In project practice, config_file and key_file are often used to connect
to a rados cluster, config_file includes "mon_host" and other rados
configurations like "rbd_cache", and key_file includes the secret key
and the access authority to each pool for current user. This patch adds
key_file option, user can specify config_file and key_file or only config_param
to connect rados cluster. This will make it much more flexible for users with
his/her convenience.
Signed-off-by: Tan Long <tanl12@chinatelecom.cn>
Change-Id: I6b49aad70b578bdeb3ac8ea9ca0fcbd931582025
Signed-off-by: Tan Long <tanl12@chinatelecom.cn>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10485
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: GangCao <gang.cao@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Xiaodong Liu <xiaodong.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Add support to enable individual traces through rpc commands
and modify jsonrpc.md to describe the changes.
Change-Id: I3664fc28f1c25a76eade4cff0a0ab1870172f8de
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10518
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
This RPC will stop the specified discovery service,
including detaching from any controllers that were
attached as part of that discovery service.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I9222876457fc45e1acde680a7bd1925917c22308
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10832
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
This patch adds the framework for a discovery
service in the bdev/nvme module.
Users can specify an IP/port of a discovery service.
The bdev/nvme module will connect to a discovery
controller, get the discovery log page, and then
register for AERs. It will connect to each
subsystem specified in the initial log page.
AER completions will trigger fetching the log
page again, at which point new subsystems will
be connected to, or removed subsystems will be
detached.
This patch does the following:
* Adds the new start_discovery RPC
* Connects to the discovery controller
* Gets the discovery log page
* Registers for AERs
* Detach from discovery controllers at shutdown
Subsequent patches in this series will:
* Connect to subsystems listed in discovery log page
* Detach from subsystems that were listed in earlier
discovery log pages but subsequently removed
* Add a stop_discovery RPC
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I54bfa896a48c5619676f156b5ea9f2d1f886c72f
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10694
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
It makes it possible for the user to specify whether a transport should
try to use zero-copy to execute requests when possible.
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Change-Id: I40a92b0d7a6707f4c9292795f380846acb227200
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10780
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Not every transport requires accept poller - transport specific
layer can have its own policy and way of handling new connection.
APIs to notify generic layer are already in place
- spdk_nvmf_poll_group_add
- spdk_nvmf_tgt_new_qpair
Having accept poller removed should simplify interrupt mode impl
in transport specific layer.
Fixes issue #1876
Change-Id: Ia6cac0c2da67a298e88956734c50fb6e6b7521f1
Signed-off-by: Jacek Kalwas <jacek.kalwas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7268
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
This RPC lists all PCI devices attached to an SPDK application. Each
device is identified by a BDF and contains a buffer with a copy of its
config space.
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Change-Id: I852f421fde105d975458f8e63b8da4f92ed2c69b
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10652
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Community-CI: Mellanox Build Bot
We provided list of IP addresses as the example of the list of the
initiator names of the iscsi_create_initiator_group and
iscsi_initiator_group_add_initiators RPCs.
However, they were very confusing and gave little hint about how
to use initiator name.
Fix them by providing IQNs instead.
Fixes issue #2209
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I8ce19c4ed0af54fd8a6f1ab2a74b2e6f865d3d1c
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10236
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Allow to specify optimal IO boundary for
malloc bdev, it can be used to test split
of IO requests on generic bdev layer
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Change-Id: Ic3529dc00cf852ea5cf40d0553d846a698fff6c7
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10068
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
If trsvcid is not set in the nvmf_subsystem_remove_listener call,
rpc client treats it as 'None' and sends "null" to the application,
which causes decode failure in SPDK.
Trsvcid is described as optional and should be treated this way.
For such a listener removal call with an empty trsvcid, "" should be
sent as trsvcid instead of "null" in the json request.
Signed-off-by: Blachut, Bartosz <bartosz.blachut@intel.com>
Change-Id: Ic26907c22a2600c9618354ce8ff63e93e00aec09
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9659
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jacek Kalwas <jacek.kalwas@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Add bdev_retry_count to spdk_bdev_nvme_opts and retry_count to
nvme_bdev_io, respectively.
Set type of both to int because we want use -1 for infinite retry.
Set the default value of bdev_retry_count to zero for the backward
compatibility.
bdev_retry_count is configurable by the RPC bdev_nvme_set_options.
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I9bc746fcea54aa8722c76f79c70c2ae2b375aa53
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9864
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
retry_count of struct spdk_bdev_nvme_opts controls the number of retries
in the transport layer, and is set to transport_retry_count of struct
spdk_nvme_ctrlr_opts.
The next patch will add bdev_retry_count to struct spdk_bdev_nvme_opts
to control the number of retries in the bdev layer.
For clarification, rename retry_count to transport_retry_count of
struct spdk_bdev_nvme_opts. Then deprecate the retry_count parameter
and add and use an new parameter transport_retry_count instead for
the RPC bdev_nvme_set_options.
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I0689c54aa1c96ee99d24236e8ff1a594ad7208e4
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9924
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
SPDK nvmf target reports all listeners on all subsystems
in discovery pages, kernel target reports only subsystems
listening on a port where discovery command is received.
NVMEoF specification allows to specify any addresses/
transport types. Ch 5: The set of Discovery Log entries should
include all applicable addresses on the same fabric as the
Discovery Service and may include addresses on other fabrics.
To align SPDK and kernel targets behaviour, add filtering
rules to allow flexible configuration of what should be
listed in discovery log page entries.
Fixes#2082
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Change-Id: Ie981edebb29206793d3310940034dcbb22c52441
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9185
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
You can now detach specific paths based on the host parameters. This is
useful for two paths to the same target that use different local NICs.
Change-Id: I4858bfda7d940052ca77ffb0bbe764a688fb315d
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9827
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
This patch is to solve the issue that two nvmf target connect the same rbd image and used for multipath.
The scenario is host wants to access the same rbd image via two gateways, host and gateways are working as nvmf ini and tgt, and two gateways connect with the rbd image, io can switch to another gateway once one is broken. The targets of multipath must have the same uuid, so this patch add a new argument for bdev_rbd_create, like malloc dev.
Signed-off-by: tanlong <948985618@qq.com>
Change-Id: I593fedb6c5d94f625f1b331fdc40e2db488f7fb7
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9935
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
This parameter may have the values "disable" or "failover". The default
is failover to match existing behavior. In the future we expect to
change the default behavior to disable.
Further, we expect to add an "enable" option soon to do full multipath.
Change-Id: Iebbdc9b95f23101f18d64e085933463498e627be
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9343
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Similar is already done for json-rpc bdev_get_bdevs, it might be
useful for the upper layer which has no interest in all but only
in one specified.
Signed-off-by: Jacek Kalwas <jacek.kalwas@intel.com>
Change-Id: Ie1af1cb4778edd265914bbfdc2777f66c6c76572
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9362
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Signed-off-by: John Levon <john.levon@nutanix.com>
Change-Id: Ifa8e80e0a25af7757181f480ab0405ec902a61ff
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9596
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Similar is already done for json-rpc bdev_get_bdevs, it might be
useful for the upper layer which has no interest in all but only
in one specified.
Signed-off-by: Jacek Kalwas <jacek.kalwas@intel.com>
Change-Id: I25f7d20ff953e612d7982207d57607f1c3bbaa90
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9361
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
As far as we're aware, this is not in use by anyone. OCSSD has largely
been replaced by ZNS and no OCSSD drives made it to the market.
Change-Id: I020ee277da5292f8c4777f224acafd87586f8238
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9328
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Dong Yi <dongx.yi@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Parses and verifies hexadecimal cpu bit mask specified by the user.
Added verification to check for cpu cores range, making sure poll groups cores
assigned within the range of cpu cores allocated for the application.
RPC nvmf_set_config now takes an argument to configure ‘poll groups’,
a new parameter for NVMf subsystem. This parameter sets a CPU mask
to spawn threads which run an event loop for a ‘poll group’.
Change-Id: Ied9081c2213715ec94de00a8b37153730b8ac2ed
Signed-off-by: Yuri <yuriy.kirichok@hpe.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5611
Community-CI: Mellanox Build Bot
Reviewed-by: Matt Dumm <matt.dumm@hpe.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
This parameter is still part of API spdk_sock_impl_opts
structure but it is not used. Keep it to support ABI
compatibility since it is located in the middle of the
structure and removing it may break socket opts initialization
or parsing.
Change-Id: Ib641ad7d965d68bc9ebb65dba531408d88cf6fa1
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/8914
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Implement bdev_nvme_reset_controller rpc, which allows the NVMe
controller to be reset over RPC. Implement bdev_nvme_reset_rpc()
which starts the reset of the controller and returns the result of
the controller reset via the callback function after it completes.
Signed-off-by: Jonathan Teh <jonathan.teh@mayadata.io>
Change-Id: Id98d5e56feb315b7e44e9bb5e5f495e9b1cd1de0
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/8456
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
This patch is used to add the support for users to configure
use kernel or userspace idxd library.
Change-Id: Ie159b897bc9595894ad8f333168efaea6c2a3d78
Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7332
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Now that we've deprecated the RPCs for a release, we can remove the whole
library.
Change-Id: I0f1a357fcfb3404efac39aa021928841c2f22ff1
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/4305
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Add three parameters, pdu_pool_size, immediate_data_pool_size, and
data_out_pool_size to the RPC iscsi_set_options to run iSCSI target
with little memory.
For some use cases, we want to keep the max number of connections,
but simultaneously we want to reduce the pool size and let I/Os wait
until resource is provided.
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I74dc785310b1d985f3e338c1e13fba3a3840d113
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/8191
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Purpose: Let the users know the current available registered Rados
cluster and the related info.
Change-Id: I115c129ae6e4b0372579aad168fd88f8be136357
Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7990
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
In case the addr argument was not an existing unix socket file the rpc
client would consider it to be an actual ip address. As a result
connect() would be called with improper set of arguments. This could
cause the rpc.py to block for undesired amount of time until connect()
finally decided to return (seen on some fedora33 builds).
This was affecting sh wrapper functions like waitforlisten() which
use rpc.py to determine if given app is ready to be talk to blocking
execution of the tests for way too long then intendent.
To avoid such a scenario determine the format of the address and use
routines proper for given address family.
Signed-off-by: Michal Berger <michalx.berger@intel.com>
Change-Id: Iaac701d72c772629fa7c6478ff4781b0c5d485d5
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7777
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Revise bdev_rbd_create rpc call to add an optional
parameter "--cluster-name", e.g., "--cluster-name Rados".
Then users can create a rbd bdev with registered
Rados Cluster. This shared strategy can be used to
remove the thread creation overhead if multiple rbds
are connected to the same Ceph cluster.
Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Change-Id: Ide5800f8fc6b2074805272a59731c666fe279b9a
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7584
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
This patch is used to add two rpc calls:
bdev_rbd_register_cluster
bdev_rbd_unregister_cluster
Then in the next patch, rbd bdev constructed on the same cluster object
can share the common Rados_t structure in order to remove the thread creation
overhead and improve the scalability.
Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Change-Id: I898cc4ffabb8e6721ba5bef099cbf948c64d2c98
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7551
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Add {min,max}_cntlid to spdk_nvmf_subsystem, defaulting to 1 and
0xFFEF, respectively, and add nvmf_subsystem_set_cntlid_range() to
allow the controller range to be configured in the range [min_cntlid,
max_cntlid].
Also add {min,max}_cntlid to the nvmf_create_subsystem RPC to allow
the controller ID range to be specified when creating an nvmf
subsystem.
Signed-off-by: Jonathan Teh <jonathan.teh@mayadata.io>
Change-Id: I936db3bb0c9a38569063a6fd3c11df262dfad776
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7322
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
The changes in the nvmf_create_transport show
how this command parser work. And there have
two benefit for this changed.
1. Simplify the definition of rpc method. no need add
so many args anymore. Also it retains its original
functions, so we can also check the input args.
2. Make the rpc call more versatile, for example.
when user extend the subparsers(add new args
into subparsers), they can pass some private args
into the rpc method by command parser.
Signed-off-by: jiaqizho <jiaqi.zhou@intel.com>
Change-Id: Iaf916e3454f23715cf9216794bb80c65b2b4603f
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6652
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
When zcero copy send is enabled and used by initiator,
it could significantly increase latency in some payloads.
To enable more fine graing configuration of zero copy
send feature, add new parameters enable_zerocopy_send_server
and enable_zerocopy_send_client to spdk_sock_impl_opts to
enable/disable zcopy for specific type of sockets.
Exisiting enable_zerocopy_send parameter affects all types
of sockets.
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Change-Id: I111c75608f8826980a56e210c076ab8ff16ddbdc
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7457
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Change-Id: I4ed583d91ae9e820be1ee6f4553f29d6650c4922
Signed-off-by: Jin Yu <jin.yu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5791
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Leverage SO_INCOMING_CPU to get the CPU affinity of connections
(sockets). And allocate the connections to specific poll groups,
which aims to utilize cache locality.
From our test:
6 P4600 NVMe on target,target uses 8 cores, NIC irqs are bound to
these 8 cores, and initiator side uses 24 and 32 cores,
we can get 11%~17% randwrite performance boost for posix, and 8%~12%
for uring.
Change-Id: I011e0a21502c85adcccd4a14fbe9838b43f54976
Signed-off-by: Richael Zhuang <richael.zhuang@arm.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/5748
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
We need to catch the JSONRPCException when we cannot
connect, so that the error message can be printed
more cleanly. Also suggest to the user that maybe
they don't have an SPDK application running when
it cannot connect.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I497bed86573d5bf07a2b48b3d6682a2427aa4987
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6754
Community-CI: Broadcom CI
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Monica Kenguva <monica.kenguva@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>