numam-spdk/test/nvmf/host/target_disconnect.sh
Changpeng Liu f4d2ba4371 test/nvmf: use recommended nvmf_create_subsystem rpc
There are logs like below in existing CI tests:
"nvmf_subsystem_create is deprecated, use nvmf_create_subsystem instead."

Change-Id: Id257ab13120a71ad3d0ae7ed22ed6e0a4f005cf0
Signed-off-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7670
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Monica Kenguva <monica.kenguva@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2021-05-20 15:00:22 +00:00

84 lines
2.4 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
PLUGIN_DIR=$rootdir/examples/nvme/fio_plugin
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
function disconnect_init() {
nvmfappstart -m 0xF0
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $1 -s $NVMF_PORT
}
# Test to make sure we don't segfault or access null pointers when we try to connect to
# a discovery controller that doesn't exist yet.
function nvmf_target_disconnect_tc1() {
set +e
$SPDK_EXAMPLE_DIR/reconnect -q 32 -o 4096 -w randrw -M 50 -t 10 -c 0xF \
-r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT"
# If the program crashes, the high bit of $? will be set so we will get a value in the hundreds.
# But if the reconnect code detects errors and exits normally it will return 1.
if [ $? != 1 ]; then
set -e
exit 1
fi
set -e
}
function nvmf_target_disconnect_tc2() {
disconnect_init $NVMF_FIRST_TARGET_IP
# If perf doesn't shut down, this test will time out.
$SPDK_EXAMPLE_DIR/reconnect -q 32 -o 4096 -w randrw -M 50 -t 10 -c 0xF \
-r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT" &
reconnectpid=$!
sleep 2
kill -9 $nvmfpid
sleep 2
disconnect_init $NVMF_FIRST_TARGET_IP
wait $reconnectpid
sync
}
function nvmf_target_disconnect_tc3() {
$SPDK_EXAMPLE_DIR/reconnect -q 32 -o 4096 -w randrw -M 50 -t 10 -c 0xF \
-r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT alt_traddr:$NVMF_SECOND_TARGET_IP" &
reconnectpid=$!
sleep 2
kill -9 $nvmfpid
sleep 2
disconnect_init $NVMF_SECOND_TARGET_IP
wait $reconnectpid
sync
}
nvmftestinit
run_test "nvmf_target_disconnect_tc1" nvmf_target_disconnect_tc1
run_test "nvmf_target_disconnect_tc2" nvmf_target_disconnect_tc2
if [ -n "$NVMF_SECOND_TARGET_IP" ]; then
run_test "nvmf_target_disconnect_tc3" nvmf_target_disconnect_tc3
fi
trap - SIGINT SIGTERM EXIT
nvmftestfini