51d314512d60f739499b0c7d8d
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Names for the NVMe bdevs are now assigned by the user.
This means the same name will always be assigned to the
same device, even across restarts.
Change-Id: If9825ec9abcb5236b4671bc44a825e4f0d704fe3
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Move claimed flag to struct spdk_scsi_lun and remove RPC call that allow
SCSI LUN to be deleted by user.
Change-Id: I0fe57d33ab017816ab4799bce259807735e0c783
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
This patch adds a library, application and test scripts for extending
SPDK to present virtio-scsi controllers to QEMU-based VMs and
process I/O submitted to devices attached to those controllers.
This functionality is dependent on QEMU patches to enable
vhost-scsi in userspace - those patches are currently working their
way through the QEMU mailing list, but temporary patches to enable
this functionality in QEMU will be made available shortly through the
SPDK github repository.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Signed-off-by: Krzysztof Jakimiak <krzysztof.jakimiak@intel.com>
Signed-off-by: Michal Kosciowski <michal.kosciowski@intel.com>
Signed-off-by: Karol Latecki <karolx.latecki@intel.com>
Signed-off-by: Piotr Pelplinski <piotr.pelplinski@intel.com>
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Signed-off-by: Krzysztof Jakimiak <krzysztof.jakimiak@intel.com>
Change-Id: I138e4021f0ac4b1cd9a6e4041783cdf06e6f0efb
Instance ID is too overloaded and the uses are beginning
to conflict. Separate the RPC configuration out.
Change-Id: I712731130339fee4fc8de4dc2d0fea7040773c58
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Add new commands:
get_vhost_scsi_controllers
construct_vhost_scsi_controller
add_vhost_scsi_lun
These RPC commands are in preparation for an upcoming SPDK vhost-scsi
target.
Change-Id: I8dc3045f832df76a34c55f41dba213d480a3e5fe
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Add an RPC interface to list all blockdevs and their properties.
Change-Id: I50db730d5eff8cffcbe8fe5df6b3461457e8581e
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Rename the construct_rbd_bdev "size" parameter to block_size so that it
is consistent with other bdev construct RPCs.
Change-Id: I88f8ed35444495ffce9550dc224fbcbd58231787
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Leading and trailing whitespace will otherwise lead to empty array
elements, which are not intended.
Change-Id: Ie7bd5dfce8cb9904090a06491d0bde4905de1e3a
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
When creating a bdev via the RPC interface, there was no way to know
what name it was assigned (other than predicting it based on the
numbering scheme). Change all of the relevant RPC interfaces to return
an array of bdev names so they can be used to construct LUNs/subsystems
dynamically in scripts.
Change-Id: I8e03349bdc81afd3d69247396a20df5fcf050f40
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Also continue checking for errors after a problem has been found.
Change-Id: Iea37311e54f68fb6ba8c804ad4b2fb92d5238f36
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Extend the check added in commit
7552ee5512 ("nvmf_tgt: fail if NVMe
controller is not found") to the RPC interface.
Also remove the default PCI address from rpc.py, since it is not a
useful default - the user must specify a PCI address, which will vary
depending on the configuration of the machine.
Change-Id: If9a4e19ef2a84c9d839b467abc011046613f7168
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Instead of a magical "All" value for allowing all hosts, allow the
caller of construct_nvmf_subsystem to omit the "hosts" parameter.
Change-Id: I97c7ae806a0be7142fb59708d47023e42e127fcc
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
create_nvmf_subsystem should not allow the user to specify any
namespaces in direct mode.
Also remove the default Malloc0 namespace in rpc.py; the user
should be required to specify the list in virtual mode.
Change-Id: I3aaf7c64b9ceee89a3f7db15760a669527adb29d
Signed-off-by: Daniel Verkamp <daniel.verkamp@intel.com>
Similar to our NVMf target, this is an iSCSI target that
can interoperate with the Linux and Windows standard iSCSI
initiators.
Change-Id: I6961c5ef99f7b161c396330ed5b543ea29b0ca7b
Signed-off-by: Ben Walker <benjamin.walker@intel.com>