numam-spdk/test/nvmf/nvmf.sh
Michal Berger 2695854b90 test/nvmf: Add skel for nvmf error testing
The goal of this test is to make sure that proper parts of the lib
fail as they should. These particular tests focus on:

  - spdk_rpc_nvmf_create_subsystem(): model and serial number checks

Change-Id: I504279d08b192d6dfe37a8a601eda44084b596d4
Signed-off-by: Michal Berger <michalx.berger@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/693
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2020-02-27 10:15:40 +00:00

60 lines
2.5 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../..)
source $rootdir/test/common/autotest_common.sh
if [ ! $(uname -s) = Linux ]; then
exit 0
fi
source $rootdir/test/nvmf/common.sh
trap "exit 1" SIGINT SIGTERM EXIT
TEST_ARGS=( "$@" )
run_test "nvmf_example" test/nvmf/target/nvmf_example.sh "${TEST_ARGS[@]}"
run_test "nvmf_filesystem" test/nvmf/target/filesystem.sh "${TEST_ARGS[@]}"
run_test "nvmf_discovery" test/nvmf/target/discovery.sh "${TEST_ARGS[@]}"
run_test "nvmf_connect_disconnect" test/nvmf/target/connect_disconnect.sh "${TEST_ARGS[@]}"
if [ $SPDK_TEST_NVME_CLI -eq 1 ]; then
run_test "nvmf_nvme_cli" test/nvmf/target/nvme_cli.sh "${TEST_ARGS[@]}"
fi
run_test "nvmf_lvol" test/nvmf/target/nvmf_lvol.sh "${TEST_ARGS[@]}"
#TODO: disabled due to intermittent failures. Need to triage.
# run_test "nvmf_srq_overwhelm" test/nvmf/target/srq_overwhelm.sh $TEST_ARGS
run_test "nvmf_vhost" test/nvmf/target/nvmf_vhost.sh "${TEST_ARGS[@]}"
run_test "nvmf_bdev_io_wait" test/nvmf/target/bdev_io_wait.sh "${TEST_ARGS[@]}"
run_test "nvmf_create_transport." test/nvmf/target/create_transport.sh "${TEST_ARGS[@]}"
run_test "nvmf_multitarget" test/nvmf/target/multitarget.sh "${TEST_ARGS[@]}"
if [ $RUN_NIGHTLY -eq 1 ]; then
run_test "nvmf_fuzz" test/nvmf/target/fuzz.sh "${TEST_ARGS[@]}"
run_test "nvmf_multiconnection" test/nvmf/target/multiconnection.sh "${TEST_ARGS[@]}"
run_test "nvmf_initiator_timeout" test/nvmf/target/initiator_timeout.sh "${TEST_ARGS[@]}"
fi
run_test "nvmf_nmic" test/nvmf/target/nmic.sh "${TEST_ARGS[@]}"
run_test "nvmf_rpc" test/nvmf/target/rpc.sh "${TEST_ARGS[@]}"
run_test "nvmf_fio" test/nvmf/target/fio.sh "${TEST_ARGS[@]}"
run_test "nvmf_shutdown" test/nvmf/target/shutdown.sh "${TEST_ARGS[@]}"
run_test "nvmf_bdevio" test/nvmf/target/bdevio.sh "${TEST_ARGS[@]}"
run_test "nvmf_invalid" test/nvmf/target/invalid.sh "${TEST_ARGS[@]}"
timing_enter host
run_test "nvmf_bdevperf" test/nvmf/host/bdevperf.sh "${TEST_ARGS[@]}"
run_test "nvmf_identify" test/nvmf/host/identify.sh "${TEST_ARGS[@]}"
run_test "nvmf_perf" test/nvmf/host/perf.sh "${TEST_ARGS[@]}"
# TODO: disabled due to intermittent failures (RDMA_CM_EVENT_UNREACHABLE/ETIMEDOUT)
#run_test test/nvmf/host/identify_kernel_nvmf.sh $TEST_ARGS
run_test "nvmf_aer" test/nvmf/host/aer.sh "${TEST_ARGS[@]}"
run_test "nvmf_fio" test/nvmf/host/fio.sh "${TEST_ARGS[@]}"
run_test "nvmf_target_disconnect" test/nvmf/host/target_disconnect.sh "${TEST_ARGS[@]}"
timing_exit host
trap - SIGINT SIGTERM EXIT
revert_soft_roce