The e2edp test `dp_with_pract_test` includes code to modify the data
length if the size of metadata is 8 bytes, but fails to set
req->use_extended_lba if we actually need to pass an extended LBA
(md_size > 8).
Similarly, the `dp_guard_check_extended_lba_test` miscalculates the CRC
when md_size is > 8. The CRC must be calculated over both data AND the
first md_size - 8 bytes of metadata.
Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
Change-Id: I5252c1fe02908745d6aa68799859ed85f32e87ec
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6891
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>