SoftRoce does not implement enough queues for multiconnection tests and cause test pool failures. In case interface used for test is software emulated - reduce number of NVMf subsystems in test. Change-Id: I52cc78015e72603c487a5774b91c6bd4523326b0 Signed-off-by: Karol Latecki <karol.latecki@intel.com> Reviewed-on: https://review.gerrithub.io/392357 Tested-by: SPDK Automated Test System <sys_sgsw@intel.com> Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com> Reviewed-by: Jim Harris <james.r.harris@intel.com> Reviewed-by: Ben Walker <benjamin.walker@intel.com>
164 lines
3.0 KiB
Bash
Executable File
164 lines
3.0 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
|
|
NVMF_PORT=4420
|
|
NVMF_IP_PREFIX="192.168.100"
|
|
NVMF_IP_LEAST_ADDR=8
|
|
|
|
if [ -z "$NVMF_APP" ]; then
|
|
NVMF_APP=./app/nvmf_tgt/nvmf_tgt
|
|
fi
|
|
|
|
if [ -z "$NVMF_TEST_CORE_MASK" ]; then
|
|
NVMF_TEST_CORE_MASK=0xFFFF
|
|
fi
|
|
|
|
function load_ib_rdma_modules()
|
|
{
|
|
if [ `uname` != Linux ]; then
|
|
return 0
|
|
fi
|
|
|
|
modprobe ib_cm
|
|
modprobe ib_core
|
|
modprobe ib_ucm
|
|
modprobe ib_umad
|
|
modprobe ib_uverbs
|
|
modprobe iw_cm
|
|
modprobe rdma_cm
|
|
modprobe rdma_ucm
|
|
}
|
|
|
|
|
|
function detect_soft_roce_nics()
|
|
{
|
|
if hash rxe_cfg; then
|
|
rxe_cfg start
|
|
rdma_nics=$(get_rdma_if_list)
|
|
all_nics=$(ifconfig -s | awk '{print $1}')
|
|
all_nics=("${all_nics[@]/"Iface"}")
|
|
non_rdma_nics=$(echo "$rdma_nics $all_nics" | sort | uniq -u)
|
|
for nic in $non_rdma_nics; do
|
|
rxe_cfg add $nic || true
|
|
done
|
|
fi
|
|
}
|
|
|
|
function detect_mellanox_nics()
|
|
{
|
|
if ! hash lspci; then
|
|
return 0
|
|
fi
|
|
|
|
nvmf_nic_bdfs=`lspci | grep Ethernet | grep Mellanox | awk -F ' ' '{print "0000:"$1}'`
|
|
mlx_core_driver="mlx4_core"
|
|
mlx_ib_driver="mlx4_ib"
|
|
mlx_en_driver="mlx4_en"
|
|
|
|
if [ -z "$nvmf_nic_bdfs" ]; then
|
|
return 0
|
|
fi
|
|
|
|
# for nvmf target loopback test, suppose we only have one type of card.
|
|
for nvmf_nic_bdf in $nvmf_nic_bdfs
|
|
do
|
|
result=`lspci -vvv -s $nvmf_nic_bdf | grep 'Kernel modules' | awk -F ' ' '{print $3}'`
|
|
if [ "$result" == "mlx5_core" ]; then
|
|
mlx_core_driver="mlx5_core"
|
|
mlx_ib_driver="mlx5_ib"
|
|
mlx_en_driver=""
|
|
fi
|
|
break;
|
|
done
|
|
|
|
modprobe $mlx_core_driver
|
|
modprobe $mlx_ib_driver
|
|
if [ -n "$mlx_en_driver" ]; then
|
|
modprobe $mlx_en_driver
|
|
fi
|
|
|
|
# The mlx4 driver takes an extra few seconds to load after modprobe returns,
|
|
# otherwise ifconfig operations will do nothing.
|
|
sleep 5
|
|
}
|
|
|
|
function detect_rdma_nics()
|
|
{
|
|
detect_mellanox_nics
|
|
detect_soft_roce_nics
|
|
}
|
|
|
|
function allocate_nic_ips()
|
|
{
|
|
let count=$NVMF_IP_LEAST_ADDR
|
|
for nic_name in $(get_rdma_if_list); do
|
|
ip="$(get_ip_address $nic_name)"
|
|
if [ -z $ip ]; then
|
|
ifconfig $nic_name $NVMF_IP_PREFIX.$count netmask 255.255.255.0 up
|
|
let count=$count+1
|
|
fi
|
|
# dump configuration for debug log
|
|
ifconfig $nic_name
|
|
done
|
|
}
|
|
|
|
function get_available_rdma_ips()
|
|
{
|
|
for nic_name in $(get_rdma_if_list); do
|
|
ifconfig $nic_name | grep "inet " | awk '{print $2}'
|
|
done
|
|
}
|
|
|
|
function get_rdma_if_list()
|
|
{
|
|
for nic_type in `ls /sys/class/infiniband`; do
|
|
for nic_name in `ls /sys/class/infiniband/${nic_type}/device/net`; do
|
|
echo "$nic_name"
|
|
done
|
|
done
|
|
}
|
|
|
|
function get_ip_address()
|
|
{
|
|
interface=$1
|
|
ifconfig $interface | grep "inet " | awk '{print $2}' | sed 's/[^0-9\.]//g'
|
|
}
|
|
|
|
function nvmfcleanup()
|
|
{
|
|
sync
|
|
rmmod nvme-rdma
|
|
}
|
|
|
|
function rdma_device_init()
|
|
{
|
|
load_ib_rdma_modules
|
|
detect_rdma_nics
|
|
allocate_nic_ips
|
|
}
|
|
|
|
function revert_soft_roce()
|
|
{
|
|
if hash rxe_cfg; then
|
|
interfaces="$(ifconfig -s | awk '{print $1}')"
|
|
for interface in $interfaces; do
|
|
rxe_cfg remove $interface || true
|
|
done
|
|
rxe_cfg stop || true
|
|
fi
|
|
}
|
|
|
|
function check_ip_is_soft_roce()
|
|
{
|
|
IP=$1
|
|
if hash rxe_cfg; then
|
|
dev=$(ip -4 -o addr show | grep $IP | cut -d" " -f2)
|
|
if rxe_cfg | grep $dev; then
|
|
return 0
|
|
else
|
|
return 1
|
|
fi
|
|
else
|
|
return 1
|
|
fi
|
|
}
|