numam-spdk/test/nvmf/common.sh
Pawel Wodkowski c0021d08ce test/nvmf: don't use SoftRoCE with bridges
Bridges are not working with SoftRoCE.

Change-Id: I4c600efb3b7bf85386658fd050cd2755dfc542b4
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Reviewed-on: https://review.gerrithub.io/400009
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2018-02-15 11:23:22 -05:00

167 lines
3.1 KiB
Bash
Executable File

#!/usr/bin/env bash
NVMF_PORT=4420
NVMF_IP_PREFIX="192.168.100"
NVMF_IP_LEAST_ADDR=8
if [ -z "$NVMF_APP" ]; then
NVMF_APP=./app/nvmf_tgt/nvmf_tgt
fi
if [ -z "$NVMF_TEST_CORE_MASK" ]; then
NVMF_TEST_CORE_MASK=0xFFFF
fi
function load_ib_rdma_modules()
{
if [ `uname` != Linux ]; then
return 0
fi
modprobe ib_cm
modprobe ib_core
modprobe ib_ucm
modprobe ib_umad
modprobe ib_uverbs
modprobe iw_cm
modprobe rdma_cm
modprobe rdma_ucm
}
function detect_soft_roce_nics()
{
if hash rxe_cfg; then
rxe_cfg start
rdma_nics=$(get_rdma_if_list)
all_nics=$(ifconfig -s | awk '{print $1}')
all_nics=("${all_nics[@]/"Iface"}")
non_rdma_nics=$(echo "$rdma_nics $all_nics" | sort | uniq -u)
for nic in $non_rdma_nics; do
if [[ -d /sys/class/net/${nic}/bridge ]]; then
continue
fi
rxe_cfg add $nic || true
done
fi
}
function detect_mellanox_nics()
{
if ! hash lspci; then
return 0
fi
nvmf_nic_bdfs=`lspci | grep Ethernet | grep Mellanox | awk -F ' ' '{print "0000:"$1}'`
mlx_core_driver="mlx4_core"
mlx_ib_driver="mlx4_ib"
mlx_en_driver="mlx4_en"
if [ -z "$nvmf_nic_bdfs" ]; then
return 0
fi
# for nvmf target loopback test, suppose we only have one type of card.
for nvmf_nic_bdf in $nvmf_nic_bdfs
do
result=`lspci -vvv -s $nvmf_nic_bdf | grep 'Kernel modules' | awk -F ' ' '{print $3}'`
if [ "$result" == "mlx5_core" ]; then
mlx_core_driver="mlx5_core"
mlx_ib_driver="mlx5_ib"
mlx_en_driver=""
fi
break;
done
modprobe $mlx_core_driver
modprobe $mlx_ib_driver
if [ -n "$mlx_en_driver" ]; then
modprobe $mlx_en_driver
fi
# The mlx4 driver takes an extra few seconds to load after modprobe returns,
# otherwise ifconfig operations will do nothing.
sleep 5
}
function detect_rdma_nics()
{
detect_mellanox_nics
detect_soft_roce_nics
}
function allocate_nic_ips()
{
let count=$NVMF_IP_LEAST_ADDR
for nic_name in $(get_rdma_if_list); do
ip="$(get_ip_address $nic_name)"
if [ -z $ip ]; then
ifconfig $nic_name $NVMF_IP_PREFIX.$count netmask 255.255.255.0 up
let count=$count+1
fi
# dump configuration for debug log
ifconfig $nic_name
done
}
function get_available_rdma_ips()
{
for nic_name in $(get_rdma_if_list); do
ifconfig $nic_name | grep "inet " | awk '{print $2}'
done
}
function get_rdma_if_list()
{
for nic_type in `ls /sys/class/infiniband`; do
for nic_name in `ls /sys/class/infiniband/${nic_type}/device/net`; do
echo "$nic_name"
done
done
}
function get_ip_address()
{
interface=$1
ifconfig $interface | grep "inet " | awk '{print $2}' | sed 's/[^0-9\.]//g'
}
function nvmfcleanup()
{
sync
rmmod nvme-rdma
}
function rdma_device_init()
{
load_ib_rdma_modules
detect_rdma_nics
allocate_nic_ips
}
function revert_soft_roce()
{
if hash rxe_cfg; then
interfaces="$(ifconfig -s | awk '{print $1}')"
for interface in $interfaces; do
rxe_cfg remove $interface || true
done
rxe_cfg stop || true
fi
}
function check_ip_is_soft_roce()
{
IP=$1
if hash rxe_cfg; then
dev=$(ip -4 -o addr show | grep $IP | cut -d" " -f2)
if rxe_cfg | grep $dev; then
return 0
else
return 1
fi
else
return 1
fi
}