3704b949fa
This automates the process of probing some RDMA capable Chelsio NICs Change-Id: I1ef52ffd899d4cbd1ace65037c8acf0be099adae Signed-off-by: Seth Howell <seth.howell@intel.com> Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/446968 Tested-by: SPDK CI Jenkins <sys_sgci@intel.com> Reviewed-by: Jim Harris <james.r.harris@intel.com> Reviewed-by: Ben Walker <benjamin.walker@intel.com>
223 lines
4.1 KiB
Bash
Executable File
223 lines
4.1 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
|
|
NVMF_PORT=4420
|
|
NVMF_IP_PREFIX="192.168.100"
|
|
NVMF_IP_LEAST_ADDR=8
|
|
NVMF_TCP_IP_ADDRESS="127.0.0.1"
|
|
|
|
: ${NVMF_APP_SHM_ID="0"}; export NVMF_APP_SHM_ID
|
|
: ${NVMF_APP="./app/nvmf_tgt/nvmf_tgt -i $NVMF_APP_SHM_ID -e 0xFFFF"}; export NVMF_APP
|
|
|
|
have_pci_nics=0
|
|
|
|
function load_ib_rdma_modules()
|
|
{
|
|
if [ `uname` != Linux ]; then
|
|
return 0
|
|
fi
|
|
|
|
modprobe ib_cm
|
|
modprobe ib_core
|
|
# Newer kernels do not have the ib_ucm module
|
|
modprobe ib_ucm || true
|
|
modprobe ib_umad
|
|
modprobe ib_uverbs
|
|
modprobe iw_cm
|
|
modprobe rdma_cm
|
|
modprobe rdma_ucm
|
|
}
|
|
|
|
|
|
function detect_soft_roce_nics()
|
|
{
|
|
if hash rxe_cfg; then
|
|
rxe_cfg start
|
|
rdma_nics=$(get_rdma_if_list)
|
|
all_nics=$(ip -o link | awk '{print $2}' | cut -d":" -f1)
|
|
non_rdma_nics=$(echo -e "$rdma_nics\n$all_nics" | sort | uniq -u)
|
|
for nic in $non_rdma_nics; do
|
|
if [[ -d /sys/class/net/${nic}/bridge ]]; then
|
|
continue
|
|
fi
|
|
rxe_cfg add $nic || true
|
|
done
|
|
fi
|
|
}
|
|
|
|
|
|
# args 1 and 2 represent the grep filters for finding our NICS.
|
|
# subsequent args are all drivers that should be loaded if we find these NICs.
|
|
# Those drivers should be supplied in the correct order.
|
|
function detect_nics_and_probe_drivers()
|
|
{
|
|
NIC_VENDOR="$1"
|
|
NIC_CLASS="$2"
|
|
|
|
nvmf_nic_bdfs=`lspci | grep Ethernet | grep "$NIC_VENDOR" | grep "$NIC_CLASS" | awk -F ' ' '{print "0000:"$1}'`
|
|
|
|
if [ -z "$nvmf_nic_bdfs" ]; then
|
|
return 0
|
|
fi
|
|
|
|
have_pci_nics=1
|
|
if [ $# -ge 2 ]; then
|
|
# shift out the first two positional arguments.
|
|
shift 2
|
|
# Iterate through the remaining arguments.
|
|
for i; do
|
|
modprobe "$i"
|
|
done
|
|
fi
|
|
}
|
|
|
|
|
|
function detect_pci_nics()
|
|
{
|
|
|
|
if ! hash lspci; then
|
|
return 0
|
|
fi
|
|
|
|
detect_nics_and_probe_drivers "Mellanox" "ConnectX-4" "mlx4_core" "mlx4_ib" "mlx4_en"
|
|
detect_nics_and_probe_drivers "Mellanox" "ConnectX-5" "mlx5_core" "mlx5_ib"
|
|
detect_nics_and_probe_drivers "Intel" "X722" "i40e" "i40iw"
|
|
detect_nics_and_probe_drivers "Chelsio" "Unified Wire" "cxgb4" "iw_cxgb4"
|
|
|
|
if [ "$have_pci_nics" -eq "0" ]; then
|
|
return 0
|
|
fi
|
|
|
|
# Provide time for drivers to properly load.
|
|
sleep 5
|
|
}
|
|
|
|
function detect_rdma_nics()
|
|
{
|
|
detect_pci_nics
|
|
if [ "$have_pci_nics" -eq "0" ]; then
|
|
detect_soft_roce_nics
|
|
fi
|
|
}
|
|
|
|
function allocate_nic_ips()
|
|
{
|
|
let count=$NVMF_IP_LEAST_ADDR
|
|
for nic_name in $(get_rdma_if_list); do
|
|
ip="$(get_ip_address $nic_name)"
|
|
if [ -z $ip ]; then
|
|
ip addr add $NVMF_IP_PREFIX.$count/24 dev $nic_name
|
|
ip link set $nic_name up
|
|
let count=$count+1
|
|
fi
|
|
# dump configuration for debug log
|
|
ip addr show $nic_name
|
|
done
|
|
}
|
|
|
|
function get_available_rdma_ips()
|
|
{
|
|
for nic_name in $(get_rdma_if_list); do
|
|
get_ip_address $nic_name
|
|
done
|
|
}
|
|
|
|
function get_rdma_if_list()
|
|
{
|
|
for nic_type in `ls /sys/class/infiniband`; do
|
|
for nic_name in `ls /sys/class/infiniband/${nic_type}/device/net`; do
|
|
echo "$nic_name"
|
|
done
|
|
done
|
|
}
|
|
|
|
function get_ip_address()
|
|
{
|
|
interface=$1
|
|
ip -o -4 addr show $interface | awk '{print $4}' | cut -d"/" -f1
|
|
}
|
|
|
|
function nvmfcleanup()
|
|
{
|
|
sync
|
|
set +e
|
|
for i in {1..20}; do
|
|
modprobe -v -r nvme-rdma nvme-fabrics
|
|
if [ $? -eq 0 ]; then
|
|
set -e
|
|
return
|
|
fi
|
|
sleep 1
|
|
done
|
|
set -e
|
|
|
|
# So far unable to remove the kernel modules. Try
|
|
# one more time and let it fail.
|
|
modprobe -v -r nvme-rdma nvme-fabrics
|
|
}
|
|
|
|
function nvmftestinit()
|
|
{
|
|
if [ "$1" == "iso" ]; then
|
|
$rootdir/scripts/setup.sh
|
|
rdma_device_init
|
|
fi
|
|
}
|
|
|
|
function nvmftestfini()
|
|
{
|
|
if [ "$1" == "iso" ]; then
|
|
$rootdir/scripts/setup.sh reset
|
|
rdma_device_init
|
|
fi
|
|
}
|
|
|
|
function rdma_device_init()
|
|
{
|
|
load_ib_rdma_modules
|
|
detect_rdma_nics
|
|
allocate_nic_ips
|
|
}
|
|
|
|
function revert_soft_roce()
|
|
{
|
|
if hash rxe_cfg; then
|
|
interfaces="$(ip -o link | awk '{print $2}' | cut -d":" -f1)"
|
|
for interface in $interfaces; do
|
|
rxe_cfg remove $interface || true
|
|
done
|
|
rxe_cfg stop || true
|
|
fi
|
|
}
|
|
|
|
function check_ip_is_soft_roce()
|
|
{
|
|
IP=$1
|
|
if hash rxe_cfg; then
|
|
dev=$(ip -4 -o addr show | grep $IP | cut -d" " -f2)
|
|
if [ -z $(rxe_cfg | grep $dev | awk '{print $4}') ]; then
|
|
return 1
|
|
else
|
|
return 0
|
|
fi
|
|
else
|
|
return 1
|
|
fi
|
|
}
|
|
|
|
function nvme_connect()
|
|
{
|
|
local init_count=$(nvme list | wc -l)
|
|
|
|
nvme connect $@
|
|
if [ $? != 0 ]; then return $?; fi
|
|
|
|
for i in $(seq 1 10); do
|
|
if [ $(nvme list | wc -l) -gt $init_count ]; then
|
|
return 0
|
|
else
|
|
sleep 1s
|
|
fi
|
|
done
|
|
return 1
|
|
}
|