Chen Wang 104f7d8575 test/nvmf: add fio and lvol test cases with raid bdev
1. Add the raid bdevs which based two malloc bdevs into subsystem
   to run NVMf target fio case.
2. Create the lvol store with raid bdev which based two malloc bdevs
   when the number of subsystems is equal to 1.

Change-Id: Ia7dda4f1b99e259d1fd28b8856cc8c6e791e7720
Signed-off-by: Chen Wang <chenx.wang@intel.com>
Reviewed-on: https://review.gerrithub.io/422493
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Chandler-Test-Pool: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2018-09-25 04:18:15 +00:00

109 lines
2.9 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
set -e
# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization.
# e.g. sudo ./fio.sh iso
nvmftestinit $1
RDMA_IP_LIST=$(get_available_rdma_ips)
NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
if [ -z $NVMF_FIRST_TARGET_IP ]; then
echo "no NIC for nvmf test"
exit 0
fi
timing_enter fio
timing_enter start_nvmf_tgt
# Start up the NVMf target in another process
$NVMF_APP -m 0xF --wait-for-rpc &
nvmfpid=$!
trap "process_shm --id $NVMF_APP_SHM_ID; killprocess $nvmfpid; nvmftestfini $1; exit 1" SIGINT SIGTERM EXIT
waitforlisten $nvmfpid
$rpc_py set_nvmf_target_options -u 8192 -p 4
$rpc_py start_subsystem_init
timing_exit start_nvmf_tgt
malloc_bdevs="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE) "
malloc_bdevs+="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)"
# Create a RAID-0 bdev from two malloc bdevs
raid_malloc_bdevs="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE) "
raid_malloc_bdevs+="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)"
$rpc_py construct_raid_bdev -n raid0 -s 64 -r 0 -b "$raid_malloc_bdevs"
modprobe -v nvme-rdma
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
for malloc_bdev in $malloc_bdevs; do
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 "$malloc_bdev"
done
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s 4420
# Append the raid0 bdev into subsystem
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 raid0
nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
waitforblk "nvme0n1"
waitforblk "nvme0n2"
waitforblk "nvme0n3"
$testdir/nvmf_fio.py 4096 1 write 1 verify
$testdir/nvmf_fio.py 4096 1 randwrite 1 verify
$testdir/nvmf_fio.py 4096 128 write 1 verify
$testdir/nvmf_fio.py 4096 128 randwrite 1 verify
sync
#start hotplug test case
$testdir/nvmf_fio.py 4096 1 read 10 &
fio_pid=$!
sleep 3
set +e
$rpc_py destroy_raid_bdev "raid0"
for malloc_bdev in $malloc_bdevs; do
$rpc_py delete_malloc_bdev "$malloc_bdev"
done
wait $fio_pid
fio_status=$?
nvme disconnect -n "nqn.2016-06.io.spdk:cnode1" || true
if [ $fio_status -eq 0 ]; then
echo "nvmf hotplug test: fio successful - expected failure"
nvmfcleanup
killprocess $nvmfpid
exit 1
else
echo "nvmf hotplug test: fio failed as expected"
fi
set -e
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
rm -f ./local-job0-0-verify.state
rm -f ./local-job1-1-verify.state
rm -f ./local-job2-2-verify.state
trap - SIGINT SIGTERM EXIT
nvmfcleanup
killprocess $nvmfpid
nvmftestfini $1
timing_exit fio