7b9bd8ac2f
The RPC method create_pmem_pool has been changed to bdev_pmem_create_pool. Change-Id: I8ad1fb98d8e03240a4d982e04e9270cf90e198fc Signed-off-by: wanghailiangx <hailiangx.e.wang@intel.com> Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/8708 Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com> Tested-by: SPDK CI Jenkins <sys_sgci@intel.com> Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com> Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
486 lines
14 KiB
Bash
Executable File
486 lines
14 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
|
|
rootdir=$(readlink -f $(dirname $0)/../..)
|
|
source "$rootdir/test/common/autotest_common.sh"
|
|
source "$rootdir/test/nvmf/common.sh"
|
|
|
|
if [[ $SPDK_TEST_ISCSI -eq 1 ]]; then
|
|
source "$rootdir/test/iscsi_tgt/common.sh"
|
|
fi
|
|
|
|
if [[ $SPDK_TEST_VHOST -ne 1 && $SPDK_TEST_VHOST_INIT -eq 1 ]]; then
|
|
SPDK_TEST_VHOST=1
|
|
echo "WARNING: Virtio initiator JSON_config test requires vhost target."
|
|
echo " Setting SPDK_TEST_VHOST=1 for duration of current script."
|
|
fi
|
|
|
|
if ((SPDK_TEST_BLOCKDEV + \
|
|
SPDK_TEST_ISCSI + \
|
|
SPDK_TEST_NVMF + \
|
|
SPDK_TEST_VHOST + \
|
|
SPDK_TEST_VHOST_INIT + \
|
|
SPDK_TEST_PMDK + \
|
|
SPDK_TEST_RBD == 0)); then
|
|
echo "WARNING: No tests are enabled so not running JSON configuration tests"
|
|
exit 0
|
|
fi
|
|
|
|
declare -A app_pid=([target]="" [initiator]="")
|
|
declare -A app_socket=([target]='/var/tmp/spdk_tgt.sock' [initiator]='/var/tmp/spdk_initiator.sock')
|
|
declare -A app_params=([target]='-m 0x1 -s 1024' [initiator]='-m 0x2 -g -u -s 1024')
|
|
declare -A configs_path=([target]="$rootdir/spdk_tgt_config.json" [initiator]="$rootdir/spdk_initiator_config.json")
|
|
|
|
function tgt_rpc() {
|
|
$rootdir/scripts/rpc.py -s "${app_socket[target]}" "$@"
|
|
}
|
|
|
|
function initiator_rpc() {
|
|
$rootdir/scripts/rpc.py -s "${app_socket[initiator]}" "$@"
|
|
}
|
|
|
|
RE_UUID="[[:alnum:]-]+"
|
|
last_event_id=0
|
|
|
|
function tgt_check_notification_types() {
|
|
timing_enter "${FUNCNAME[0]}"
|
|
|
|
local ret=0
|
|
local enabled_types=("bdev_register" "bdev_unregister")
|
|
|
|
local get_types=($(tgt_rpc notify_get_types | jq -r '.[]'))
|
|
if [[ ${enabled_types[*]} != "${get_types[*]}" ]]; then
|
|
echo "ERROR: expected types: ${enabled_types[*]}, but got: ${get_types[*]}"
|
|
ret=1
|
|
fi
|
|
|
|
timing_exit "${FUNCNAME[0]}"
|
|
return $ret
|
|
}
|
|
|
|
function tgt_check_notifications() {
|
|
local event_line event ev_type ev_ctx
|
|
local rc=""
|
|
|
|
while read -r event_line; do
|
|
# remove ID
|
|
event="${event_line%:*}"
|
|
|
|
ev_type=${event%:*}
|
|
ev_ctx=${event#*:}
|
|
|
|
ex_ev_type=${1%%:*}
|
|
ex_ev_ctx=${1#*:}
|
|
|
|
last_event_id=${event_line##*:}
|
|
|
|
# set rc=false in case of failure so all errors can be printed
|
|
if (($# == 0)); then
|
|
echo "ERROR: got extra event: $event_line"
|
|
rc=false
|
|
continue
|
|
elif ! echo "$ev_type" | grep -E -q "^${ex_ev_type}\$" || ! echo "$ev_ctx" | grep -E -q "^${ex_ev_ctx}\$"; then
|
|
echo "ERROR: expected event '$1' but got '$event' (whole event line: $event_line)"
|
|
rc=false
|
|
fi
|
|
|
|
shift
|
|
done < <(tgt_rpc notify_get_notifications -i ${last_event_id} | jq -r '.[] | "\(.type):\(.ctx):\(.id)"')
|
|
|
|
$rc
|
|
|
|
if (($# != 0)); then
|
|
echo "ERROR: missing events:"
|
|
echo "$@"
|
|
return 1
|
|
fi
|
|
}
|
|
|
|
# $1 - target / initiator
|
|
# $2..$n app parameters
|
|
function json_config_test_start_app() {
|
|
local app=$1
|
|
shift
|
|
|
|
[[ -n "${#app_socket[$app]}" ]] # Check app type
|
|
[[ -z "${app_pid[$app]}" ]] # Assert if app is not running
|
|
|
|
local app_extra_params=""
|
|
if [[ $SPDK_TEST_VHOST -eq 1 || $SPDK_TEST_VHOST_INIT -eq 1 ]]; then
|
|
# If PWD is nfs/sshfs we can't create UNIX sockets there. Always use safe location instead.
|
|
app_extra_params='-S /var/tmp'
|
|
fi
|
|
|
|
$SPDK_BIN_DIR/spdk_tgt ${app_params[$app]} ${app_extra_params} -r ${app_socket[$app]} "$@" &
|
|
app_pid[$app]=$!
|
|
|
|
echo "Waiting for $app to run..."
|
|
waitforlisten ${app_pid[$app]} ${app_socket[$app]}
|
|
echo ""
|
|
}
|
|
|
|
# $1 - target / initiator
|
|
function json_config_test_shutdown_app() {
|
|
local app=$1
|
|
|
|
# Check app type && assert app was started
|
|
[[ -n "${#app_socket[$app]}" ]]
|
|
[[ -n "${app_pid[$app]}" ]]
|
|
|
|
# spdk_kill_instance RPC will trigger ASAN
|
|
kill -SIGINT ${app_pid[$app]}
|
|
|
|
for ((i = 0; i < 30; i++)); do
|
|
if ! kill -0 ${app_pid[$app]} 2> /dev/null; then
|
|
app_pid[$app]=
|
|
break
|
|
fi
|
|
sleep 0.5
|
|
done
|
|
|
|
if [[ -n "${app_pid[$app]}" ]]; then
|
|
echo "SPDK $app shutdown timeout"
|
|
return 1
|
|
fi
|
|
|
|
echo "SPDK $app shutdown done"
|
|
}
|
|
|
|
function create_bdev_subsystem_config() {
|
|
timing_enter "${FUNCNAME[0]}"
|
|
|
|
local expected_notifications=()
|
|
|
|
local event_line event ev_type ev_ctx
|
|
local rc=""
|
|
|
|
# Before testing notifications generated by the operations in this function, we
|
|
# need add existing notification to the expected list first. Otherwise it would fail.
|
|
while read -r event_line; do
|
|
# remove ID
|
|
event="${event_line%:*}"
|
|
ev_type=${event%:*}
|
|
ev_ctx=${event#*:}
|
|
|
|
expected_notifications+=(${ev_type}:${ev_ctx})
|
|
done < <(tgt_rpc notify_get_notifications -i ${last_event_id} | jq -r '.[] | "\(.type):\(.ctx):\(.id)"')
|
|
|
|
if [[ $SPDK_TEST_BLOCKDEV -eq 1 ]]; then
|
|
local lvol_store_base_bdev=Nvme0n1
|
|
if ! tgt_rpc get_bdevs --name ${lvol_store_base_bdev} > /dev/null; then
|
|
if [[ $(uname -s) = Linux ]]; then
|
|
lvol_store_base_bdev=aio_disk
|
|
echo "WARNING: No NVMe drive found. Using '$lvol_store_base_bdev' instead."
|
|
else
|
|
echo "ERROR: No NVMe drive found and bdev_aio is not supported on $(uname -s)."
|
|
timing_exit "${FUNCNAME[0]}"
|
|
return 1
|
|
fi
|
|
fi
|
|
|
|
tgt_rpc bdev_split_create $lvol_store_base_bdev 2
|
|
tgt_rpc bdev_split_create Malloc0 3
|
|
tgt_rpc bdev_malloc_create 8 4096 --name Malloc3
|
|
tgt_rpc bdev_passthru_create -b Malloc3 -p PTBdevFromMalloc3
|
|
|
|
tgt_rpc bdev_null_create Null0 32 512
|
|
|
|
tgt_rpc bdev_malloc_create 32 512 --name Malloc0
|
|
tgt_rpc bdev_malloc_create 16 4096 --name Malloc1
|
|
|
|
expected_notifications+=(
|
|
bdev_register:${lvol_store_base_bdev}p1
|
|
bdev_register:${lvol_store_base_bdev}p0
|
|
bdev_register:Malloc3
|
|
bdev_register:PTBdevFromMalloc3
|
|
bdev_register:Null0
|
|
bdev_register:Malloc0
|
|
bdev_register:Malloc0p2
|
|
bdev_register:Malloc0p1
|
|
bdev_register:Malloc0p0
|
|
bdev_register:Malloc1
|
|
)
|
|
|
|
if [[ $(uname -s) = Linux ]]; then
|
|
# This AIO bdev must be large enough to be used as LVOL store
|
|
dd if=/dev/zero of="$SPDK_TEST_STORAGE/sample_aio" bs=1024 count=102400
|
|
tgt_rpc bdev_aio_create "$SPDK_TEST_STORAGE/sample_aio" aio_disk 1024
|
|
expected_notifications+=(bdev_register:aio_disk)
|
|
fi
|
|
|
|
# For LVOLs use split to check for proper order of initialization.
|
|
# If LVOLs cofniguration will be reordered (eg moved before splits or AIO/NVMe)
|
|
# it should fail loading JSON config from file.
|
|
tgt_rpc bdev_lvol_create_lvstore -c 1048576 ${lvol_store_base_bdev}p0 lvs_test
|
|
tgt_rpc bdev_lvol_create -l lvs_test lvol0 32
|
|
tgt_rpc bdev_lvol_create -l lvs_test -t lvol1 32
|
|
tgt_rpc bdev_lvol_snapshot lvs_test/lvol0 snapshot0
|
|
tgt_rpc bdev_lvol_clone lvs_test/snapshot0 clone0
|
|
|
|
expected_notifications+=(
|
|
"bdev_register:$RE_UUID"
|
|
"bdev_register:$RE_UUID"
|
|
"bdev_register:$RE_UUID"
|
|
"bdev_register:$RE_UUID"
|
|
)
|
|
fi
|
|
|
|
if [[ $SPDK_TEST_CRYPTO -eq 1 ]]; then
|
|
tgt_rpc bdev_malloc_create 8 1024 --name MallocForCryptoBdev
|
|
if [[ $(lspci -d:37c8 | wc -l) -eq 0 ]]; then
|
|
local crypto_dirver=crypto_aesni_mb
|
|
else
|
|
local crypto_dirver=crypto_qat
|
|
fi
|
|
|
|
tgt_rpc bdev_crypto_create MallocForCryptoBdev CryptoMallocBdev $crypto_dirver 0123456789123456
|
|
expected_notifications+=(
|
|
bdev_register:MallocForCryptoBdev
|
|
bdev_register:CryptoMallocBdev
|
|
)
|
|
fi
|
|
|
|
if [[ $SPDK_TEST_PMDK -eq 1 ]]; then
|
|
pmem_pool_file=$(mktemp /tmp/pool_file1.XXXXX)
|
|
rm -f $pmem_pool_file
|
|
tgt_rpc bdev_pmem_create_pool $pmem_pool_file 128 4096
|
|
tgt_rpc bdev_pmem_create -n pmem1 $pmem_pool_file
|
|
expected_notifications+=(bdev_register:pmem1)
|
|
fi
|
|
|
|
if [[ $SPDK_TEST_RBD -eq 1 ]]; then
|
|
rbd_setup 127.0.0.1
|
|
tgt_rpc bdev_rbd_create $RBD_POOL $RBD_NAME 4096
|
|
expected_notifications+=(bdev_register:Ceph0)
|
|
fi
|
|
|
|
tgt_check_notifications "${expected_notifications[@]}"
|
|
|
|
timing_exit "${FUNCNAME[0]}"
|
|
}
|
|
|
|
function cleanup_bdev_subsystem_config() {
|
|
timing_enter "${FUNCNAME[0]}"
|
|
|
|
if [[ $SPDK_TEST_BLOCKDEV -eq 1 ]]; then
|
|
tgt_rpc bdev_lvol_delete lvs_test/clone0
|
|
tgt_rpc bdev_lvol_delete lvs_test/lvol0
|
|
tgt_rpc bdev_lvol_delete lvs_test/snapshot0
|
|
tgt_rpc bdev_lvol_delete_lvstore -l lvs_test
|
|
fi
|
|
|
|
if [[ $(uname -s) = Linux ]]; then
|
|
rm -f "$SPDK_TEST_STORAGE/sample_aio"
|
|
fi
|
|
|
|
if [[ $SPDK_TEST_PMDK -eq 1 && -n "$pmem_pool_file" && -f "$pmem_pool_file" ]]; then
|
|
tgt_rpc bdev_pmem_delete pmem1
|
|
tgt_rpc bdev_pmem_delete_pool $pmem_pool_file
|
|
rm -f $pmem_pool_file
|
|
fi
|
|
|
|
if [[ $SPDK_TEST_RBD -eq 1 ]]; then
|
|
rbd_cleanup
|
|
fi
|
|
|
|
timing_exit "${FUNCNAME[0]}"
|
|
}
|
|
|
|
function create_vhost_subsystem_config() {
|
|
timing_enter "${FUNCNAME[0]}"
|
|
|
|
tgt_rpc bdev_malloc_create 64 1024 --name MallocForVhost0
|
|
tgt_rpc bdev_split_create MallocForVhost0 8
|
|
|
|
tgt_rpc vhost_create_scsi_controller VhostScsiCtrlr0
|
|
tgt_rpc vhost_scsi_controller_add_target VhostScsiCtrlr0 0 MallocForVhost0p3
|
|
tgt_rpc vhost_scsi_controller_add_target VhostScsiCtrlr0 -1 MallocForVhost0p4
|
|
tgt_rpc vhost_controller_set_coalescing VhostScsiCtrlr0 1 100
|
|
|
|
tgt_rpc vhost_create_blk_controller VhostBlkCtrlr0 MallocForVhost0p5
|
|
|
|
timing_exit "${FUNCNAME[0]}"
|
|
}
|
|
|
|
function create_iscsi_subsystem_config() {
|
|
timing_enter "${FUNCNAME[0]}"
|
|
tgt_rpc bdev_malloc_create 64 1024 --name MallocForIscsi0
|
|
tgt_rpc iscsi_create_portal_group $PORTAL_TAG 127.0.0.1:$ISCSI_PORT
|
|
tgt_rpc iscsi_create_initiator_group $INITIATOR_TAG $INITIATOR_NAME $NETMASK
|
|
tgt_rpc iscsi_create_target_node Target3 Target3_alias 'MallocForIscsi0:0' $PORTAL_TAG:$INITIATOR_TAG 64 -d
|
|
timing_exit "${FUNCNAME[0]}"
|
|
}
|
|
|
|
function create_nvmf_subsystem_config() {
|
|
timing_enter "${FUNCNAME[0]}"
|
|
|
|
NVMF_FIRST_TARGET_IP="127.0.0.1"
|
|
if [[ $SPDK_TEST_NVMF_TRANSPORT == "rdma" ]]; then
|
|
rdma_device_init
|
|
NVMF_FIRST_TARGET_IP=$(get_available_rdma_ips | head -n 1)
|
|
fi
|
|
|
|
if [[ -z $NVMF_FIRST_TARGET_IP ]]; then
|
|
echo "Error: no NIC for nvmf test"
|
|
return 1
|
|
fi
|
|
|
|
tgt_rpc bdev_malloc_create 8 512 --name MallocForNvmf0
|
|
tgt_rpc bdev_malloc_create 4 1024 --name MallocForNvmf1
|
|
|
|
tgt_rpc nvmf_create_transport -t $SPDK_TEST_NVMF_TRANSPORT -u 8192 -c 0
|
|
tgt_rpc nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
|
|
tgt_rpc nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 MallocForNvmf0
|
|
tgt_rpc nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 MallocForNvmf1
|
|
tgt_rpc nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $SPDK_TEST_NVMF_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT"
|
|
|
|
timing_exit "${FUNCNAME[0]}"
|
|
}
|
|
|
|
function create_virtio_initiator_config() {
|
|
timing_enter "${FUNCNAME[0]}"
|
|
initiator_rpc bdev_virtio_attach_controller -t user -a /var/tmp/VhostScsiCtrlr0 -d scsi VirtioScsiCtrlr0
|
|
initiator_rpc bdev_virtio_attach_controller -t user -a /var/tmp/VhostBlkCtrlr0 -d blk VirtioBlk0
|
|
timing_exit "${FUNCNAME[0]}"
|
|
}
|
|
|
|
function json_config_test_init() {
|
|
timing_enter "${FUNCNAME[0]}"
|
|
timing_enter json_config_setup_target
|
|
|
|
json_config_test_start_app target --wait-for-rpc
|
|
|
|
#TODO: global subsystem params
|
|
|
|
# Load nvme configuration. The load_config will issue framework_start_init automatically
|
|
(
|
|
$rootdir/scripts/gen_nvme.sh --json-with-subsystems
|
|
) | tgt_rpc load_config
|
|
|
|
tgt_check_notification_types
|
|
|
|
if [[ $SPDK_TEST_BLOCKDEV -eq 1 ]]; then
|
|
create_bdev_subsystem_config
|
|
fi
|
|
|
|
if [[ $SPDK_TEST_VHOST -eq 1 ]]; then
|
|
create_vhost_subsystem_config
|
|
fi
|
|
|
|
if [[ $SPDK_TEST_ISCSI -eq 1 ]]; then
|
|
create_iscsi_subsystem_config
|
|
fi
|
|
|
|
if [[ $SPDK_TEST_NVMF -eq 1 ]]; then
|
|
create_nvmf_subsystem_config
|
|
fi
|
|
timing_exit json_config_setup_target
|
|
|
|
if [[ $SPDK_TEST_VHOST_INIT -eq 1 ]]; then
|
|
json_config_test_start_app initiator
|
|
create_virtio_initiator_config
|
|
fi
|
|
|
|
tgt_rpc bdev_malloc_create 8 512 --name MallocBdevForConfigChangeCheck
|
|
|
|
timing_exit "${FUNCNAME[0]}"
|
|
}
|
|
|
|
function json_config_test_fini() {
|
|
timing_enter "${FUNCNAME[0]}"
|
|
local ret=0
|
|
|
|
if [[ -n "${app_pid[initiator]}" ]]; then
|
|
killprocess ${app_pid[initiator]}
|
|
fi
|
|
|
|
if [[ -n "${app_pid[target]}" ]]; then
|
|
|
|
# Remove any artifacts we created (files, lvol etc)
|
|
cleanup_bdev_subsystem_config
|
|
|
|
# SPDK_TEST_NVMF: Should we clear something?
|
|
killprocess ${app_pid[target]}
|
|
fi
|
|
|
|
rm -f "${configs_path[@]}"
|
|
timing_exit "${FUNCNAME[0]}"
|
|
return $ret
|
|
}
|
|
|
|
function json_config_clear() {
|
|
[[ -n "${#app_socket[$1]}" ]] # Check app type
|
|
$rootdir/test/json_config/clear_config.py -s ${app_socket[$1]} clear_config
|
|
|
|
# Check if config is clean.
|
|
# Global params can't be cleared so need to filter them out.
|
|
local config_filter="$rootdir/test/json_config/config_filter.py"
|
|
|
|
# RPC's used to cleanup configuration (e.g. to delete split and nvme bdevs)
|
|
# complete immediately and they don't wait for the unregister callback.
|
|
# It causes that configuration may not be fully cleaned at this moment and
|
|
# we should to wait a while. (See github issue #789)
|
|
count=100
|
|
while [ $count -gt 0 ]; do
|
|
$rootdir/scripts/rpc.py -s "${app_socket[$1]}" save_config | $config_filter -method delete_global_parameters | $config_filter -method check_empty && break
|
|
count=$((count - 1))
|
|
sleep 0.1
|
|
done
|
|
|
|
if [ $count -eq 0 ]; then
|
|
return 1
|
|
fi
|
|
}
|
|
|
|
on_error_exit() {
|
|
set -x
|
|
set +e
|
|
print_backtrace
|
|
trap - ERR
|
|
echo "Error on $1 - $2"
|
|
json_config_test_fini
|
|
exit 1
|
|
}
|
|
|
|
trap 'on_error_exit "${FUNCNAME}" "${LINENO}"' ERR
|
|
echo "INFO: JSON configuration test init"
|
|
json_config_test_init
|
|
|
|
tgt_rpc save_config > ${configs_path[target]}
|
|
|
|
echo "INFO: shutting down applications..."
|
|
if [[ $SPDK_TEST_VHOST_INIT -eq 1 ]]; then
|
|
initiator_rpc save_config > ${configs_path[initiator]}
|
|
json_config_clear initiator
|
|
json_config_test_shutdown_app initiator
|
|
fi
|
|
|
|
json_config_clear target
|
|
json_config_test_shutdown_app target
|
|
|
|
echo "INFO: relaunching applications..."
|
|
json_config_test_start_app target --json ${configs_path[target]}
|
|
if [[ $SPDK_TEST_VHOST_INIT -eq 1 ]]; then
|
|
json_config_test_start_app initiator --json ${configs_path[initiator]}
|
|
fi
|
|
|
|
echo "INFO: Checking if target configuration is the same..."
|
|
$rootdir/test/json_config/json_diff.sh <(tgt_rpc save_config) "${configs_path[target]}"
|
|
if [[ $SPDK_TEST_VHOST_INIT -eq 1 ]]; then
|
|
echo "INFO: Checking if virtio initiator configuration is the same..."
|
|
$rootdir/test/json_config/json_diff.sh <(initiator_rpc save_config) "${configs_path[initiator]}"
|
|
fi
|
|
|
|
echo "INFO: changing configuration and checking if this can be detected..."
|
|
# Self test to check if configuration diff can be detected.
|
|
tgt_rpc bdev_malloc_delete MallocBdevForConfigChangeCheck
|
|
if $rootdir/test/json_config/json_diff.sh <(tgt_rpc save_config) "${configs_path[target]}" > /dev/null; then
|
|
echo "ERROR: intentional configuration difference not detected!"
|
|
false
|
|
else
|
|
echo "INFO: configuration change detected."
|
|
fi
|
|
|
|
json_config_test_fini
|
|
|
|
echo "INFO: Success"
|