numam-spdk/etc/spdk/nvmf.conf.in
Gregory Shapiro 14032a984c NVMF: Add model number as parameter to construct_nvmf_subsystem (-d option).
Change-Id: Ia1a458a0ac1c5a17d2955a3f31c6dfe77538eb17
Signed-off-by: Gregory Shapiro <gregory.shapiro@kaminario.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/438562
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2019-04-23 16:51:16 +00:00

248 lines
8.6 KiB
Plaintext

# NVMf Target Configuration File
#
# Please write all parameters using ASCII.
# The parameter must be quoted if it includes whitespace.
#
# Configuration syntax:
# Leading whitespace is ignored.
# Lines starting with '#' are comments.
# Lines ending with '\' are concatenated with the next line.
# Bracketed ([]) names define sections
[Global]
# Tracepoint group mask for spdk trace buffers
# Default: 0x0 (all tracepoint groups disabled)
# Set to 0xFFFF to enable all tracepoint groups.
#TpointGroupMask 0x0
# PciBlacklist and PciWhitelist cannot be used at the same time
#PciBlacklist 0000:01:00.0
#PciBlacklist 0000:02:00.0
#PciWhitelist 0000:03:00.0
#PciWhitelist 0000:04:00.0
# Users may activate entries in this section to override default values for
# global parameters in the block device (bdev) subsystem.
[Bdev]
# Number of spdk_bdev_io structures allocated in the global bdev subsystem pool.
#BdevIoPoolSize 65536
# Maximum number of spdk_bdev_io structures to cache per thread.
#BdevIoCacheSize 256
# Users may change this section to create a different number or size of
# malloc LUNs.
# This will generate 8 LUNs with a malloc-allocated backend.
# Each LUN will be size 64MB and these will be named
# Malloc0 through Malloc7. Not all LUNs defined here are necessarily
# used below.
[Malloc]
NumberOfLuns 8
LunSizeInMB 64
# Users must change this section to match the /dev/sdX devices to be
# exported as iSCSI LUNs. The devices are accessed using Linux AIO.
# The format is:
# AIO <file name> <bdev name>
# The file name is the backing device
# The bdev name can be referenced from elsewhere in the configuration file.
# Block size may be omitted to automatically detect the block size of a disk.
[AIO]
AIO /dev/sdb AIO0
AIO /dev/sdc AIO1
AIO /tmp/myfile AIO2 4096
# PMDK libpmemblk-based block device
[Pmem]
# Syntax:
# Blk <pmemblk pool file name> <bdev name>
Blk /path/to/pmem-pool Pmem0
# Define NVMf protocol global options
[Nvmf]
# Set how often the acceptor polls for incoming connections. The acceptor is also
# responsible for polling existing connections that have gone idle. 0 means continuously
# poll. Units in microseconds.
AcceptorPollRate 10000
# One valid transport type must be set in each [Transport].
# The first is the case of RDMA transport and the second is the case of TCP transport.
[Transport]
# Set RDMA transport type.
Type RDMA
# Set the maximum number of outstanding I/O per queue.
#MaxQueueDepth 128
# Set the maximum number of submission and completion queues per session.
# Setting this to '8', for example, allows for 8 submission and 8 completion queues
# per session.
#MaxQueuesPerSession 4
# Set the maximum in-capsule data size. Must be a multiple of 16.
# 0 is a valid choice.
#InCapsuleDataSize 4096
# Set the maximum I/O size. Must be a multiple of 4096.
#MaxIOSize 131072
# Set the I/O unit size, and this value should not be larger than MaxIOSize
#IOUnitSize 131072
# Set the maximum number of IO for admin queue
#MaxAQDepth 32
# Set the number of pooled data buffers available to the transport
# It is used to provide the read/write data buffers for the qpairs on this transport.
#NumSharedBuffers 512
# Set the number of shared buffers to be cached per poll group
#BufCacheSize 32
# Set the maximum number outstanding I/O per shared receive queue. Relevant only for RDMA transport
#MaxSRQDepth 4096
[Transport]
# Set TCP transport type.
Type TCP
# Set the maximum number of outstanding I/O per queue.
#MaxQueueDepth 128
# Set the maximum number of submission and completion queues per session.
# Setting this to '8', for example, allows for 8 submission and 8 completion queues
# per session.
#MaxQueuesPerSession 4
# Set the maximum in-capsule data size. Must be a multiple of 16.
# 0 is a valid choice.
#InCapsuleDataSize 4096
# Set the maximum I/O size. Must be a multiple of 4096.
#MaxIOSize 131072
# Set the I/O unit size, and this value should not be larger than MaxIOSize
#IOUnitSize 131072
# Set the maximum number of IO for admin queue
#MaxAQDepth 32
# Set the number of pooled data buffers available to the transport
# It is used to provide the read/write data buffers for the qpairs on this transport.
#NumSharedBuffers 512
# Set the number of shared buffers to be cached per poll group
#BufCacheSize 32
[Nvme]
# NVMe Device Whitelist
# Users may specify which NVMe devices to claim by their transport id.
# See spdk_nvme_transport_id_parse() in spdk/nvme.h for the correct format.
# The second argument is the assigned name, which can be referenced from
# other sections in the configuration file. For NVMe devices, a namespace
# is automatically appended to each name in the format <YourName>nY, where
# Y is the NSID (starts at 1).
TransportID "trtype:PCIe traddr:0000:00:00.0" Nvme0
TransportID "trtype:PCIe traddr:0000:01:00.0" Nvme1
TransportID "trtype:PCIe traddr:0000:02:00.0" Nvme2
TransportID "trtype:PCIe traddr:0000:03:00.0" Nvme3
TransportID "trtype:RDMA adrfam:IPv4 traddr:192.168.100.8 trsvcid:4420 hostaddr:192.168.100.9 subnqn:nqn.2016-06.io.spdk:cnode1" Nvme4
TransportID "trtype:TCP adrfam:IPv4 traddr:192.168.100.3 trsvcid:4420 hostaddr:192.168.100.4 subnqn:nqn.2016-06.io.spdk:cnode2" Nvme5
# The number of attempts per I/O when an I/O fails. Do not include
# this key to get the default behavior.
RetryCount 4
# Timeout for each command, in microseconds. If 0, don't track timeouts.
TimeoutUsec 0
# Action to take on command time out. Only valid when Timeout is greater
# than 0. This may be 'Reset' to reset the controller, 'Abort' to abort
# the command, or 'None' to just print a message but do nothing.
# Admin command timeouts will always result in a reset.
ActionOnTimeout None
# Set how often the admin queue is polled for asynchronous events.
# Units in microseconds.
AdminPollRate 100000
# Set how often I/O queues are polled from completions.
# Units in microseconds.
IOPollRate 0
# Disable handling of hotplug (runtime insert and remove) events,
# users can set to Yes if want to enable it.
# Default: No
HotplugEnable No
# The Split virtual block device slices block devices into multiple smaller bdevs.
[Split]
# Syntax:
# Split <bdev> <count> [<size_in_megabytes>]
# Split Malloc2 into two equally-sized portions, Malloc2p0 and Malloc2p1
Split Malloc2 2
# Split Malloc3 into eight 1-megabyte portions, Malloc3p0 ... Malloc3p7,
# leaving the rest of the device inaccessible
Split Malloc3 8 1
# The RAID virtual block device based on pre-configured block device.
[RAID1]
# Unique name of this RAID device.
Name Raid0
# RAID level, only raid level 0 is supported.
RaidLevel 0
# Strip size in KB.
StripSize 64
# Number of pre-configured bdevs.
NumDevices 2
# Pre-configured bdevs name with Nvme.
Devices Nvme2n1 Nvme3n1
# Pre-configured bdevs name with Malloc.
#Devices Malloc0 Malloc1
# Pre-configured bdevs name with AIO.
#Devices AIO0 AIO1
# Define an NVMf Subsystem.
# - NQN is required and must be unique.
# - Between 1 and 255 Listen directives are allowed. This defines
# the addresses on which new connections may be accepted. The format
# is Listen <type> <address> where type currently can only be RDMA.
# - Between 0 and 255 Host directives are allowed. This defines the
# NQNs of allowed hosts. If no Host directive is specified, all hosts
# are allowed to connect.
# - Between 0 and 255 Namespace directives are allowed. These define the
# namespaces accessible from this subsystem.
# The user must specify MaxNamespaces to allow for adding namespaces
# during active connection. By default it is 0
# The user must specify a bdev name for each namespace, and may optionally
# specify a namespace ID. If nsid is omitted, the namespace will be
# assigned the next available NSID. The NSID must be unique within the
# subsystem. An optional namespace UUID may also be specified.
# Syntax:
# Namespace <bdev_name> [<nsid> [<uuid>]]
# Namespaces backed by physical NVMe devices
[Subsystem1]
NQN nqn.2016-06.io.spdk:cnode1
Listen TCP 15.15.15.2:4420
AllowAnyHost No
Host nqn.2016-06.io.spdk:init
SN SPDK00000000000001
MN SPDK_Controller1
MaxNamespaces 20
Namespace Nvme0n1 1
Namespace Nvme1n1 2
Namespace Raid0
# Multiple subsystems are allowed.
# Namespaces backed by non-NVMe devices
[Subsystem2]
NQN nqn.2016-06.io.spdk:cnode2
Listen RDMA 192.168.2.21:4420
AllowAnyHost No
Host nqn.2016-06.io.spdk:init
SN SPDK00000000000002
MN SPDK_Controller2
Namespace Malloc0
Namespace Malloc1
Namespace AIO0
Namespace AIO1